Development of voltammetric sensor based on polyimide-MWCNT composite membrane for rapid and highly sensitive detection of paracetamol

被引:42
作者
Burc, Muammer [1 ]
Koytepe, Suleyman [1 ]
Duran, Serap Titretir [1 ]
Ayhan, Nurcan [1 ]
Aksoy, Busra [1 ]
Seckin, Turgay [1 ]
机构
[1] Inonu Univ, Fac Arts & Sci, Dept Chem, TR-44280 Malatya, Turkey
关键词
Voltammetric sensor; Polyimide-MWCNT composite membrane; Paracetamol; Polyimide; Modified electrode; ELECTROCHEMICAL SENSOR; FLOW-INJECTION; ACETAMINOPHEN; BIOSENSOR; ELECTRODE; FILM;
D O I
10.1016/j.measurement.2019.107103
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work, for low level detection of paracetamol (PA) a voltammetric sensor was obtained. Polyimidemultiwall carbon nanotube (PI-MWCNT) composite film was used for modification of platinum (Pt) electrode as selective membrane. Firstly, this PI-MWCNT film was synthesized with 2,5-diaminopyridine (DAP), 4,4'-oxydiphthalic anhydride (ODPA) and MWCNT as a reinforcement by thermal imidization technique. The morphology, micro and chemical structures of the obtained composite film were studied by Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM) and thermal analysis techniques. Then, the paracetamol sensor was prepared via the modification of Pt electrode with prepared PI-MWCNT composite film. Pt electrode was modified by coating with prepared PI-MWCNT composite film. Modified Pt electrode was used as PA sensor due to its selective membrane property in the presence of interfering substances for the electrochemical detection of PA. Electrochemical behaviour of paracetamol at the polyimide film modified Pt electrode was obtained by differential pulse voltammetry (DPV) and cyclic voltammetry (CV) method. It has shown that the modified electrode exhibits remarkable repeatability and precision in analytical paracetamol response as compared with other modified paracetamol electrodes. Comparing the responses of modified electrode with the unmodified Pt electrode, selectivity, sensitivity and stable responses significantly enhanced. A linear calibration plot having a correlation coefficient of 0.997 was obtained in the concentration range from 0.3 to 1.8 mM paracetamol. A linear calibration plot for low concentration area having a correlation coefficient of 0.999 was obtained in the concentration range from 0.002 to 0.05 mM paracetamol. Detection limit (LOD) and quantitative limit (LOQ) for paracetamol detection of PI-MWCNT modified electrode were calculated as 0.002 mM and 0.006 mM respectively. In addition, the presented method was applied for determination of PA in commercial tablets. The recovery efficiency of the PI modified electrode was obtained range of 96% and 102% for three different tablets. As a result; a simple, rapid, low cost, repeatable method showing good accuracy and precision (99.4%) has been developed for the selective and sensitive determination of paracetamol by prepared PI-MWCNT composite film modified electrode. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 37 条
[1]   A novel electrochemical biosensor based on polyimide- boron nitride composite membranes [J].
Aksoy, Busra ;
Pasahan, Aziz ;
Gungor, Oznur ;
Koytepe, Suleyman ;
Seckin, Turgay .
INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2017, 66 (04) :203-212
[2]   Preparation of Novel Sensors Based on Polyimide Membrane for Sensitive and Selective Determination of Dopamine [J].
Aksoy, Busra ;
Gungor, Oznur ;
Koytepe, Suleyman ;
Seckin, Turgay .
POLYMER-PLASTICS TECHNOLOGY AND ENGINEERING, 2016, 55 (02) :119-128
[3]  
[Anonymous], PENCINER J ELECTROAN
[4]   Determination of the rate constants and activation energy of acetaminophen hydrolysis by capillary electrophoresis [J].
Chen, G ;
Ye, JN ;
Bao, HM ;
Yang, PY .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) :843-850
[5]   Synthesis, characterization and properties of TAP-6FDA hyperbranched polyimides with different branching degrees [J].
Chen, Ying ;
Zhang, Qiuyu ;
Sun, Wanlu ;
Lei, Xingfeng ;
Yao, Pan .
POLYMER INTERNATIONAL, 2014, 63 (04) :788-795
[6]   Simultaneous Determination of Acetaminophen and Synthetic Color(s) by Derivative Spectroscopy in Syrup Formulations and Validation by HPLC: Exposure Risk of Colors to Children [J].
Das Rastogi, Shanya ;
Dixit, Sumita ;
Tripathi, Anurag ;
Das, Mukul .
AAPS PHARMSCITECH, 2015, 16 (03) :505-517
[7]   Simultaneous determination of N-acetylcysteine and acetaminophen by voltammetric method using N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide modified multiwall carbon nanotubes paste electrode [J].
Ensafi, Ali A. ;
Karimi-Maleh, Hassan ;
Mallakpour, S. ;
Hatami, M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 155 (02) :464-472
[8]   Preparation of the L-Asparaginase-Based Biosensor With Polyimide Membrane Electrode for Monitoring L-Asparagine Levels in Leukemia [J].
Erdogan, Ali ;
Koytepe, Suleyman ;
Ates, Burhan ;
Yilmaz, Ismet ;
Seckin, Turgay .
INTERNATIONAL JOURNAL OF POLYMERIC MATERIALS AND POLYMERIC BIOMATERIALS, 2014, 63 (17) :909-917
[9]   Electrochemical evaluation and voltammetric determination of laxative drug bisacodyl on boron-doped diamond electrode [J].
Falone, Max Fabricio ;
Rossi Salamanca-Neto, Carlos Alberto ;
Moraes, Jaqueline Tobias ;
Sartori, Elen Romao .
MEASUREMENT, 2019, 137 :464-469
[10]   Carbon film resistor electrode for amperometric determination of acetaminophen in pharmaceutical formulations [J].
Felix, Fabiana S. ;
Brett, Christopher M. A. ;
Angnes, Lucio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1622-1627