UNDERESTIMATION OF PUPIL SIZE BY CRITICAL CARE AND NEUROSURGICAL NURSES

被引:42
作者
Kerr, Robert G. [1 ]
Bacon, Andrea M. [2 ]
Baker, Laura L. [2 ]
Gehrke, Janelle S. [2 ]
Hahn, K. Danielle [2 ]
Lillegraven, Cheryl L. [2 ]
Renner, Catherine Hackett [2 ]
Spilman, Sarah K. [2 ]
机构
[1] Hofstra North Shore Long Isl Jewish Sch Med, Huntingdon, NY USA
[2] UnityPoint Hlth, Des Moines, IA USA
关键词
DIAMETER; INJURY; SCALE;
D O I
10.4037/ajcc2016554
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Early detection of pupillary changes in patients with head injuries can alert the care team to increasing intracranial pressure. Previous research has shown inconsistencies in pupil measurement that are most likely due to the subjective nature of measuring pupils without the assistance of technology. Objectives To evaluate nurses' abilities to assess pupil diameter accurately and detect unequal pupils. Methods In a 3-part study, the accuracy of critical care and neurosurgical nurses' assessments of pupils was determined. The study included assessment of drawings of eyes with an iris and pupil, examination of photographs of human eyes, and bedside examination of patients with a head injury. Results Subjective assessments of pupil diameter and symmetry were not accurate. Across all phases of the study, pupil diameters were underestimated and the rate of error increased as pupil size increased. Nurses also failed to detect anisocoria and misidentified pupil reactivity. In addition, nearly all nurses relied on subjective estimation, even when tools were available. Conclusions Critical care and neurosurgical nurses underestimated pupil size, were unable to detect anisocoria, and incorrectly assessed pupil reactivity. Standardized use of pupil assessment tools such as a pupillometer is necessary to increase accuracy and consistency in pupil measurement and to potentially contribute to earlier detection of subtle changes in pupils. If pupillary changes are identified early, diagnostic and treatment intervention can be delivered in a more timely and effective manner.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 18 条
[1]  
Adoni Andea, 2007, J Trauma Nurs, V14, P191
[2]  
American Association of Neuroscience Nurses ( AANN), 2009, NEUR ASS OLD AD GUID
[3]   The Effect of Gender and Iris Color on the Dark-Adapted Pupil Diameter [J].
Bradley, Jay C. ;
Bentley, Karl C. ;
Mughal, Aleem I. ;
Bodhireddy, Hari ;
Young, Rockefeller S. L. ;
Brown, Sandra M. .
JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2010, 26 (04) :335-340
[4]  
Chen Jeff W, 2011, Surg Neurol Int, V2, P82, DOI 10.4103/2152-7806.82248
[5]   Variability in pupil size estimation [J].
Clark, A ;
Clarke, TNS ;
Gregson, B ;
Hooker, PNA ;
Chambers, IR .
EMERGENCY MEDICINE JOURNAL, 2006, 23 (06) :440-441
[6]   Fixed and dilated pupils after trauma, stroke, and previous intracranial surgery: management and outcome [J].
Clusmann, H ;
Schaller, C ;
Schramm, J .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2001, 71 (02) :175-181
[7]  
Hansen M, 1994, J NEUROL, V241, P495
[8]   Pupil evaluation in addition to Glasgow Coma Scale components in prediction of traumatic brain injury and mortality [J].
Hoffmann, M. ;
Lefering, R. ;
Rueger, J. M. ;
Kolb, J. P. ;
Izbicki, J. R. ;
Ruecker, A. H. ;
Rupprecht, M. ;
Lehmann, W. .
BRITISH JOURNAL OF SURGERY, 2012, 99 :122-130
[9]  
Hults Kathryn N, 2006, J Neurosci Nurs, V38, P447
[10]   Pupillary diameter assessment:: Need for a graded scale [J].
Litvan, I ;
Saposnik, G ;
Mauriño, J ;
Gonzalez, L ;
Saizar, R ;
Sica, REP ;
Bartko, JJ .