Ventilation optimization of solar greenhouse with removable back walls based on CFD

被引:77
作者
He, Xiangli
Wang, Jian [1 ]
Guo, Shirong
Zhang, Jian
Wei, Bin
Sun, Jin
Shu, Sheng
机构
[1] Nanjing Agr Univ, Coll Hort, Nanjing 210095, Jiangsu, Peoples R China
关键词
Greenhouse; Back wall vent; Ventilation; CFD simulation; Cooling effect; NATURAL VENTILATION; NUMERICAL-SIMULATION; MULTISPAN; EFFICIENCIES; PERFORMANCE; CLIMATE; SYSTEM; MODEL;
D O I
10.1016/j.compag.2017.10.001
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Ventilation is important for crop production and quality in greenhouse cultivation, and vent dimension and position are the basis of greenhouse design. In this study, the effect of the back wall vent dimension on solar greenhouse cooling was investigated by CFD (Computer Fluid Dynamics). The results showed that the average air temperature in a solar greenhouse with removable back walls (RG) was reduced by approximately 1.7 degrees C and the highest temperature dropped by approximately 5.8 degrees C compared with the traditional solar greenhouse with a brick back wall (TG). A 2-D CFD transient simulation model was developed to simulate the indoor temperature and airflow distributions in RGs with different back wall vent sizes. The results suggest that a back wall vent of 1.4 m increased inside the ventilation efficiency in a solar greenhouse with removable back walls.
引用
收藏
页码:16 / 25
页数:10
相关论文
共 44 条
  • [1] [Anonymous], 2006, THESIS
  • [2] Performance of a fog system for cooling greenhouses
    Arbel, A
    Yekutieli, O
    Barak, M
    [J]. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 72 (02): : 129 - 136
  • [3] Effect of vent arrangement on windward ventilation of a tunnel greenhouse
    Bartzanas, T
    Boulard, T
    Kittas, C
    [J]. BIOSYSTEMS ENGINEERING, 2004, 88 (04) : 479 - 490
  • [4] Efficacy of greenhouse natural ventilation: Environmental monitoring and CFD simulations of a study case
    Benni, Stefano
    Tassinari, Patrizia
    Bonora, Filippo
    Barbaresi, Alberto
    Torreggiani, Daniele
    [J]. ENERGY AND BUILDINGS, 2016, 125 : 276 - 286
  • [5] Numerical prediction of the effect of vent arrangements on the ventilation and energy transfer in a multi-span glasshouse using a bi-band radiation model
    Bournet, P. E.
    Khaoua, S. A. Ould
    Boulard, T.
    [J]. BIOSYSTEMS ENGINEERING, 2007, 98 (02) : 224 - 234
  • [6] Bournet PE, 2007, T ASABE, V50, P201, DOI 10.13031/2013.22401
  • [7] Effect of ventilator configuration on the distributed climate of greenhouses: A review of experimental and CFD studies
    Bournet, Pierre-Emmanuel
    Boulard, Thierry
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2010, 74 (02) : 195 - 217
  • [8] Cheng XiuHua Cheng XiuHua, 2011, Nongye Jixie Xuebao = Transactions of the Chinese Society for Agricultural Machinery, V42, P173
  • [9] Cheng XiuHua Cheng XiuHua, 2009, Nongye Jixie Xuebao = Transactions of the Chinese Society for Agricultural Machinery, V40, P179
  • [10] Numerical simulation of thermal behavior of a ventilated arc greenhouse during a solar day
    Fidaros, D. K.
    Baxevanou, C. A.
    Bartzanas, T.
    Kittas, C.
    [J]. RENEWABLE ENERGY, 2010, 35 (07) : 1380 - 1386