Simulation of Cherenkov photons emitted in photomultiplier windows induced by Compton diffusion using the Monte Carlo code GEANT4

被引:17
|
作者
Thiam, C. [1 ]
Bobin, C. [1 ]
Bouchard, J. [1 ]
机构
[1] CEA, LIST, LNE, LNHB, F-91191 Gif Sur Yvette, France
关键词
TDCR method; Liquid scintillation counting; GEANT4; simulation; Cherenkov effect; BIALKALI PHOTOCATHODES; CERENKOV RADIATION; COINCIDENCE SYSTEM;
D O I
10.1016/j.apradiso.2009.11.066
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The implementation of the TDCR method (Triple to Double Coincidence Ratio) is based on a liquid scintillation system which comprises three photomultipliers: at LNHB, this counter can also be used in the beta-channel of a 4 pi(beta)beta-gamma coincidence counting equipment It is generally considered that the gamma-sensitivity of the liquid scintillation detector comes from the interaction of the gamma-photons in the scintillation cocktail but when introducing solid gamma-ray emitting sources instead of the scintillation vial, light emitted by the surrounding of the counter is observed. The explanation proposed in this article is that this effect comes from the emission of Cherenkov photons induced by Compton diffusion in the photomultiplier windows In order to support this assertion, the creation and the propagation of Cherenkov photons inside the TDCR counter is simulated using the Monte Carlo code GEANT4. Stochastic calculations of double coincidences confirm the hypothesis of Cherenkov light produced in the photomultipher windows (C) 2009 Elsevier Ltd. All rights reserved
引用
收藏
页码:1515 / 1518
页数:4
相关论文
共 25 条
  • [21] Investigation the trend of different magnetic fields types on linac photon beam mode by Monte Carlo method using Geant4 toolkit
    Zanganeh, Vahid
    Khabaz, Rahim
    Aghili, Fatemeh
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [22] Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
    Gebremariam, Tsige Yhidego
    Geraily, Ghazale
    Jassim, Hussam Hameed
    Gholami, Somayeh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (02) : 141 - 147
  • [23] Calculation of water equivalent ratios for various materials at proton energies ranging 10-500 MeV using MCNP, FLUKA, and GEANT4 Monte Carlo codes
    Safigholi, Habib
    Song, William Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15):
  • [24] Correlated Production and Analog Transport of Fission Neutrons and Photons using Fission Models FREYA, FIFRELIN and the Monte Carlo Code TRIPOLI-4®
    Verbeke, Jerome M.
    Petit, Odile
    Litaize, Olivier
    Chebboubi, Abdelhazize
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2017), 2018, 170
  • [25] The effect of 111In radionuclide distance and auger electron energy on direct induction of DNA double-strand breaks: a Monte Carlo study using Geant4 toolkit
    Piroozfar, Behnaz
    Raisali, Gholamreza
    Alirezapour, Behrouz
    Mirzaii, Mohammad
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2018, 94 (04) : 385 - 393