Visual Impact of Zernike and Seidel Forms of Monochromatic Aberrations

被引:87
作者
Cheng, Xu [1 ,2 ]
Bradley, Arthur [1 ]
Ravikumar, Sowmya [1 ]
Thibos, Larry N. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
[2] Vistakon Corp, Jacksonville, FL USA
关键词
monochromatic aberrations; visual acuity; Zernike; Seidel; retinal image quality; WAVE-FRONT ABERRATIONS; HIGHER-ORDER ABERRATIONS; CONTRAST SENSITIVITY; SPHERICAL-ABERRATION; REFRACTIVE ERRORS; IMAGE QUALITY; PSYCHOMETRIC FUNCTION; OPTICAL ABERRATIONS; ACUITY; EYES;
D O I
10.1097/OPX.0b013e3181d95217
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The aim of this study was to examine the impact of different aberrations modes (e. g., coma, astigmatism, spherical aberration [ SA]) and different aberration basis functions (Zernike or Seidel) on visual acuity (VA). Methods. Computational optics was used to generate retinal images degraded by either the Zernike or Seidel forms of second through fourth-order aberrations for an eye with a 5-mm pupil diameter. High contrast, photopic VA was measured using method of constant stimuli for letters displayed on a computer-controlled, linearized, quasimonochromatic (lambda = 556 nm) display. Results. Minimum angle of resolution (MAR) varied linearly with the magnitude (root mean square error) of all modes of aberration. The impact of individual Zernike lower-and higher-order aberrations (HOAs) varied significantly with mode, e. g., arc minutes of MAR per micrometer of root mean square slopes varied from 7 (spherical defocus) to 0.5 (quadrafoil). Seidel forms of these aberrations always had a smaller visual impact. Notably, Seidel SA had 1/17th the impact of Zernike SA with the same wavefront variance, and about 1/4th the impact of Zernike SA with matching levels of r(4) wavefront error. With lower-order components removed, HOAs near the center of the Zernike pyramid do not have a large visual impact. Conclusions. The majority of the visual impact of high levels of fourth-order Zernike aberrations can be attributed to the second-order terms within these polynomials. Therefore, the impact of SA can be minimized by balancing it with a defocus term that flattens the central wavefront (paraxial focus) or maximizes the area of the pupil with a flat wavefront. Over this wide range of aberration types and levels, image quality metrics based on the Point Spread Function (PSF) and Optical Transfer Function (OTF) can predict VA as reliably as VA measures can predict retests of VA, and, thus, such metrics may become valuable predictors of both VA and, via optimization, refractions. (Optom Vis Sci 2010; 87: 300-312)
引用
收藏
页码:300 / 312
页数:13
相关论文
共 65 条
[1]   Visual acuity and contrast sensitivity for individual Sloan letters [J].
Alexander, KR ;
Xie, W ;
Derlacki, DJ .
VISION RESEARCH, 1997, 37 (06) :813-819
[2]   Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction [J].
Alió, JL ;
Shabayek, MH ;
Belda, JI ;
Correas, P ;
Feijoo, ED .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :756-761
[3]   Interaction between aberrations to improve or reduce visual performance [J].
Applegate, RA ;
Marsack, JD ;
Ramos, R ;
Sarver, EJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (08) :1487-1495
[4]  
Applegate RA, 2000, J REFRACT SURG, V16, P507
[5]   Visual acuity as a function of Zernike mode and level of root mean square error [J].
Applegate, RA ;
Ballentine, C ;
Gross, H ;
Sarver, EJ ;
Sarver, CA .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (02) :97-105
[6]   Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity [J].
Applegate, Raymond A. ;
Marsack, Jason D. ;
Thibos, Larry N. .
OPTOMETRY AND VISION SCIENCE, 2006, 83 (09) :635-640
[7]   EFFECTS OF SPHERICAL AND ASTIGMATIC DEFOCUS ON ACUITY AND CONTRAST SENSITIVITY - A COMPARISON OF 3 CLINICAL CHARTS [J].
BRADLEY, A ;
THOMAS, T ;
KALAHER, M ;
HOERRES, M .
OPTOMETRY AND VISION SCIENCE, 1991, 68 (06) :418-426
[8]   SUBJECTIVE AND OBJECTIVE ASSESSMENT OF SOFT BIFOCAL CONTACT-LENS PERFORMANCE [J].
BULLIMORE, MA ;
JACOBS, RJ .
OPTOMETRY AND VISION SCIENCE, 1993, 70 (06) :469-475
[9]   EFFECTS OF THE SEIDEL ABERRATIONS ON VISUAL TARGET DISCRIMINATION [J].
BURTON, GJ ;
HAIG, ND .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (04) :373-385
[10]   Contrast Sensitivity Evaluation of Aspheric and Spherical Intraocular Lenses 2 Years After Implantation [J].
Caporossi, Aldo ;
Casprini, Fabrizio ;
Martone, Gianluca ;
Balestrazzi, Angelo ;
Tosi, Gian Marco ;
Ciompi, Leonardo .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (07) :578-590