Investigation of commercial sorbents for the analysis of opioid peptides in human plasma by on-line SPE-CE

被引:25
作者
Benavente, Fernando [1 ]
Medina-Casanellas, Silvia [1 ]
Barbosa, Jose [1 ]
Sanz-Nebot, Victoria [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
MS; Neuropeptides; On-line; Preconcentration; Plasma; UV; SOLID-PHASE EXTRACTION; ELECTROPHORESIS-MASS SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; CEREBROSPINAL-FLUID; DEPROTEINIZATION METHODS; BIOLOGICAL MATRICES; SAMPLE PREPARATION; MS; SEPARATION; ULTRAFILTRATION;
D O I
10.1002/jssc.200900669
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we investigated the performance of several commercial sorbents (Sep-pack (R) C18, (t)C18, C8 and (t)C2, Oasis (R) HLB, Isolute (R) ENV+, Strata (TM)-X and Oasis (R) MCX) for the determination of opioid peptides by solid-phase extraction coupled on-line to capillary electrophoresis (SPE-CE). First, standard solutions were analyzed in order to achieve the lowest LOD and the best electrophoretic separations using UV detection. The best results were obtained using C18, C8 and (t)C2 sorbents, which were examined for the analysis of spiked human plasma samples. A double-step sample clean-up pretreatment, which consisted of precipitation with acetonitrile and filtration, was needed to prevent saturation of the on-line SPE microcartridge. The filtration step was critical to obtain optimum analyte recovery and to clean up the sample matrix. A range of centrifugal filters and filtration conditions were tested and the recoveries of the sample pretreatment were evaluated by CE-ESI-MS. The LODs attained through SPE-CE-UV were approximately tenfold better with C18 than with C8 and (t)C2. The 0.1 mu g/mL LODs achieved by C18-SPE-CE-UV were further improved until we could detect 1 ng/mL concentrations of opioid peptides in plasma samples by C18-SPE-CE-ESI-MS, due to the outstanding selectivity of the MS detection.
引用
收藏
页码:1294 / 1304
页数:11
相关论文
共 38 条
[1]  
Ban E, 2001, ELECTROPHORESIS, V22, P2173, DOI 10.1002/1522-2683(20017)22:11<2173::AID-ELPS2173>3.0.CO
[2]  
2-8
[3]   Cerebrospinal fluid levels of opioid peptides in fibromyalgia and chronic low back pain [J].
Baraniuk, JN ;
Whalen, G ;
Cunningham, J ;
Clauw, DJ .
BMC MUSCULOSKELETAL DISORDERS, 2004, 5 (1)
[4]   Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry [J].
Benavente, Fernando ;
Cristina Vescina, M. ;
Hernandez, Elena ;
Sanz-Nebot, Victoria ;
Barbosa, Jose ;
Guzman, Norberto A. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) :205-212
[5]   Role of electrophoretic mobility of protein on its retention by an ultrafiltration membrane - Comparison to chromatography mechanisms [J].
Chaufer, B ;
Rabiller-Baudry, M .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (01) :3-16
[6]   A global approach of ultrafiltration of complex biological solutions [J].
Darnon, E ;
Lafitte, L ;
Belleville, MP ;
Rios, GM .
SEPARATION AND PURIFICATION TECHNOLOGY, 2002, 26 (2-3) :283-293
[7]   The comparison of plasma deproteinization methods for the detection of low-molecular-weight metabolites by 1H nuclear magnetic resonance spectroscopy [J].
Daykin, CA ;
Foxall, PJD ;
Connor, SC ;
Lindon, JC ;
Nicholson, JK .
ANALYTICAL BIOCHEMISTRY, 2002, 304 (02) :220-230
[8]   Capillary electrophoresis of proteins 2005-2007 [J].
Dolnik, Vladislav .
ELECTROPHORESIS, 2008, 29 (01) :143-156
[9]   Development and evaluation of a chromatographic procedure for partial purification of substance P with quantitation by an enzyme immunoassay [J].
Fehder, WP ;
Ho, WZ ;
Campbell, DE ;
Tourtellotte, WW ;
Michaels, L ;
Cutilli, JR ;
Uvaydova, M ;
Douglas, SD .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1998, 5 (03) :303-307
[10]   A possible role for saliva as a diagnostic fluid in patients with chronic pain [J].
Fischer, HP ;
Eich, W ;
Russell, IJ .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1998, 27 (06) :348-359