Comparison of Two Minimally Invasive Osteosynthesis Techniques for Radial Head Fractures in Paediatric Patients

被引:0
|
作者
Marek, O. [1 ]
Turek, J. [1 ]
Seehofnerova, A. [2 ]
Planka, L. [1 ]
Stichhauer, R. [3 ]
机构
[1] Masarykovy Univ, Lekarska Fak, Fak Nemocnice Brno, Klin Detske Chirurg Ortopedie Traumatol, Brno, Czech Republic
[2] Masarykovy Univ, Lekarska Fak, Fak Nemocnice Brno, Klin Detske Radiol, Brno, Czech Republic
[3] Univ Karlovy, Lekarska Fak, Fak Nemocnice Hradec Kralove, Oddeleni Detske Chirurg & Traumatol, Hradec Kralove, Czech Republic
关键词
minimally invasive osteosynthesis; radial head; fracture; child; NECK FRACTURES; CHILDREN; REDUCTION; MANAGEMENT; FIXATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PURPOSE OF THE STUDY Radial head fractures in paediatric patients account for 5-19% of all elbow injuries and approximately 1% of all fractures in children. Non-displaced fractures are treated with plaster cast fixation. If the fracture is displaced, we proceed to closed reduction, or to osteosynthesis in case of unstable fragments. If closed reduction fails, we opt for open reduction and osteosynthesis. The prospective randomised clinical study aims to compare the two methods of minimally invasive osteosynthesis using the pre-bent Kirschner wire or Prevot nail and to identify differences between them. MATERIAL AND METHODS The prospective randomised clinical study was conducted in 2015-2019. The final cohort included 32 patients who met the inclusion criteria. The patients in whom other osteosynthesis implants had been used or in whom open reduction had to be performed were excluded from the study. Also excluded were the patients with serious concomitant injuries of elbow. For patients included in the cohort, demographic data, precise evaluation of the displacement and location of the fracture as well as the duration of plaster cast fixation and osteosynthesis implants used were recorded. In the clinical part, the methods were compared based on the achievement of full range of motion in dependence on the degree of original displacement, use of osteosynthesis implant, and occurrence of early and delayed complications. Clinical and radiological outcomes were compared. In both types of minimally invasive osteosynthesis, Metaizeau surgical technique was used. RESULTS Based on the clinical trial criteria, 26 (81%) excellent, 4 (13%) good and 2 (6%) acceptable outcomes were achieved. In 3 cases the loss of rotation was up to 20 degrees, in 1 case the loss of flexion was up to 10 degrees. In one patient the loss of flexion was 15 degrees and rotation up to 30 degrees. In another patient the loss of rotation was up to 40 degrees. The radiological assessment showed 14 (44%) excellent outcomes, 15 good (47%) and 3 (9%) acceptable outcomes. The statistical analysis of both the groups of the cohort using non-parametric tests revealed no statistically significant differences in individual demographic parameters. The comparisons of both types of osteosynthesis in dependence on the degree of displacement by non-parametric Fisher's exact test showed no statistically significant difference in the radiologic or clinical results. The only statistically significant difference was observed in the duration of metal implant placement. DISCUSSION Comparable studies report excellent or good clinical outcomes in 80-95% of cases (1,13,16). In our cohort, excellent or good clinical outcomes were achieved in 30 patients (94%). In two patients, in whom Prevot nail was used, the outcomes were acceptable. Nonetheless, this fact did not result in any statistical significance when comparing the two methods separately or in comparisons based on the degree of displacement. CONCLUSIONS The comparison of the two methods of minimally invasive osteosynthesis revealed no statistically significant difference, namely not even when both the methods were compared based on the degree of displacement. When Kirschner wire is used, the possibility to remove the metal implant in the outpatient setting is considered to be an advantage. The drawback consists in potential penetration of the sharp Kirschner wire in the radiocapitellar joint, which we did not encounter when the second technique of osteosynthesis was used. The advantage of Prevot nail includes a lower risk of pin-tract infection.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [31] Minimally invasive plate osteosynthesis (MIPO) in diaphyseal humerus and proximal humerus fractures
    Aksu, Neslihan
    Karaca, Sinan
    Kara, Ayhan Nedim
    Isiklar, Zekeriya Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (03) : 154 - 160
  • [32] Minimally Invasive Plate Osteosynthesis in Open Pediatric Tibial Fractures
    Ozkul, Emin
    Gem, Mehmet
    Arslan, Huseyin
    Alemdar, Celil
    Azboy, Ibrahim
    Arslan, Seher G.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (04) : 416 - 422
  • [33] Treatment of distal tibial fractures with minimally invasive plate osteosynthesis
    Ari, Bunyamin
    Bicici, Vedat
    Akkurt, Mehmet Orcun
    Ergen, Emre
    Aslanturk, Okan
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 : 239 - 242
  • [34] Minimally invasive plate osteosynthesis versus conventional open insertion techniques for osteosynthesis
    Toogood, Paul
    Huang, Adrian
    Siebuhr, Karl
    Miclau, Theodore
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 : S19 - S23
  • [35] Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius
    Imatani, J
    Noda, T
    Morito, Y
    Sato, T
    Hashizume, H
    Inoue, H
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2005, 30B (02) : 220 - 225
  • [36] Minimally Invasive Anterior Plate Osteosynthesis in Humeral Shaft Fractures
    Schwarz, Nikolaus
    Windisch, Manfred
    Mayr, Birgit
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2009, 35 (03) : 271 - 276
  • [37] Minimally Invasive Osteosynthesis of Intraarticular Calcaneus Fracture Augmented by Femoral Head Allograft: A Retrospective Study
    Moussa, Mohamad K.
    Vuilletet, Emma
    Alayane, Ali
    Boushnak, Mohammad O.
    Fleurette, Justine
    Nicolas, Nicolas
    Thiongo, Maurice
    Missaoui, Zied
    Kassab, Georges
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [38] A retrospective comparison of minimally invasive percutaneous plate osteosynthesis (MIPPO) and minimally invasive percutaneous titanium elastic nail osteosynthesis (MIPTENO) for midshaft clavicle fracture
    Chen, Long
    Chen, Hui
    Nisar, Majid
    Chen, Hua
    Pan, Jun
    Peng, Lei
    Chen, Qingyu
    Zhou, Dongsheng
    Hong, Jianjun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 870 - 876
  • [39] Case-Match Controlled Comparison of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing for the Stabilization of Humeral Shaft Fractures
    Davies, Gareth
    Yeo, Gerald
    Meta, Mahendrakumar
    Miller, David
    Hohmann, Erik
    Tetsworth, Kevin
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (11) : 612 - 617
  • [40] Soft tissue protective and minimally invasive osteosynthesis for metacarpal fractures II-V
    Dumont, C.
    Burchhardt, H.
    Tezval, M.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2012, 24 (4-5): : 312 - 323