Pseudoarthrosis of the cervical spine - A comparison of radiographic diagnostic measures

被引:112
作者
Cannada, LK [1 ]
Scherping, SC [1 ]
Yoo, JU [1 ]
Jones, PK [1 ]
Emery, SE [1 ]
机构
[1] Case Western Reserve Univ, Dept Orthopaed, Univ Hosp Cleveland, Spine Inst, Cleveland, OH 44106 USA
关键词
cervical spine; Cobb angle; fusion; pseudarthrosis;
D O I
10.1097/00007632-200301010-00012
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A retrospective review was conducted. Objective. To compare the accuracy of two objective radiographic techniques in identifying nonunion after anterior cervical discectomy and fusion. Summary of Background Data. The accuracy of diagnostic methods for detecting pseudarthrosis has been poorly documented. Radiographic criteria mentioned in the literature include perceived motion or change in the Cobb angles between the involved segments on flexion-extension views. Methods. The participants in this study were 27 patients with 29 cervical fusions ranging from one to three levels. Patients were examine and radiographs obtained. The mean follow-up period was 39 months. Two measurements were obtained from lateral flexion-extension radiographs: Cobb angle and the distance between the tips of the spinous processes of the surgically managed levels. The measurements were obtained independently by three physicians in a blinded fashion. Results. The reliability among the observers, as measured by Cronbach's alpha, was 0.95 for the spinous process method and 0.74 for the Cobb angle method. A measurement of more than 2 mm between spinous processes was noted in patients with a known pseudarthrosis. The Pearson correlation between pseudarthrosis and use of the spinous process method was 0.77 (P<0.001). The Pearson correlation between pseudarthrosis and use of the Cobb angle method was 0.28 (P>0.10). The area under the receiver operating characteristic curve for the spinous process method was found to be 0.980, as compared with 0.662 for the Cobb angle method, for the measurement of pseudarthrosis. Conclusions. Measurement of the change in distance between spinous processes is more reproducible and accurate than the Cobb method for making the diagnosis of pseudarthrosis. The authors believe that the measurement of distances between spinous processes on lateral flexion-extension radiographs should be used as a method for evaluating radiographic fusion in patients with pseudarthrosis.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 13 条
[1]   ROBINSON ANTERIOR CERVICAL DISKECTOMY AND ARTHRODESIS FOR CERVICAL RADICULOPATHY - LONG-TERM FOLLOW-UP OF 100 AND 22 PATIENTS [J].
BOHLMAN, HH ;
EMERY, SE ;
GOODFELLOW, DB ;
JONES, PK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) :1298-1307
[2]  
Bohlman HH, 1995, AAOS INSTR COURS LEC, V44, P81
[3]   ROBINSON ANTERIOR CERVICAL FUSION - COMPARISON OF THE STANDARD AND MODIFIED TECHNIQUES [J].
EMERY, SE ;
BOLESTA, MJ ;
BANKS, MA ;
JONES, PK .
SPINE, 1994, 19 (06) :660-663
[4]   PSEUDARTHROSIS OF THE CERVICAL-SPINE AFTER ANTERIOR ARTHRODESIS - TREATMENT BY POSTERIOR NERVE-ROOT DECOMPRESSION, STABILIZATION, AND ARTHRODESIS [J].
FAREY, ID ;
MCAFEE, PC ;
DAVIS, RF ;
LONG, DM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (08) :1171-1177
[5]   The use of diagnostic imaging to assess spinal arthrodesis [J].
Hilibrand, AS ;
Dina, TS .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (04) :591-+
[6]   Anterior cervical discectomy with freeze-dried fibula allograft - Overview of 317 cases and literature review [J].
Martin, GJ ;
Haid, RW ;
MacMillan, M ;
Rodts, GE ;
Berkman, R .
SPINE, 1999, 24 (09) :852-858
[7]   THE OUTCOME OF PSEUDOARTHROSIS AFTER CERVICAL ANTERIOR FUSION [J].
NEWMAN, M .
SPINE, 1993, 18 (16) :2380-2382
[8]   Anterior cervical pseudarthrosis - Natural history and treatment [J].
Phillips, FM ;
Carlson, G ;
Emery, SE ;
Bohlman, HH .
SPINE, 1997, 22 (14) :1585-1589
[9]   RESULTS OF ANTERIOR INTERBODY FUSION OF CERVICAL SPINE - REVIEW OF 93 CONSECUTIVE CASES [J].
RILEY, LH ;
ROBINSON, RA ;
JOHNSON, KA ;
WALKER, AE .
JOURNAL OF NEUROSURGERY, 1969, 30 (02) :127-&
[10]  
RISSER JC, 1982, INT SURG, V67, P181