Semi-automated 96-well solid-phase extraction and gas chromatography-negative chemical ionization tandem mass spectrometry for the trace analysis of fluprostenol in rat plasma

被引:5
|
作者
Gauw, RD [1 ]
Stoffolano, PJ [1 ]
Kuhlenbeck, DL [1 ]
Patel, VS [1 ]
Garver, SM [1 ]
Baker, TR [1 ]
Wehmeyer, KR [1 ]
机构
[1] Procter & Gamble Pharmaceut, Mason, OH 45040 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 744卷 / 02期
关键词
fluprostenol;
D O I
10.1016/S0378-4347(00)00254-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS-MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC-NCI-MS-MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90-106% with a precision of 2.4-12.9%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 50 条
  • [11] Validation of a sensitive and automated 96-well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the determination of desloratadine and 3-hydroxydesloratadine in human plasma
    Yang, LY
    Clement, RP
    Kantesaria, B
    Reyderman, L
    Beaudry, F
    Grandmaison, C
    Di Donato, L
    Masse, R
    Rudewicz, PJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 229 - 240
  • [12] Validation and application of a 96-well format solid-phase extraction and liquid chromatography-tandem mass spectrometry method for the quantitation of digoxin in human plasma
    Hashimoto, Yoshitaka
    Shibakawa, Kimio
    Nakade, Susumu
    Miyata, Yasuyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 869 (1-2): : 126 - 132
  • [13] Determination of morphine and morphine glucuronides in human plasma by 96-well plate solid-phase extraction and liquid chromatography-electrospray ionization mass spectrometry
    Whittington, D
    Kharasch, ED
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01): : 95 - 103
  • [14] Determination of deltamethrin in rat plasma and brain using gas chromatography-negative chemical ionization mass spectrometry
    Gullick, Darren
    Popovici, Andrew
    Young, Holly C.
    Bruckner, James V.
    Cummings, Brian S.
    Li, Pei
    Bartlett, Michael G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 158 - 165
  • [15] Liquid chromatography/electrospray tandem mass spectrometry method for the quantitation of fosinoprilat in human serum using automated 96-well solid-phase extraction for sample preparation
    Jemal, M
    Huang, M
    Mao, Y
    Whigan, D
    Schuster, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (12) : 1023 - 1028
  • [16] Simultaneous determination of losartan, EXP-3174 and hydrochlorothiazide in plasma via fully automated 96-well-format-based solid-phase extraction and liquid chromatography-negative electrospray tandem mass spectrometry
    Kolocouri, Filomila
    Dotsikas, Yannis
    Apostolou, Constantinos
    Kousoulos, Constantinos
    Loukas, Yannis L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (02) : 593 - 601
  • [17] High-throughput analysis of everolimus (RAD001) and cyclosporin A (CsA) in whole blood by liquid chromatography/mass spectrometry using a semi-automated 96-well solid-phase extraction system
    McMahon, LM
    Luo, SY
    Hayes, M
    Tse, FLS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (21) : 1965 - 1971
  • [18] Analysis of aldehydes in excipients used in liquid/semi-solid formulations by gas chromatography-negative chemical ionization mass spectrometry
    Li, Zhong
    Kozlowski, Brian A.
    Chang, Emily P.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) : 299 - 305
  • [19] Quantitative determination of benazepril and benazeprilat in human plasma by gas chromatography-mass spectrometry using automated 96-well disk plate solid-phase extraction for sample preparation
    Pommier, F
    Boschet, F
    Gosset, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 783 (01): : 199 - 205
  • [20] Quantification of midazolam, morphine and metabolites in plasma using 96-well solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    Ahsman, Maurice J.
    van der Nagel, Bart C.
    Mathot, Ron A.
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 969 - 976