Point of care and oral fluid hepatitis B testing in remote Indigenous communities of northern Australia

被引:6
作者
Sullivan, Richard P. [1 ,2 ,3 ]
Davies, Jane [1 ,2 ]
Binks, Paula [1 ]
Dhurrkay, Roslyn Gundjirryiir [1 ]
Gurruwiwi, George Garambaka [1 ]
Bukulatjpi, Sarah Mariyalawuy [4 ]
McKinnon, Melita [1 ]
Hosking, Kelly [1 ,5 ]
Littlejohn, Margaret [6 ]
Jackson, Kathy [6 ]
Locarnini, Stephen [6 ]
Davis, Joshua S. [1 ,7 ]
Tong, Steven Y. C. [1 ,8 ]
机构
[1] Charles Darwin Univ, Menzies Sch Hlth Res, Darwin, NT, Australia
[2] Royal Darwin Hosp, Dept Infect Dis, Casuarina, NT, Australia
[3] UNSW, Dept Infect Dis Immunol & Sexual Hlth, St George & Sutherland Clin Sch, Kogarah, NSW, Australia
[4] Miwatj Hlth Aboriginal Corp, East Arnhem, NT, Australia
[5] Northern Terr Govt, Top End Hlth Serv, Primary Hlth Care Branch, Darwin, NT, Australia
[6] Royal Melbourne Hosp, Peter Doherty Inst Infect & Immun, Victorian Infect Dis Res Lab, Melbourne, Vic, Australia
[7] John Hunter Hosp, New Lambton Hts, NSW, Australia
[8] Univ Melbourne, Victorian Infect Dis Serv, Royal Melbourne Hosp, Peter Doherty Inst Infect & Immun,Doherty Dept, Melbourne, Vic, Australia
基金
英国医学研究理事会;
关键词
diagnosis; hepatitis B; point of care testing; serologic tests; VIRUS SURFACE-ANTIGEN; C VIRUS; RAPID TESTS; DIAGNOSTIC-TESTS; INFECTION; HIV; PREVALENCE; SAMPLES; HBSAG; PERFORMANCE;
D O I
10.1111/jvh.13243
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Many Indigenous Australians in northern Australia living with chronic hepatitis B are unaware of their diagnosis due to low screening rates. A venous blood point of care test (POCT) or oral fluid laboratory test could improve testing uptake in this region. The purpose of this study was to assess the field performance of venous blood POCT and laboratory performance of an oral fluid hepatitis B surface antigen (HBsAg) test in Indigenous individuals living in remote northern Australian communities. The study was conducted with four very remote communities in the tropical north of Australia's Northern Territory. Community research workers collected venous blood and oral fluid samples. We performed the venous blood POCT for HBsAg in the field. We assessed the venous blood and oral fluid specimens for the presence of HBsAg using standard laboratory assays. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the POCT and oral fluid test, using serum laboratory detection of HBsAg as the gold standard. From 215 enrolled participants, 155 POCT and 197 oral fluid tests had corresponding serum HBsAg results. The POCT had a sensitivity of 91.7% and specificity of 100%. Based on a population prevalence of 6%, the PPV was 100% and NPV was 99.5%. The oral fluid test had a sensitivity of 56.8%, specificity of 98.1%, PPV of 97.3% and NPV of 65.9%. The venous blood POCT has excellent test characteristics and could be used to identify individuals with chronic HBV infection in high prevalence communities with limited access to health care. Oral fluid performance was suboptimal.
引用
收藏
页码:407 / 414
页数:8
相关论文
共 47 条
[1]   Diagnostic accuracy of tests to detect hepatitis B surface antigen: a systematic review of the literature and meta-analysis [J].
Amini, Ali ;
Varsaneux, Olivia ;
Kelly, Helen ;
Tang, Weiming ;
Chen, Wen ;
Boeras, Debrah I. ;
Falconer, Jane ;
Tucker, Joseph D. ;
Chou, Roger ;
Ishizaki, Azumi ;
Easterbrook, Philippa ;
Peeling, Rosanna W. .
BMC INFECTIOUS DISEASES, 2017, 17
[2]  
[Anonymous], 2017, WHO |
[3]  
Australia Government Department of Health, 2018, 3 NAT HEP B STRAT
[4]  
Australian Bureau of Statistics, 2016, REM STRUCT, V5
[5]  
Australian Government Department of Health, 2018, INF SYPH OUTBR
[6]  
Australian Government Geoscience Australia, AR AUSTR STAT TERR
[7]  
Australian Institute of Health and Welfare (AIHW), 2020, HLTH WELF AUSTR AB T
[8]  
Australian Institute of Health and Welfare (AIHW), 2010, CONTR CHRON DIS GAP
[9]   Performance of rapid tests for detection of HBsAg and anti-HBsAb in a large cohort, France [J].
Bottero, Julie ;
Boyd, Anders ;
Gozlan, Joel ;
Lemoine, Maud ;
Carrat, Fabrice ;
Collignon, Anne ;
Boo, Nicolas ;
Dhotte, Philippe ;
Varsat, Brigitte ;
Muller, Gerard ;
Cha, Olivier ;
Picard, Odile ;
Nau, Jean ;
Campa, Pauline ;
Silbermann, Benjamin ;
Bary, Marc ;
Girard, Pierre-Marie ;
Lacombe, Karine .
JOURNAL OF HEPATOLOGY, 2013, 58 (03) :473-478
[10]   The use of the OraSure® collection device for hepatitis virus testing in health care settings [J].
Cameron, Sheila O. ;
Carman, William E. .
JOURNAL OF CLINICAL VIROLOGY, 2005, 34 :S22-S28