Ergonomics of disposable handles for minimally invasive surgery

被引:24
作者
Buechel, D. [1 ]
Marvik, R. [2 ]
Hallabrin, B. [1 ]
Matern, U. [1 ]
机构
[1] Univ Tubingen Hosp, Expt OR & Ergon, D-72072 Tubingen, Germany
[2] Norwegian Univ Sci & Technol NTNU, St Olavs Hosp, Natl Ctr Adv Laparoscop Surg, Trondheim, Norway
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2010年 / 24卷 / 05期
关键词
Ergonomics; Handle; Human factors; IEC; 62366; Laparoscopy; Patient safety; Surgery; Surgical instruments; Usability; LAPAROSCOPIC INSTRUMENT HANDLES; DESIGN; THUMB; RESPECT; ANGLE;
D O I
10.1007/s00464-009-0714-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
The ergonomic deficiencies of currently available minimally invasive surgery (MIS) instrument handles have been addressed in many studies. In this study, a new ergonomic pistol handle concept, realized as a prototype, and two disposable ring handles were investigated according to ergonomic properties set by new European standards. In this study, 25 volunteers performed four practical tasks to evaluate the ergonomics of the handles used in standard operating procedures (e.g., measuring a suture and cutting to length, precise maneuvering and targeting, and dissection of a gallbladder). Moreover, 20 participants underwent electromyography (EMG) tests to measure the muscle strain they experienced while carrying out the basic functions (grasp, rotate, and maneuver) in the x, y, and z axes. The data measured included the number of errors, the time required for task completion, perception of pressure areas, and EMG data. The values for usability in the test were effectiveness, efficiency, and user satisfaction. Surveys relating to the subjective rating were completed after each task for each of the three handles tested. Each handle except the new prototype caused pressure areas and pain. Extreme differences in muscle strain could not be observed for any of the three handles. Experienced surgeons worked more quickly with the prototype when measuring and cutting a suture (similar to 20%) and during precise maneuvering and targeting (similar to 20%). On the other hand, they completed the dissection task faster with the handle manufactured by Ethicon. Fewer errors were made with the prototype in dissection of the gallbladder. In contrast to the handles available on the market, the prototype was always rated as positive by the volunteers in the subjective surveys. None of the handles could fulfil all of the requirements with top scores. Each handle had its advantages and disadvantages. In contrast to the ring handles, the volunteers could fulfil most of the tasks more efficiently using the prototype handle without any remarkable pressure areas, cramps, or pain.
引用
收藏
页码:992 / 1004
页数:13
相关论文
共 29 条
[1]  
[Anonymous], 2006, 25062 ISOIEC
[2]   A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp [J].
Berguer, R ;
Gerber, S ;
Kilpatrick, G ;
Remler, M ;
Beckley, D .
ERGONOMICS, 1999, 42 (12) :1634-1645
[3]   The effect of laparoscopic instrument working angle on surgeons' upper extremity workload [J].
Berguer, R ;
Forkey, DL ;
Smith, WD .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (09) :1027-1029
[4]   An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper [J].
Berguer, R ;
Gerber, S ;
Kilpatrick, G ;
Beckley, D .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 1998, 12 (06) :805-808
[5]  
Delagi E. F., 1989, ELEKTROMYOGRAPHIE EX
[6]   Rocker handle for endoscopic needle drivers - Technical and ergonomic evaluation by infrared motion analysis system [J].
Emam, TA ;
Frank, TG ;
Hanna, GB ;
Stockham, G ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (07) :658-661
[7]   Influence of handle design on the surgeon's upper limb movements, muscle recruitment, and fatigue during endoscopic suturing [J].
Emam, TA ;
Frank, TG ;
Hanna, GB ;
Cuschieri, A .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2001, 15 (07) :667-672
[8]  
*EN IEC, 2007, 62366ED EN IEC
[9]   Optimal port locations for endoscopic intracorporeal knotting [J].
Hanna, GB ;
Shimi, S ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (04) :397-401
[10]   Neuropraxia following laparoscopic procedures: An occupational injury [J].
Horgan, LF ;
ORiordan, DC ;
Doctor, N .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (01) :33-35