Clinical feasibility of panintestinal (or panenteric) capsule endoscopy: a systematic review

被引:24
作者
Cortegoso Valdivia, Pablo [1 ]
Elosua, Alfonso [2 ]
Houdeville, Charles [3 ]
Pennazio, Marco [4 ]
Fernandez-Urien, Ignacio [5 ]
Dray, Xavier [3 ]
Toth, Ervin [6 ]
Eliakim, Rami [7 ]
Koulaouzidis, Anastasios [8 ]
机构
[1] Univ Parma, Univ Hosp Parma, Gastroenterol & Endoscopy Unit, Viale A Gramsci 14, I-43126 Parma, Italy
[2] Hosp Garcia Orcoyen, Gastroenterol Unit, Estella, Spain
[3] Sorbonne Univ, Ctr Endoscopie Digest, Hop St Antoine, AP HP, Paris, France
[4] Univ Turin, Univ Div Gastroenterol, AOU Citta Salute & Sci, Turin, Italy
[5] Complejo Hosp Navarra, Dept Gastroenterol, Pamplona, Spain
[6] Lund Univ, Skane Univ Hosp, Dept Gastroenterol, Malmo, Sweden
[7] Tel Aviv Univ, Sackler Sch Med, Chaim Sheba Med Ctr, Dept Gastroenterol, Tel Aviv, Israel
[8] Pomeranian Med Univ, Dept Social Med & Publ Hlth, Szczecin, Poland
关键词
capsule endoscopy; double-headed capsule; panenteric; panintestinal; CROHNS-DISEASE PATIENTS; PILLCAM COLON CAPSULE; DIAGNOSTIC YIELD; MULTICENTER; EVALUATE; 2(C);
D O I
10.1097/MEG.0000000000002200
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
In recent years, panintestinal capsule endoscopy (PCE) with double-headed capsules has been used to perform complete, single-sitting exploration of both small bowel and colon in different clinical conditions. Double-headed capsules for colonic examination (CCE) have been exploited first in this setting, followed by newer generations of capsules (i.e. PillCam Crohn, PCC) specifically engineered for this purpose. The aim of this study was to evaluate the feasibility of PCE in the form of a systematic review. We performed a comprehensive literature search to identify papers in which CE was specifically used for a PCE of the gastrointestinal tract. Data on CE, bowel preparation regimen, rate of cleanliness and completeness, and data on transit times were analyzed. The primary outcome was to assess the feasibility of a whole-gut exploration with CE. Sixteen (n = 16) studies including 915 CE procedures with CCE1 (n = 134), CCE2 (n = 357) and PCC (n = 424) were included. 13/16 studies were performed in the setting of Crohn's disease. Cleanliness and completeness rates were acceptable in all studies, ranging from 63.9% and 68.6% to 100%, respectively. In conclusion, PCE is a feasible technique, although further structured studies are needed to explore its full potential.
引用
收藏
页码:949 / 955
页数:7
相关论文
共 34 条
[1]   CECDAIic - a new useful tool in pan-intestinal evaluation of Crohn's disease patients in the era of mucosal healing [J].
Arieira, Catia ;
Magalhaes, Rui ;
de Castro, Francisca Dias ;
Carvalho, Pedro Boal ;
Rosa, Bruno ;
Moreira, Maria Joao ;
Cotter, Jose .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2019, 54 (11) :1326-1330
[2]  
Bjoersum-Meyer T., 2021, ENDOSCOPY, V53, pS194
[3]   Panenteric capsule endoscopy versus ileocolonoscopy plus magnetic resonance enterography in Crohn's disease: a multicentre, prospective study [J].
Bruining, David Henry ;
Oliva, Salvatore ;
Fleisher, Mark R. ;
Fischer, Monika ;
Fletcher, Joel G. .
BMJ OPEN GASTROENTEROLOGY, 2020, 7 (01)
[4]   Pan-enteric capsule for bleeding high-risk patients. Can we limit endoscopies? [J].
Carretero, Cristina ;
Prieto de Frias, Cesar ;
Angos, Ramon ;
Betes, Maite ;
Herraiz, Maite ;
de la Riva, Susana ;
Zozaya, Francisco ;
Fernandez-Calderon, Maria ;
Rodriguez-Lago, Iago ;
Munoz-Navas, Miguel .
REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2021, 113 (08) :580-584
[5]   PillCam COLON 2(C) in Crohn's disease: A new concept of pan-enteric mucosal healing assessment [J].
Carvalho, Pedro Boal ;
Rosa, Bruno ;
de Castro, Francisca Dias ;
Moreira, Maria Joao ;
Cotter, Jose .
WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (23) :7233-7241
[6]   Capsule endoscopy transit-related indicators in choosing the insertion route for double-balloon enteroscopy: a systematic review [J].
Cortegoso Valdivia, Pablo ;
Skonieczna-Zydecka, Karolina ;
Pennazio, Marco ;
Rondonotti, Emanuele ;
Marlicz, Wojciech ;
Toth, Ervin ;
Koulaouzidis, Anastasios .
ENDOSCOPY INTERNATIONAL OPEN, 2021, 09 (02) :E163-E170
[7]   Prospective evaluation of third-generation small bowel capsule endoscopy videos by independent readers demonstrates poor reproducibility of cleanliness classifications [J].
Dray, Xavier ;
Houist, Guy ;
Le Mouel, Jean-Philippe ;
Saurin, Jean-Christophe ;
Vanbiervliet, Geoffroy ;
Leandri, Chloe ;
Rahmi, Gabriel ;
Duburque, Clotilde ;
Kirchgesner, Julien ;
Leenhardt, Romain ;
Cholet, Franck ;
Quenehervej, Lucille .
CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2021, 45 (06)
[8]   Artificial intelligence in small bowel capsule endoscopy - current status, challenges and future promise [J].
Dray, Xavier ;
Iakovidis, Dimitris ;
Houdeville, Charles ;
Jover, Rodrigo ;
Diamantis, Dimitris ;
Histace, Aymeric ;
Koulaouzidis, Anastasios .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 (01) :12-19
[9]   Evaluation of the PillCam Colon capsule in the detection of colonic pathology: results of the first multicenter, prospective, comparative study [J].
Eliakim, R. ;
Fireman, Z. ;
Gralnek, I. M. ;
Yassin, K. ;
Waterman, M. ;
Kopelman, Y. ;
Lachter, J. ;
Koslowsky, B. ;
Adler, S. N. .
ENDOSCOPY, 2006, 38 (10) :963-970
[10]   Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy [J].
Eliakim, R. ;
Yassin, K. ;
Niv, Y. ;
Metzger, Y. ;
Lachter, J. ;
Gal, E. ;
Sapoznikov, B. ;
Konikoff, F. ;
Leichtmann, G. ;
Fireman, Z. ;
Kopelman, Y. ;
Adler, S. N. .
ENDOSCOPY, 2009, 41 (12) :1026-1031