Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study

被引:13
作者
Joos-Kovacs, G. [1 ]
Vecsei, B. [1 ]
Kormendi, Sz. [1 ]
Gyarmathy, V. A. [2 ,3 ]
Borbely, J. [1 ]
Hermann, P. [1 ]
机构
[1] Semmelweis Univ, Dept Prosthodont, Szentkiralyi U 47, H-1088 Budapest, Hungary
[2] EpiConsult LLC, 8 Green,Ste A, Dover, DE 19901 USA
[3] Johns Hopkins Bloomberg Sch Publ Hlth, Baltimore, MD USA
关键词
Digital dentistry; Desktop scanner; Indirect CAD; CAM digitization; Extraoral scanner; Gypsum cast digitization; Accuracy; Trueness; Precision; IMPRESSION TECHNIQUES; INTRAORAL SCANNERS; MARGINAL FIT; ACCURACY; ZIRCONIA; PUTTY; EFFICIENCY; PRECISION; SYSTEMS;
D O I
10.1186/s12903-019-0976-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Desktop scanners are devices for digitization of conventional impressions or gypsum casts by indirect Computer-Aided Design/Computer-Assisted Manufacturing (CAD/CAM) in dentistry. The purpose of this in vitro study was: 1, to investigate whether virtual models produced by the extraoral scanner have the same trueness as sectioned casts; and 2, to assess if digitization with an extraoral scanner influences the surface information. Methods A polimethyl-methacrilic acid (PMMA) cast and a reference scanner (TwoCam 3D, SCAN technology A/S, Ringsted, Denmark; field of view 200 mm, resolution 0.1 mm +/- 0.025 mm) were used to create the reference data in standard tessellation format (STL). According to the extraoral CAD/CAM digitization steps, impressions, mastercasts, and sectioned casts were made, and STL files were generated with the reference scanner. The pivotal point of the study was to digitalize these sectioned casts with the extraoral scanner (Straumann CARES Scan CS2 Visual 8.0 software, InstitutStraumann AG, Basel, Switzerland) and STL files were exported. Virtual caliper measurements were performed. Absolute deviations were compared using multilevel mixed-effects linear regression. Relative distortions were calculated with mean absolute errors and reference values. Results Differences were observed in measurements of tooth sizes. All four prepared teeth were affected. No relationship was observed in relative deviations. Absolute differences between all the indirect digitization steps considering arch distances were: impressions, - 0.004 mm; mastercasts, 0.136 mm; sectioned casts, - 0.028 mm; and extraoral scanner, - 0.089 mm. Prepared dies on the virtual casts (extraoral scanner) were closer to each other than those on the sectioned gypsum casts. Relative deviation calculations revealed no relationship with the position of the dies in the arch. Conclusion The trueness of the virtual models generated by the extraoral scanner system used in this study was different from the dimensions of the sectioned casts. The digitization of gypsum casts changes both the dimensions of dies and the distances between the dies. The virtual casts had smaller distances than any distances measured at previous steps. Either bigger dies or longer distances did not result in greater distortions. We cannot, however, generalize our results to all scanners available on the market, because they might give different results.
引用
收藏
页数:14
相关论文
共 41 条
[1]  
Ahmad Manawar, 2014, Indian J Dent Res, V25, P197, DOI 10.4103/0970-9290.135921
[2]   Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques [J].
Almeida e Silva, Junio S. ;
Erdelt, Kurt ;
Edelhoff, Daniel ;
Araujo, Elito ;
Stimmelmayr, Michael ;
Cardoso Vieira, Luiz Clovis ;
Gueth, Jan-Frederik .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) :515-523
[3]  
[Anonymous], 2013, J PROSTHET DENT, V109, P52
[4]  
Aramouni P, 1993, Int J Prosthodont, V6, P533
[5]   Digital dentistry: an overview of recent developments for CAD/CAM generated restorations [J].
Beuer, F. ;
Schweiger, J. ;
Edelhoff, D. .
BRITISH DENTAL JOURNAL, 2008, 204 (09) :505-511
[6]  
Council on Dental Materials Instruments and Equipment, 1985, J AM DENT ASSOC, V111, P1003
[7]   Prognostic indicators for conventional complete denture therapy: A review of the literature [J].
Critchlow, Simon B. ;
Ellis, Janice S. .
JOURNAL OF DENTISTRY, 2010, 38 (01) :2-9
[8]   Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays [J].
Denissen, H ;
Dozic, A ;
van der Zel, J ;
van Waas, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (05) :506-513
[9]   Clinical efficacy of polyvinyl siloxane impression materials using the one-step two-viscosity impression technique [J].
Dogan, Sami ;
Schwedhelm, E. Ricardo ;
Heindl, Harald ;
Mancl, Lloyd ;
Raigrodski, Ariel J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (02) :217-222
[10]  
Dugal Ramandeep, 2013, J Int Oral Health, V5, P85