Development of a quantitative vancomycin immunoassay for the Abbott AxSYM analyzer

被引:17
|
作者
Adamczyk, M
Brate, EM
Chiappetta, EG
Ginsburg, S
Hoffman, E
Klein, C
Perkowitz, MM
Rege, SD
Chou, PP
Costantino, AG
机构
[1] Abbott Labs, Abbott Diagnost Div, Abbott Pk, IL 60064 USA
[2] Amer Med Labs, Chantilly, VA USA
关键词
vancomycin; immunoassay; fluorescence; polarization; AxSYM analyzer;
D O I
10.1097/00007691-199804000-00010
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A novel fluorescence polarization immunoassay for vancomycin on Abbott AxSYM analyzer is described. The immunoassay allows for the accurate quantification of vancomycin in the presence of the crystalline degradation product (CDP). It displays dilution linearity from 1.0 mu g/ml to 100.0 mu g/ml, coefficients of variation ranging from 2.94% to 4.26%, recovery from 98% to 105%, and a sensitivity of <2.0 mu g/ml. The assay demonstrates no cross-reactivity to crystalline degradation product, and to commonly-prescribed and over-the-counter drugs, as well as a minimum interference from endogenous substances.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [41] An automated assay for Cardiac Troponin-I on the Abbott AxSYM(R) analyzer.
    Laird, DM
    Biegalski, T
    Forsythe, C
    Gall, G
    Hansen, H
    Keller, A
    Wilson, DH
    CLINICAL CHEMISTRY, 1997, 43 : 250 - 250
  • [42] Comparison between Bayer Immuno 1™ and Abbott AxSym™ automated immunoassay of ferritin.
    Gosney, K
    Hunter, CA
    Schiller, HS
    CLINICAL CHEMISTRY, 1998, 44 : A151 - A151
  • [43] Comparison of the ADVIA Centaur® and Abbott AxSYM immunoassay systems for a routine diagnostic virology laboratory
    Taylor, P
    Pickard, G
    Gammie, A
    Atkins, M
    JOURNAL OF CLINICAL VIROLOGY, 2004, 30 : S11 - S15
  • [44] Massive venlafaxine overdose resulted in a false positive Abbott AxSYM® urine immunoassay for phencyclidine
    Bond, GR
    Steele, PE
    Uges, DRA
    JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 2003, 41 (07): : 999 - 1002
  • [45] Active B12: A rapid, automated assay for holotranscobalamin on the Abbott AxSYM analyzer
    Brady, Jeff
    Wilson, Lesley
    McGregor, Lynda
    Valente, Edward
    Orning, Lars
    CLINICAL CHEMISTRY, 2008, 54 (03) : 567 - 573
  • [46] Evaluation of the Abbott AxSYM Total Beta-HCG microparticle enzyme immunoassay.
    Parrish, D
    Girton, S
    Calascibetta, F
    Vecchio, C
    CLINICAL CHEMISTRY, 1996, 42 (06) : 100 - 100
  • [47] Performance evaluation of an immunoassay for the measurement of estradiol on the Abbott Architect® analyzer
    Williams, G
    Hayes, F
    Frost, S
    Ramp, J
    Pacenti, D
    Barnes, W
    Doss, R
    Crowley, W
    Lehotay, DC
    George, S
    Eichhorst, J
    Ramsay, C
    Sluss, P
    CLINICA CHIMICA ACTA, 2005, 355 : S264 - S264
  • [48] EVALUATION OF A FLUORESCENCE POLARIZATION IMMUNOASSAY FOR DIGOXIN ON THE ABBOTT TDX ANALYZER
    FRYE, R
    PERLSTEIN, M
    KOTOWICZ, B
    LIJEWSKI, J
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1201 - 1201
  • [49] Evaluation of the Abbott i2000 immunoassay analyzer.
    Blick, KE
    Fry, HD
    Parker, KM
    Rollins, V
    CLINICAL CHEMISTRY, 2001, 47 (06) : A116 - A116
  • [50] AUTOMATED ENZYME-IMMUNOASSAY FOR LUTROPIN WITH THE ABBOTT IMX ANALYZER
    FORD, KA
    BAKER, HN
    BAAR, JG
    BALAY, D
    MARLEWSKI, D
    VENETUCCI, M
    OGUNRO, EA
    CLINICAL CHEMISTRY, 1989, 35 (12) : 2333 - 2335