Development of a quantitative vancomycin immunoassay for the Abbott AxSYM analyzer

被引:17
|
作者
Adamczyk, M
Brate, EM
Chiappetta, EG
Ginsburg, S
Hoffman, E
Klein, C
Perkowitz, MM
Rege, SD
Chou, PP
Costantino, AG
机构
[1] Abbott Labs, Abbott Diagnost Div, Abbott Pk, IL 60064 USA
[2] Amer Med Labs, Chantilly, VA USA
关键词
vancomycin; immunoassay; fluorescence; polarization; AxSYM analyzer;
D O I
10.1097/00007691-199804000-00010
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A novel fluorescence polarization immunoassay for vancomycin on Abbott AxSYM analyzer is described. The immunoassay allows for the accurate quantification of vancomycin in the presence of the crystalline degradation product (CDP). It displays dilution linearity from 1.0 mu g/ml to 100.0 mu g/ml, coefficients of variation ranging from 2.94% to 4.26%, recovery from 98% to 105%, and a sensitivity of <2.0 mu g/ml. The assay demonstrates no cross-reactivity to crystalline degradation product, and to commonly-prescribed and over-the-counter drugs, as well as a minimum interference from endogenous substances.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [21] Development and clinical evaluation of a recombinant-antigen-based cytomegalovirus immunoglobulin M automated immunoassay using the Abbott AxSYM analyzer
    Maine, GT
    Stricker, R
    Schuler, M
    Spesard, J
    Brojanac, S
    Iriarte, B
    Herwig, K
    Gramins, T
    Combs, B
    Wise, J
    Simmons, H
    Gram, T
    Lonze, J
    Ruzicki, D
    Byrne, B
    Clifton, JD
    Chovan, LE
    Wachta, D
    Holas, C
    Wang, D
    Wilson, T
    Tomazic-Allen, S
    Clements, MA
    Wright, GL
    Lazzarotto, T
    Ripalti, A
    Landini, MP
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (04) : 1476 - 1481
  • [22] Rapid, automated assay for progesterone on the Abbott AxSYM™ analyzer
    Wilson, DH
    Groskopf, W
    Hsu, S
    Caplan, D
    Langner, T
    Baumann, M
    DeManno, D
    Williams, G
    Payette, D
    Dagel, C
    Lynch, D
    Manderino, G
    CLINICAL CHEMISTRY, 1998, 44 (01) : 86 - 91
  • [23] An automated assay for progesterone on the Abbott AxSYM(TM) analyzer
    Wilson, DH
    Groskopf, W
    Hsu, S
    Caplan, D
    Langner, T
    DeManno, D
    Dagel, C
    Baumann, M
    Manderino, G
    CLINICAL CHEMISTRY, 1996, 42 (06) : 104 - 104
  • [24] Adaptation of total phenytoin reagent pack for measuring free phenytoin levels with the Abbott AxSYM immunoassay analyzer
    Jarzabek, JI
    Kampa, IS
    THERAPEUTIC DRUG MONITORING, 1999, 21 (01) : 134 - 136
  • [25] Preliminary clinical experience with Abbott AxSYM BNP immunoassay
    Piechota, WT
    Piechota, WN
    Adamus, J
    Jozefczak-Bergier, E
    Bejm, J
    Wadowska, E
    Raczka, A
    CLINICAL CHEMISTRY, 2004, 50 (06) : A10 - A10
  • [26] Development of a second generation Troponin I assay for the Abbott AxSYM® immunoassay system.
    Qui, KY
    Bouma, SR
    Sumerdon, GA
    Biegalski, TT
    Gardiner, ME
    Muñoz, JJ
    Peters, TL
    CLINICAL CHEMISTRY, 2003, 49 (06) : A62 - A62
  • [27] Development and multisite evaluation of an automated assay for B12 on the Abbott AxSYM analyzer
    Wilson, DH
    Yu, J
    Karian, A
    Kozlowski, J
    O'Reilly, S
    CLINICAL CHEMISTRY, 1999, 45 (03) : 428 - 429
  • [28] Lyme IgG and IgM assays for the Abbott AxSYM analyzer.
    Braun, HB
    Wind, T
    Staub, U
    Michel, G
    CLINICAL CHEMISTRY, 2000, 46 (06) : A53 - A53
  • [29] A multi-site evaluation of the Abbott AxSYM vancomycin II.
    Chou, PP
    Tsushima, JH
    Troxil, S
    Azzazy, HME
    Christenson, RH
    Chiappetta, E
    Avers, RJ
    CLINICAL CHEMISTRY, 1997, 43 : 476 - 476
  • [30] Abbott AxSYM vancomycin II assay: Multicenter evaluation and interference studies
    Azzazy, HME
    Chou, PP
    Tsushima, JH
    Troxil, S
    Gordon, M
    Avers, RJ
    Chiappetta, E
    Duh, SH
    Christenson, RH
    THERAPEUTIC DRUG MONITORING, 1998, 20 (02) : 202 - 208