Comparison of transition temperature range and phase transformation behavior of nickel-titanium wires

被引:15
作者
Lee, Yu-Hyun [2 ]
Lim, Bum-Soon [2 ]
Lee, Yong-Keun [2 ]
Kim, Cheol-We [2 ]
Baek, Seung-Hak [1 ]
机构
[1] Seoul Natl Univ, Dept Orthodont, Sch Dent, Dent Res Inst, Seoul 110768, South Korea
[2] Seoul Natl Univ, Dept Dent Biomat Sci, Sch Dent, Dent Res Inst, Seoul 110768, South Korea
关键词
Transition temperature range; Phase transformation; Ni-Ti wires; DIFFERENTIAL SCANNING CALORIMETRY; X-RAY-DIFFRACTION; NI-TI WIRES; ORTHODONTIC WIRES; MECHANICAL-PROPERTIES; BENDING PROPERTIES; ARCH WIRES; ALLOY WIRE; ARCHWIRES; MARTENSITE;
D O I
10.4041/kjod.2010.40.1.40
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this research was to evaluate the mechanical properties (MP) and degree of the phase transformation (PT) of martensitic (M-NiTi), austenitic (A-NiTi) and thermodynamic nickel-titanium wire (T-NiTi). Methods: The samples consisted of 0.016 x 0.022 inch M-NiTi (Nitinol Classic, NC), A-NiTi (Optimalloy, OPTI) and T-NiTi (Neo-Sentalloy, NEO). Differential scanning calorimetry (DSC), three-point bending test, X-ray diffraction (XRD), and microstructure examination were used. Statistical evaluation was undertaken using ANOVA test. Results: In DSC analysis, OPTI and NEO showed two peaks in the heating curves and one peak in the cooling curves. However, NC revealed one single broad and weak peak in the heating and cooling curves. Austenite finishing (A(f)) temperatures were 19.7 degrees C for OPTI, 24.6 degrees C for NEO and 52.4 degrees C for NC. In the three-point bending test, residual deflection was observed for NC, OPTI and NEO. The load ranges of NC and OPTI were broader and higher than NEO. XRD and microstructure analyses showed that OPTI and NEO had a mixture of martensite and austenite at temperatures below Martensite finishing (M-f). NEO and OPTI showed improved MP and PT behavior than NC. Conclusions: The mechanical and thermal behaviors of NiTi wire cannot be completely explained by the expected degree of PT because of complicated martensite variants and independent PT induced by heat and stress. (Korean J Orthod 2010;40(1):40-49)
引用
收藏
页码:40 / 49
页数:10
相关论文
共 34 条
[1]  
Airoldi G, 1996, BIO-MED MATER ENG, V6, P299
[2]   Oral environment temperature changes induced by cold/hot liquid intake [J].
Airoldi, G ;
Riva, G ;
Vanelli, M ;
Filippi, V ;
Garattini, G .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1997, 112 (01) :58-63
[3]   An evaluation of the transition temperature range of super-elastic orthodontic NiTi springs using differential scanning calorimetry [J].
Barwart, O ;
Rollinger, JM ;
Burger, A .
EUROPEAN JOURNAL OF ORTHODONTICS, 1999, 21 (05) :497-502
[4]  
BISHARA SE, 1995, ANGLE ORTHOD, V65, P117
[5]   Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires [J].
Bradley, TG ;
Brantley, WA ;
Culbertson, BM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (06) :589-597
[6]   Temperature-modulated DSC provides new insight about transformations nickel-titanium wire [J].
Brantley, WA ;
Iijima, M ;
Grentzer, TH .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2003, 124 (04) :387-394
[7]   Microstructural studies of 35 °C Copper Ni-Ti orthodontic wire and TEM confirmation of low-temperature martensite transformation [J].
Brantley, William A. ;
Guo, Wenhua ;
Clark, William A. T. ;
Iijima, Masahiro .
DENTAL MATERIALS, 2008, 24 (02) :204-210
[8]   CHINESE NITI WIRE - A NEW ORTHODONTIC ALLOY [J].
BURSTONE, CJ ;
BAI, Q ;
MORTON, JY .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1985, 87 (06) :445-452
[9]  
Dalstra Michel, 2004, Orthod Craniofac Res, V7, P21, DOI 10.1046/j.1601-6335.2003.00275.x
[10]   Torsional properties of Ni-Ti and copper Ni-Ti wires: the effect of temperature on physical properties [J].
Filleul, MP ;
Jordan, L .
EUROPEAN JOURNAL OF ORTHODONTICS, 1997, 19 (06) :637-646