Development of a quantitative vancomycin immunoassay for the Abbott AxSYM analyzer

被引:17
|
作者
Adamczyk, M
Brate, EM
Chiappetta, EG
Ginsburg, S
Hoffman, E
Klein, C
Perkowitz, MM
Rege, SD
Chou, PP
Costantino, AG
机构
[1] Abbott Labs, Abbott Diagnost Div, Abbott Pk, IL 60064 USA
[2] Amer Med Labs, Chantilly, VA USA
关键词
vancomycin; immunoassay; fluorescence; polarization; AxSYM analyzer;
D O I
10.1097/00007691-199804000-00010
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A novel fluorescence polarization immunoassay for vancomycin on Abbott AxSYM analyzer is described. The immunoassay allows for the accurate quantification of vancomycin in the presence of the crystalline degradation product (CDP). It displays dilution linearity from 1.0 mu g/ml to 100.0 mu g/ml, coefficients of variation ranging from 2.94% to 4.26%, recovery from 98% to 105%, and a sensitivity of <2.0 mu g/ml. The assay demonstrates no cross-reactivity to crystalline degradation product, and to commonly-prescribed and over-the-counter drugs, as well as a minimum interference from endogenous substances.
引用
收藏
页码:191 / 201
页数:11
相关论文
共 50 条
  • [1] Development of vancomycin_II (monoclonal) assay on the Abbott AxSYM(TM) immunoassay analyzer.
    Chiappetta, E
    Ginsburg, S
    Reische, C
    Brate, E
    Rege, S
    Adamczyk, M
    Aboleneen, H
    Sullins, V
    CLINICAL CHEMISTRY, 1996, 42 (06) : 540 - 540
  • [2] Development of Digitoxin assay for the Abbott AxSYM(R) immunoassay analyzer.
    Wang, C
    Jeng, KY
    Reische, C
    CLINICAL CHEMISTRY, 1996, 42 (06) : 505 - 505
  • [3] Development of procainamide assay for the Abbott AxSYM(R) immunoassay analyzer.
    Aviza, J
    Baer, T
    Burke, D
    Jenik, R
    CLINICAL CHEMISTRY, 1996, 42 (06) : 539 - 539
  • [4] Development and evaluation of an automated immunoassay for the determination of testosterone on the Abbott AxSYM® Analyzer
    Novotny, M
    Parsons, R
    Jenik, R
    Schultz, C
    Zuske, M
    Geekie, C
    Robertson, S
    CLINICAL CHEMISTRY, 2004, 50 (06) : A100 - A100
  • [5] An automated immunoassay. for the quantitative determination of intact PTH on the Abbott AxSYM™ analyzer.
    Anderson, R
    Gunasena, H
    Ranadive, G
    Krishna, R
    Bandla, M
    Bodani, U
    Mistry, J
    Weigand, R
    CLINICAL CHEMISTRY, 2000, 46 (06) : A124 - A124
  • [6] Development and evaluation of an automated immunoassay for the determination of intact PTH on the Abbott AxSYM® analyzer
    Hill, K
    Robertson, S
    Grant, L
    CLINICA CHIMICA ACTA, 2005, 355 : S247 - S247
  • [7] A microparticle enzyme immunoassay for the quantitative determination of intact PTH on the Abbott AxSYM analyzer.
    Gunasena, H
    Nunna, R
    Khaja, N
    Anderson, R
    Bodani, U
    Mistry, JS
    Rosierre, T
    Weigand, R
    CLINICAL CHEMISTRY, 2002, 48 (06) : A6 - A6
  • [8] An automated immunoassay for the determination of testosterone on the Abbott AxSYM® analyzer.
    Hales, BM
    Jeng, K
    Caplan, D
    Forsythe, C
    Weigand, R
    CLINICAL CHEMISTRY, 2002, 48 (06) : A134 - A135
  • [9] Development and evaluation of an automated immunoassay for the determination of D-dimer on the Abbott AXSYM® analyzer
    Robertson, S
    Taylor, V
    O'Kane, K
    McCourt, C
    Pritchard, D
    CLINICA CHIMICA ACTA, 2005, 355 : S231 - S231
  • [10] Development of N-acetylprocainamide assay for the Abbott AxSYM(R) immunoassay analyzer.
    Aviza, J
    Martinus, J
    Burke, D
    Jenik, R
    CLINICAL CHEMISTRY, 1996, 42 (06) : 541 - 541