Computational and Phantom-Based Feasibility Study of 3D dcNCI With Ultra-Low-Field MRI

被引:1
|
作者
Hofner, Nora [1 ]
Storm, Jan-Hendrik [1 ]
Hommen, Peter [1 ]
Cassara, Antonino Mario [2 ]
Korber, Rainer [1 ]
机构
[1] Phys Tech Bundesanstalt, Berlin, Germany
[2] Fdn Res Informat Technol Soc ITIS, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
ultra-low-field magnetic resonance imaging; neuronal current imaging; current dipole phantom; MEG; simulation; NEURONAL MAGNETIC-FIELDS; MICROTESLA MRI; HUMAN BRAIN; CURRENTS; SYSTEM; SIGNAL; NMR;
D O I
10.3389/fphy.2021.647376
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The possibility to directly and non-invasively localize neuronal activities in the human brain, as for instance by performing neuronal current imaging (NCI) via magnetic resonance imaging (MRI), would be a breakthrough in neuroscience. In order to assess the feasibility of 3-dimensional (3D) NCI, comprehensive computational and physical phantom experiments using low-noise ultra-low-field (ULF) MRI technology were performed using two different source models within spherical phantoms. The source models, consisting of a single dipole and an extended dipole grid, were calibrated enabling the quantitative emulation of a long-lasting neuronal activity by the application of known current waveforms. The dcNCI experiments were also simulated by solving the Bloch equations using the calculated internal magnetic field distributions of the phantoms and idealized MRI fields. The simulations were then validated by physical phantom experiments using a moderate polarization field of 17 mT. A focal activity with an equivalent current dipole of about 150 nAm and a physiologically relevant depth of 35 mm could be resolved with an isotropic voxel size of 25 mm. The simulation tool enabled the optimization of the imaging parameters for sustained neuronal activities in order to predict maximum sensitivity.
引用
收藏
页数:14
相关论文
共 22 条
  • [1] An advanced phantom study assessing the feasibility of neuronal current imaging by ultra-low-field NMR
    Koerber, Rainer
    Nieminen, Jaakko O.
    Hoefner, Nora
    Jazbinsek, Vojko
    Scheer, Hans-Juergen
    Kim, Kiwoong
    Burghoff, Martin
    JOURNAL OF MAGNETIC RESONANCE, 2013, 237 : 182 - 190
  • [2] SQUID-sensor-based ultra-low-field MRI calibration with phantom images: Towards quantitative imaging
    Dabek, Juhani
    Vesanen, Panu T.
    Zevenhoven, Koos C. J.
    Nieminen, Jaakko O.
    Sepponen, Raimo
    Ilmoniemi, Risto J.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 224 : 22 - 31
  • [3] Optimized 3D co-registration of ultra-low-field and high-field magnetic resonance images
    Guidotti, Roberto
    Sinibaldi, Raffaele
    De Luca, Cinzia
    Conti, Allegra
    Ilmoniemi, Risto J.
    Zevenhoven, Koos C. J.
    Magnelind, Per E.
    Pizzella, Vittorio
    Del Gratta, Cosimo
    Romani, Gian Luca
    Della Penna, Stefania
    PLOS ONE, 2018, 13 (03):
  • [4] Hybrid ultra-low-field MRI and magnetoencephalography system based on a commercial whole-head neuromagnetometer
    Vesanen, Panu T.
    Nieminen, Jaakko O.
    Zevenhoven, Koos C. J.
    Dabek, Juhani
    Parkkonen, Lauri T.
    Zhdanov, Andrey V.
    Luomahaara, Juho
    Hassel, Juha
    Penttila, Jari
    Simola, Juha
    Ahonen, Antti I.
    Makela, Jyrki P.
    Ilmoniemi, Risto J.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (06) : 1795 - 1804
  • [5] Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments
    Li, Bo
    Dong, Hui
    Huang, Xiao-Lei
    Qiu, Yang
    Tao, Quan
    Zhu, Jian-Ming
    CHINESE PHYSICS B, 2018, 27 (02)
  • [6] Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID:Simulations and experiments
    李波
    董慧
    黄小磊
    邱阳
    陶泉
    朱建明
    Chinese Physics B, 2018, 27 (02) : 277 - 283
  • [7] 4D Monte Carlo dose calculations for pre-treatment quality assurance of VMAT SBRT: a phantom-based feasibility study
    Roberts, Natalia F.
    Williams, Matthew
    Holloway, Lois
    Metcalfe, Peter
    Oborn, Bradley M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [8] COMPUTATIONAL STUDY OF SOLVENT BASED EXTRUSION 3D PRINTING
    Rath, Usharani
    Pandey, Pulak Mohan
    PROCEEDINGS OF THE ASME 2020 15TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE (MSEC2020), VOL 1A, 2020,
  • [9] Image based meshing of packed beds of cylinders at low aspect ratios using 3d MRI coupled with computational fluid dynamics
    Baker, M. J.
    Young, P. G.
    Tabor, G. R.
    COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (10) : 1969 - 1977
  • [10] Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy
    Paganelli, Chiara
    Lee, Danny
    Kipritidis, John
    Whelan, Brendan
    Greer, Peter B.
    Baroni, Guido
    Riboldi, Marco
    Keall, Paul
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (03) : 389 - 400