Second-order advantage with excitation-emission fluorescence spectroscopy and a flow-through optosensing device. Simultaneous determination of thiabendazole and fuberidazole in the presence of uncalibrated interferences

被引:29
作者
Piccirilli, Gisela N. [1 ]
Escandar, Graciela M. [1 ]
机构
[1] Univ Nacl Rosario, Inst Quim Rosario CONICET UNR, Fac Ciencias Bioquim & Farmaceut, RA-2000 Rosario, Santa Fe, Argentina
关键词
PARTIAL LEAST-SQUARES; FLUOROMETRIC-DETERMINATION; MULTIVARIATE CALIBRATION; RESIDUAL BILINEARIZATION; PESTICIDES; WATER; PHOSPHORESCENCE; SPECTROMETRY; CARBENDAZIM; SAMPLES;
D O I
10.1039/b923565e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a novel approach for the simultaneous determination of two widely used fungicides in a very interfering environment, combining the advantage of a spectrofluorimetric optosensor coupled to a flow-injection system and the selectivity of second-order chemometric algorithms. The sensor is based on the simultaneous retention of thiabendazole and fuberidazole on C18-bonded phase placed inside a flow-cell. After the arrival of the analytes to the sensing zone, the flow is stopped and the excitation-emission fluorescence matrix is read in a fast-scanning spectrofluorimeter. Parallel factor analysis (PARAFAC) and unfolded and multidimensional partial least-squares coupled to residual bilinearization (U-and N-PLS/RBL) were selected for data processing. These algorithms achieve the second-order advantage, and are in principle able to overcome the problem of the presence of unexpected interferences. The power of U-PLS/RBL to quantify both fungicides at parts-per-billion levels, even in the presence of high concentrations of spectral interferences such as carbaryl, carbendazim and 1-naphthylacetic acid, is demonstrated. Indeed, U-PLS/RBL allowed us to reach selectivity using a commercial but non-selective sensing support. To the best of our knowledge, this is the first time the potentiality of the 'second-order advantage' is evaluated on a flow-injection system, using an unspecific supporting material and in the presence of three real interferences. Using a sample volume of 2 mL, detection limits of 4 ng mL(-1) and 0.3 ng mL(-1) for thiabendazole and fuberidazol were respectively obtained in samples without interferences. In samples containing interferences, the limits of detection were 17 and 1 ng mL(-1) for thiabendazole and fuberidazol, respectively. The sample frequency, including excitation/emission fluorescence matrix measurements, was 12 samples h(-1). The sensor was satisfactorily applied to the determination of both analytes in real water samples.
引用
收藏
页码:1299 / 1308
页数:10
相关论文
共 47 条
[1]   Determination of pesticides and their degradation products in soil:: critical review and comparison of methods [J].
Andreu, V ;
Picó, Y .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (10-11) :772-789
[2]   Screening of oil samples on the basis of excitation-emission room-temperature phosphorescence data and multiway chemometric techniques. Introducing the second-order advantage in a classification study [J].
Arancibia, Juan A. ;
Boschetti, Carlos E. ;
Olivieri, Alejandro C. ;
Escandar, Graciela M. .
ANALYTICAL CHEMISTRY, 2008, 80 (08) :2789-2798
[3]   Second-order advantage achieved by unfolded-partial least-squares/residual bilinearization modeling of excitation-emission fluorescence data presenting inner filter effects [J].
Bohoyo Gil, Diego ;
Munoz de la Pena, Arsenio ;
Arancibia, Juan A. ;
Escandar, Graciela M. ;
Olivieri, Alejandro C. .
ANALYTICAL CHEMISTRY, 2006, 78 (23) :8051-8058
[4]   THEORY OF ANALYTICAL-CHEMISTRY [J].
BOOKSH, KS ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1994, 66 (15) :A782-A791
[5]   Chemometrics-Assisted Excitation-Emission Fluorescence Spectroscopy on Nylon Membranes. Simultaneous Determination of Benzo[a]pyrene and Dibenz[a,h]anthracene at Parts-Per-Trillion Levels in the Presence of the Remaining EPA PAH Priority Pollutants As Interferences [J].
Bortolato, Santiago A. ;
Arancibia, Juan A. ;
Escandar, Graciela M. .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8276-8286
[6]   Recent development in optical chemical sensors coupling with flow injection analysis [J].
Bosch Ojeda, Catalina ;
Sanchez Rojas, Fuensanta .
SENSORS, 2006, 6 (10) :1245-1307
[7]   A new efficient method for determining the number of components in PARAFAC models [J].
Bro, R ;
Kiers, HAL .
JOURNAL OF CHEMOMETRICS, 2003, 17 (05) :274-286
[8]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[9]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.0.CO
[10]  
2-C