Thyroid dose from common head and neck CT examinations in children: is there an excess risk for thyroid cancer induction?

被引:128
作者
Mazonakis, Michalis
Tzedakis, Antonis
Damilakis, John
Gourtsoyiannis, Nicholas
机构
[1] Univ Hosp Iraklion, Dept Phys Med, Div Radiol, Iraklion 71110, Crete, Greece
[2] Univ Crete, Fac Med, Dept Phys Med, Iraklion 71110, Crete, Greece
[3] Univ Crete, Fac Med, Dept Radiol, Iraklion 71110, Crete, Greece
关键词
computed tomography; children; thyroid dose; cancer risk;
D O I
10.1007/s00330-006-0417-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was conducted to estimate thyroid dose and the associated risk for thyroid cancer induction from common head and neck computed tomography (CT) examinations during childhood. The Monte Carlo N-particle transport code was employed to simulate the routine CT scanning of the brain, paranasal sinuses, inner ear and neck performed on sequential and/or spiral modes. The mean thyroid dose was calculated using mathematical phantoms representing a newborn infant and children of 1year, 5 years, 10 years and 15 years old. To verify Monte Carlo results, dose measurements were carried out on physical anthropomorphic phantoms using thermoluminescent dosemeters (TLDs). The scattered dose to thyroid from head CT examinations varied from 0.6 mGy to 8.7 mGy depending upon the scanned region, the pediatric patient's age and the acquisition mode used. Primary irradiation of the thyroid gland during CT of the neck resulted in an absorbed dose range of 15.2-52.0 mGy. The mean difference between Monte Carlo calculations and TLD measurements was 11.8%. Thyroid exposure to scattered radiation from head CT scanning is associated with a low but not negligible risk of cancer induction of 4-65 per million patients. Neck CT can result in an increased risk for development of thyroid malignancies up to 390 per million patients.
引用
收藏
页码:1352 / 1357
页数:6
相关论文
共 18 条
[1]  
[Anonymous], ICRP PUBL
[2]  
[Anonymous], 1985, NCRP PUBL, V7910
[3]   Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization [J].
Bacher, K ;
Bogaert, E ;
Lapere, R ;
De Wolf, D ;
Thierens, H .
CIRCULATION, 2005, 111 (01) :83-89
[4]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[5]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[6]  
Eckerman K.F., 1996, ORNL MATH PHANTOM SE
[7]   NORMALIZED PEDIATRIC ORGAN-ABSORBED DOSES FROM CT EXAMINATIONS [J].
FEARON, T ;
VUCICH, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :171-174
[8]  
Hall EJ., 2000, RADIOBIOLOGY RADIOLO
[9]   Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program [J].
Hohl, C. ;
Muehlenbruch, G. ;
Wildberger, J. E. ;
Leidecker, C. ;
Suss, C. ;
Schmidt, T. ;
Guenther, R. W. ;
Mahnken, A. H. .
EUROPEAN RADIOLOGY, 2006, 16 (08) :1841-1846
[10]  
International Commission on Radiological Protection, 2000, ICRP PUBL, V87