The fusion-FEM: experiments in long pulse set-up

被引:0
|
作者
Bongers, WA [1 ]
Bratman, VL [1 ]
Denisov, GG [1 ]
van der Geer, CAJ [1 ]
Manintveld, P [1 ]
Militsyn, B [1 ]
Oomens, AAM [1 ]
Poelman, AJ [1 ]
Pluygers, J [1 ]
Riet, M [1 ]
Savilov, AV [1 ]
Shmelyov, MY [1 ]
Smeets, PHM [1 ]
Verhoeven, AGA [1 ]
Urbanus, WH [1 ]
机构
[1] EURATOM Assoc, FOM, Inst Plasmafys Rijnhuizen, NL-3430 BE Nieuwegein, Netherlands
关键词
D O I
10.1109/ICMMT.2000.895727
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Free-Electron Maser (FEM) is a high power, wide band, tunable mm-wave source in the range of 130-260 GHz for fusion applications Ii]. Without electron beam recovery, the Fusion-FEM has generated over 700 kW at 200 GHz in the microsecond scale. Single-mode operation has been demonstrated at various frequencies. Presently, the Fusion FEM has been completed for long-pulse operation; the energy recovery system, a decelerator and a depressed collector, have been installed [2]. Ln this paper we present results on measurements of the complete mm-wave beam line for long-pulse operation.
引用
收藏
页码:489 / 490
页数:2
相关论文
共 50 条
  • [1] The fusion-FEM: experiments in long pulse set-up
    Bongers, WA
    Bratman, VL
    Denisov, GG
    van der Geer, CAJ
    Manintveld, P
    Militsyn, B
    Oomens, AAM
    Poelman, AJ
    Pluygers, J
    Riet, M
    Savilov, AV
    Shmelyov, MY
    Smeets, PHM
    Verhoeven, AGA
    Urbanus, WH
    2000 25TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES CONFERENCE DIGEST, 2000, : 165 - 166
  • [2] First lasing of the Dutch fusion-FEM in the long-pulse configuration
    Militsyn, BL
    Bongers, WA
    Bratman, VL
    Caplan, M
    Denisov, GG
    van der Geer, CAJ
    Manintveld, P
    Oomens, AAM
    Plomp, J
    Pluygers, J
    Poelman, AJ
    Riet, M
    Savilov, AV
    Smeets, PHM
    Tito, CJ
    Turk, GHB
    Varfolomeev, AA
    Urbanus, WH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (1-2): : 259 - 262
  • [3] A TOROIDAL SET-UP FOR PLASMA EXPERIMENTS
    BERGLUND, S
    SVENNERSTEDT, S
    ARKIV FOR FYSIK, 1962, 22 (05): : 394 - 394
  • [4] The Scent of Filth: Experiments, Waste, and the Set-Up
    Hoffmann, Christoph
    GOING AMISS IN EXPERIMENTAL RESEARCH, 2009, 267 : 239 - 251
  • [5] Development of HSPECM set-up and its experiments
    Di, SC
    Wu, HB
    Zhao, WS
    Chi, GX
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2005, 15 : 274 - 278
  • [6] A measurement set-up for photoconductivity decay experiments
    Pisarkiewicz, T
    Kuta, S
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (06) : 1007 - 1009
  • [7] The Scent of Filth: Experiments, Waste, and the Set-Up
    Hoffmann, Christoph
    GOING AMISS IN EXPERIMENTAL RESEARCH, 2009, 267 : 239 - 251
  • [8] Demonstration of low-loss electron beam transport and mm-wave experiments of the fusion-FEM
    Urbanus, WH
    Bongers, WA
    van Dijk, G
    van der Geer, CAJ
    de Kruif, R
    Manintveld, P
    Pluygers, J
    Poelman, AJ
    Schuller, FC
    Smeets, PHM
    Sterk, AB
    Verhoeven, AGA
    Valentini, M
    van der Wiel, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 407 (1-3): : 327 - 331
  • [9] Temporal dynamics of Fusion-FEM oscillations: comparison of experiment and simulations
    Savilov, AV
    Bratman, VL
    Denisov, GG
    Bongers, WA
    van der Geer, CAJ
    Manintveld, P
    Verhoeven, AGA
    Urbanus, WH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 429 (1-3): : 46 - 51
  • [10] SET-UP FOR PULSE-RADIOLYSIS OF AGGRESSIVE SUBSTANCES
    KOZLOWSKAMILNER, E
    BROSZKIEWICZ, R
    STANIKOWSKI, J
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1975, 22 (04): : 269 - 273