Cell-based fluorescent microsphere incorporated with carbon dots as a sensitive immunosensor for the rapid detection of Escherichia coli O157 in milk

被引:61
作者
Zhao, Yong [1 ,2 ]
Li, Yanzhao [2 ]
Zhang, Pingping [1 ,2 ]
Yan, Ziheng [1 ,2 ]
Zhou, Yugui [1 ,2 ]
Du, Yipu [1 ,2 ]
Qu, Chunyu [2 ]
Song, Yajun [1 ,2 ]
Zhou, Ding [3 ]
Qu, Songnan [4 ]
Yang, Ruifu [1 ,2 ]
机构
[1] Beijing Inst Microbiol & Epidemiol, State Key Lab Pathogen & Biosecur, Beijing 100071, Peoples R China
[2] Beijing Key Lab POCT Bioemergency & Clin, Beijing 100071, Peoples R China
[3] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, State Key Lab Luminescence & Applicat, Changchun 130033, Jilin, Peoples R China
[4] Univ Macau, Inst Appl Phys & Mat Engn, Joint Key Lab, Minist Educ, Taipa, Macao, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon dots; Fluorescent microspheres; Staphylococcal protein A; Staphylococcus aureus; Escherichia coli O157:H7;
D O I
10.1016/j.bios.2021.113057
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The rapid and early detection of foodborne pathogens in contaminated food is important for ensuring food safety and quality. In this study, a highly sensitive fluorescent immunosensor was developed to detect Escherichia coli O157:H7 in milk, by using microspheres labeled with carbon dots (CDs). The CDs-microspheres were prepared with Staphylococcus aureus cells as the carrier to incorporate CDs particles. Characterization of the microsphere revealed strong intensity, good stability and high uniformity in fluorescence. With Staphylococcal Protein A (SPA) on the surface of S. aureus cells, the microsphere could be easily coupled with various antibodies (e.g., immunoglobulin G). In combination with the immunomagnetic beads technique, a CDs-microsphere immunosensor was established for the specific detection of E. coli O157:H7 in milk. The limit of detection for E. coli O157: H7 is 2.4 x 10(2) colony-forming unit (CFU)/mL, comparable to that of real-time PCR methods. Milk samples spiked with E. coli O157:H7 at concentrations from 2.4 x 10(2) to 2.4 x 10(7) CFU/mL could be detected within 30 min. The coefficients of variation of the intra-assay tests were less than 10%, indicating a good repeatability. Moreover, the method was able to detect trace amounts of E. coli O157:H7 (<10 CFU) in real milk samples, with a 100% (10/10) accuracy after bacterial enrichment. This CDs-microsphere immunosensor shows considerable potential as a rapid and sensitive tool to detect pathogens in milk and other foods.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] Carbon dots and covalent organic frameworks based FRET immunosensor for sensitive detection of Escherichia coli O157:H7
    Wang, Sunli
    Liang, Nini
    Hu, Xuetao
    Li, Wenting
    Guo, Ziang
    Zhang, Xinai
    Huang, Xiaowei
    Li, Zhihua
    Zou, Xiaobo
    Shi, Jiyong
    FOOD CHEMISTRY, 2024, 447
  • [2] Rapid and sensitive detection of Escherichia coli O157:H7 using coaxial channel-based DNA extraction and microfluidic PCR
    Zhang, Huilin
    Huang, Fengchun
    Cai, Gaozhe
    Li, Yuntao
    Lin, Jianhan
    JOURNAL OF DAIRY SCIENCE, 2018, 101 (11) : 9736 - 9746
  • [3] Simultaneous detection of Escherichia coli O157:H7, Staphylococcus aureus and Salmonella by multiplex PCR in milk
    Wei, Caijiao
    Zhong, Junliang
    Hu, Ting
    Zhao, Xihong
    3 BIOTECH, 2018, 8
  • [4] Electrochemical Biosensing Interface Based on Carbon Dots-Fe3O4 Nanomaterial for the Determination of Escherichia coli O157:H7
    Lin, Xiaofeng
    Mei, Yanqiu
    He, Chen
    Luo, Yan
    Yang, Min
    Kuang, Ying
    Ma, Xiaoming
    Zhang, Huifang
    Huang, Qitong
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [5] Smartphone-based portable device for rapid and sensitive pH detection by fluorescent carbon dots
    Ehtesabi, Hamide
    Asadollahi, Amir
    Hallaji, Zahra
    Goudarzi, Mahsa
    Rezaei, Ali
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332
  • [6] The PCR-HCR dual signal amplification strategy for ultrasensitive detection of Escherichia coli O157:H7 in milk
    Liang, Taobo
    Wu, Xin
    Chen, Bolu
    Liu, Ju
    Aguilar, Zoraida P.
    Xu, Hengyi
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2020, 130
  • [7] A Rapid and Visual Method for Nucleic Acid Detection of Escherichia coli O157:H7 Based on CRISPR/Cas12a-PMNT
    Jiang, Wei
    He, Chuan
    Bai, Lan
    Chen, Yifan
    Jia, Junwei
    Pan, Aihu
    Lv, Beibei
    Tang, Xueming
    Wu, Xiao
    FOODS, 2023, 12 (02)
  • [8] A colorimetric lateral flow assay based on multiplex PCR for the rapid detection of viable Escherichia coli O157:H7 and Salmonella Typhimurium without enrichment
    Kim, Jin-Hee
    Oh, Se-Wook
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2021, 152
  • [9] Carbon dots-MnO2 based turn-on fluorescent probe for rapid and sensitive detection of hydrazine in water
    Hiremath, Sharanabasava D.
    Priyadarshi, Bhaskar
    Banerjee, Mainak
    Chatterjee, Amrita
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 389 (389)
  • [10] A Molecular Beacon-Based Duplex Real-Time Polymerase Chain Reaction Assay for Simultaneous Detection of Escherichia coli O157:H7 and Listeria monocytogenes in Milk and Milk Products
    Singh, Jitender
    Batish, Virender K.
    Grover, Sunita
    FOODBORNE PATHOGENS AND DISEASE, 2009, 6 (10) : 1195 - 1201