Comparison of Two Minimally Invasive Osteosynthesis Techniques for Radial Head Fractures in Paediatric Patients

被引:0
|
作者
Marek, O. [1 ]
Turek, J. [1 ]
Seehofnerova, A. [2 ]
Planka, L. [1 ]
Stichhauer, R. [3 ]
机构
[1] Masarykovy Univ, Lekarska Fak, Fak Nemocnice Brno, Klin Detske Chirurg Ortopedie Traumatol, Brno, Czech Republic
[2] Masarykovy Univ, Lekarska Fak, Fak Nemocnice Brno, Klin Detske Radiol, Brno, Czech Republic
[3] Univ Karlovy, Lekarska Fak, Fak Nemocnice Hradec Kralove, Oddeleni Detske Chirurg & Traumatol, Hradec Kralove, Czech Republic
关键词
minimally invasive osteosynthesis; radial head; fracture; child; NECK FRACTURES; CHILDREN; REDUCTION; MANAGEMENT; FIXATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PURPOSE OF THE STUDY Radial head fractures in paediatric patients account for 5-19% of all elbow injuries and approximately 1% of all fractures in children. Non-displaced fractures are treated with plaster cast fixation. If the fracture is displaced, we proceed to closed reduction, or to osteosynthesis in case of unstable fragments. If closed reduction fails, we opt for open reduction and osteosynthesis. The prospective randomised clinical study aims to compare the two methods of minimally invasive osteosynthesis using the pre-bent Kirschner wire or Prevot nail and to identify differences between them. MATERIAL AND METHODS The prospective randomised clinical study was conducted in 2015-2019. The final cohort included 32 patients who met the inclusion criteria. The patients in whom other osteosynthesis implants had been used or in whom open reduction had to be performed were excluded from the study. Also excluded were the patients with serious concomitant injuries of elbow. For patients included in the cohort, demographic data, precise evaluation of the displacement and location of the fracture as well as the duration of plaster cast fixation and osteosynthesis implants used were recorded. In the clinical part, the methods were compared based on the achievement of full range of motion in dependence on the degree of original displacement, use of osteosynthesis implant, and occurrence of early and delayed complications. Clinical and radiological outcomes were compared. In both types of minimally invasive osteosynthesis, Metaizeau surgical technique was used. RESULTS Based on the clinical trial criteria, 26 (81%) excellent, 4 (13%) good and 2 (6%) acceptable outcomes were achieved. In 3 cases the loss of rotation was up to 20 degrees, in 1 case the loss of flexion was up to 10 degrees. In one patient the loss of flexion was 15 degrees and rotation up to 30 degrees. In another patient the loss of rotation was up to 40 degrees. The radiological assessment showed 14 (44%) excellent outcomes, 15 good (47%) and 3 (9%) acceptable outcomes. The statistical analysis of both the groups of the cohort using non-parametric tests revealed no statistically significant differences in individual demographic parameters. The comparisons of both types of osteosynthesis in dependence on the degree of displacement by non-parametric Fisher's exact test showed no statistically significant difference in the radiologic or clinical results. The only statistically significant difference was observed in the duration of metal implant placement. DISCUSSION Comparable studies report excellent or good clinical outcomes in 80-95% of cases (1,13,16). In our cohort, excellent or good clinical outcomes were achieved in 30 patients (94%). In two patients, in whom Prevot nail was used, the outcomes were acceptable. Nonetheless, this fact did not result in any statistical significance when comparing the two methods separately or in comparisons based on the degree of displacement. CONCLUSIONS The comparison of the two methods of minimally invasive osteosynthesis revealed no statistically significant difference, namely not even when both the methods were compared based on the degree of displacement. When Kirschner wire is used, the possibility to remove the metal implant in the outpatient setting is considered to be an advantage. The drawback consists in potential penetration of the sharp Kirschner wire in the radiocapitellar joint, which we did not encounter when the second technique of osteosynthesis was used. The advantage of Prevot nail includes a lower risk of pin-tract infection.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 50 条
  • [21] Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?
    Concha, Juan M.
    Sandoval, Alejandro
    Streubel, Philipp N.
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1297 - 1305
  • [22] Minimally invasive plate osteosynthesis of distal fractures of the tibia
    Helfet, DL
    Shonnard, PY
    Levine, D
    Borrelli, J
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 : SA42 - SA48
  • [23] Posterior minimally invasive plate osteosynthesis (MIPO) of distal third humeral shaft fractures with segmental isolation of the radial nerve
    Gallucci, G. L.
    Boretto, J. G.
    Alfie, V. A.
    Donndorff, A.
    De Carli, P.
    CHIRURGIE DE LA MAIN, 2015, 34 (05) : 221 - 226
  • [24] Comparison between minimally invasive, percutaneous osteosynthesis and locking plate osteosynthesis in 3-and 4-part proximal humerus fractures
    Ortmaier, Reinhold
    Filzmaier, Verena
    Hitzl, Wolfgang
    Bogner, Robert
    Neubauer, Thomas
    Resch, Herbert
    Auffarth, Alexander
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [25] Comparison of a minimally invasive osteosynthesis technique with conventional open surgery for transverse patellar fractures
    Yao, Li-Wei
    Mao, Hai-Jiao
    Dong, Wen-Wei
    Wu, Ze-Ting
    Liu, Qing
    CHINESE JOURNAL OF TRAUMATOLOGY, 2023, 26 (05) : 261 - 266
  • [26] Minimally invasive plate osteosynthesis of distal tibial fractures: a comparison of medial and lateral plating
    Shon, Oog-jin
    Park, Chul-hyun
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2012, 17 (05) : 562 - 566
  • [27] Minimally invasive plate osteosynthesis of acetabular anterior column fractures using the two-incision minimally invasive approach and a preshaped three dimension plate
    Zhuang, Yan
    Cao, Shenglu
    Lin, Yanbin
    Li, Renbin
    Wang, Gang
    Wang, Yiran
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (10) : 2157 - 2162
  • [28] Minimally Invasive Plate Osteosynthesis Fracture Reduction Techniques in Small Animals
    Peirone, Bruno
    Rovesti, Gian Luca
    Baroncelli, Alessandro Boero
    Piras, Lisa
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2012, 42 (05) : 873 - +
  • [29] Comparison between minimally invasive plate osteosynthesis and open plating for proximal humeral fractures: a meta-analysis
    Zang, Jia-cheng
    Du, Jing-jing
    Li, Chen
    Wang, Jing-bo
    Ma, Xin-long
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2018, 7 (10) : 1001 - 1008
  • [30] Minimally Invasive Anterior Plate Osteosynthesis in Humeral Shaft Fractures
    Nikolaus Schwarz
    Manfred Windisch
    Birgit Mayr
    European Journal of Trauma and Emergency Surgery, 2009, 35 : 271 - 276