A Survey of Pediatric CT Protocols and Radiation Doses in South Korean Hospitals to Optimize the Radiation Dose for Pediatric CT Scanning

被引:22
作者
Hwang, Jae-Yeon [1 ,2 ,3 ]
Do, Kyung-Hyun [2 ,3 ]
Yang, Dong Hyun [2 ,3 ]
Cho, Young Ah [2 ,3 ]
Yoon, Hye-Kyung [4 ]
Lee, Jin Seong [2 ,3 ]
Koo, Hyun Jung [2 ,3 ]
机构
[1] Pusan Natl Univ, Yangsan Hosp, Dept Radiol, Res Inst Convergence Biomed Sci & Technol, Yangsan Si, Gyeongsannam Do, South Korea
[2] Univ Ulsan, Coll Med, Dept Radiol, 86 Asanbyeonwon Gil, Seoul 138736, South Korea
[3] Univ Ulsan, Coll Med, Res Inst Radiol, Seoul 138736, South Korea
[4] Kangwon Natl Univ Hosp, Dept Radiol, Chunchon, Gangwon Do, South Korea
关键词
DIAGNOSTIC REFERENCE LEVELS; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; PHANTOM SIZE; ABDOMINAL CT; CHILDREN; MDCT;
D O I
10.1097/MD.0000000000002146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Children are at greater risk of radiation exposure than adults because the rapidly dividing cells of children tend to be more radiosensitive and they have a longer expected life time in which to develop potential radiation injury. Some studies have surveyed computed tomography (CT) radiation doses and several studies have established diagnostic reference levels according to patient age or body size; however, no survey of CT radiation doses with a large number of patients has yet been carried out in South Korea. The aim of the present study was to investigate the radiation dose in pediatric CT examinations performed throughout South Korea. From 512 CT (222 brain CT, 105 chest CT, and 185 abdominopelvic CT) scans that were referred to our tertiary hospital, a dose report sheet was available for retrospective analysis of CT scan protocols and dose, including the volumetric CT dose index (CTDIvol), dose-length product (DLP), effective dose, and size-specific dose estimates (SSDE). At 55.2%, multiphase CT was the most frequently performed protocol for abdominopelvic CT. Tube current modulation was applied most often in abdominopelvic CT and chest CT, accounting for 70.1% and 62.7%, respectively. Regarding the CT dose, the interquartile ranges of the CTDIvol were 11.1 to 22.5 (newborns), 16.6 to 39.1 (<= 1 year), 14.6 to 41.7 (2-5 years), 23.5 to 44.1 (6-10 years), and 31.4 to 55.3 (<= 15 years) for brain CT; 1.3 to 5.7 (<= 1 year), 3.9 to 6.8 (2-5 years), 3.9 to 9.3 (6-10 years), and 7.7 to 13.8 (<= 15 years) for chest CT; and 4.0 to 7.5 (<= 1 year), 4.2 to 8.9 (2-5 years), 5.7 to 12.4 (6-10 years), and 7.6 to 16.6 (<= 15 years) for abdominopelvic CT. The SSDE and CTDIvol were well correlated for patients <5 years old, whereas the CTDIvol was lower in patients >= 6 years old. Our study describes the various parameters and dosimetry metrics of pediatric CT in South Korea. The CTDIvol, DLP, and effective dose were generally lower than in German and UK surveys, except in certain age groups.
引用
收藏
页数:9
相关论文
共 28 条
[1]  
American Association of Physicists in Medicine, 2011, 204 AAPM, V204, P1
[2]   Pediatric body MDCT: A 5-year follow-up survey of scanning parameters used by pediatric radiologists [J].
Arch, Michael E. ;
Frush, Donald P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (02) :611-617
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[5]   Use of Medical Imaging Procedures With Ionizing Radiation in Children A Population-Based Study [J].
Dorfman, Adam L. ;
Fazel, Reza ;
Einstein, Andrew J. ;
Applegate, Kimberly E. ;
Krumholz, Harlan M. ;
Wang, Yongfei ;
Christodoulou, Emmanuel ;
Chen, Jersey ;
Sanchez, Ramon ;
Nallamothu, Brahmajee K. .
ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 2011, 165 (05) :458-464
[6]   Radiation, Thoracic Imaging, and Children: Radiation Safety [J].
Frush, Donald P. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2011, 49 (05) :1053-+
[7]   CT dose and risk estimates in children. [J].
Frush D.P. .
Pediatric Radiology, 2011, 41 (Suppl 2) :483-487
[8]   Pediatric CT: practical approach to diminish the radiation dose [J].
Frush, DP .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :714-717
[9]  
Galanski M, 2007, ROFO-FORTSCHR RONTG, V179, P1110
[10]   Diagnostic Reference Ranges for Pediatric Abdominal CT [J].
Goske, Marilyn J. ;
Strauss, Keith J. ;
Coombs, Laura P. ;
Mandel, Keith E. ;
Towbin, Alexander J. ;
Larson, David B. ;
Callahan, Michael J. ;
Darge, Kassa ;
Podberesky, Daniel J. ;
Frush, Donald P. ;
Westra, Sjirk J. ;
Prince, Jeffrey S. .
RADIOLOGY, 2013, 268 (01) :208-218