A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication

被引:12
作者
Totuk, O. M. Gedar [1 ]
Kabadayi, K. [2 ]
Colakoglu, A. [2 ]
Ekizoglu, N. [2 ]
Aykan, U. [3 ]
机构
[1] Bahcesehir Univ, Fac Med, Dept Ophthalmol, Yenisahra Mah Batman Sok 66-68 Sahrayicedit, Istanbul, Turkey
[2] Bahcesehir Univ, Fac Med, Istanbul, Turkey
[3] Dunyagoz Hosp, FEBO, Istanbul, Turkey
关键词
Refractory glaucoma; Glaucoma valve tube exposure; Glaucoma valve implantation; Long scleral flap; Tenon duplication; Ahmed glaucoma valve; DRAINAGE DEVICE SURGERY; LATA PATCH GRAFT; IMPLANT; OUTCOMES; COMPLICATIONS; EXPERIENCE; TUNNEL;
D O I
10.1186/s12886-018-0907-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To describe a new technique and present its long-term outcome for prevention of Ahmed glaucoma valve (AGV) tube exposure in patients with refractory glaucoma. Methods: Twenty-seven eyes of 24 patients (mean age, 50 years; age range, 16-78 years; 8 females, 16 males) with refractory glaucoma who had the AGV implant were retrospectively reviewed. For AGV implantation, a long scleral flap combined with Tenon advancement and duplication was used. In this technique, a long scleral flap is created to completely cover the extraocular part of valve's tube, and the flap surface is covered with duplicated Tenon's tissue. The average follow-up after AGV implantation was 21.7 months (range, 12-36 months). Results: The mean intraocular pressure before the operation, which was 44.1 mmHg (range, 26-62 mmHg), decreased to 14.2 mmHg (range, 8-20 mmHg) at the last follow-up visit, showing 67% reduction with AGV implantation. The mean number of antiglaucomatous medications was 4.1 before the AGV implantation and decreased to 0.9 after the operation, showing 88% reduction. In 14 eyes (51.9%), there was no change in the best corrected visual acuity (BCVA), and in 11 eyes (40.7%), the BCVA increased by 2 lines on the Snellen chart postoperatively. No patient developed postoperative hypotony, flat anterior chamber, diplopia, strabismus, erosion or exposure of the tube, or tube/plate migration. Conclusions: The long scleral flap augmented with Tenon advancement and duplication is an effective and safe surgical technique for the implantation of AGV and preventing tube exposure in cases of refractory glaucoma.
引用
收藏
页数:8
相关论文
共 28 条
[1]   A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery [J].
Ainsworth, G ;
Rotchford, A ;
Dua, HS ;
King, AJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (04) :417-419
[2]   Endophthalmitis associated with the Ahmed glaucoma valve implant [J].
Al-Torbak, AA ;
Al-Shahwan, S ;
Al-Jadaan, I ;
Al-Hommadi, A ;
Edward, DP .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (04) :454-458
[3]  
Bikbov Mukharram Mukhtaramovich, 2015, J Curr Glaucoma Pract, V9, P86, DOI 10.5005/jp-journals-10008-1191
[4]   "Double scleral tunnel in tandem" technique for glaucoma drainage tube implants [J].
Brouzas, Dimitrios ;
Dettoraki, Maria ;
Andreanos, Konstantinos ;
Nomikarios, Nikolaos ;
Koutsandrea, Chryssanthi ;
Moschos, Marilita M. .
INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (06) :2349-2356
[5]   Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery [J].
Chaku, Meenakshi ;
Netland, Peter A. ;
Ishida, Kyoko ;
Rhee, Douglas J. .
CLINICAL OPHTHALMOLOGY, 2016, 10 :547-553
[6]   Our experience of fibrin sealant-assisted implantation of Ahmed glaucoma valve [J].
Choudhari, Nikhil S. ;
Neog, Aditya ;
Sharma, Anuj ;
Iyer, Geetha K. ;
Srinivasan, Bhaskar .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (01) :23-27
[7]   The Ahmed Versus Baerveldt Study One-Year Treatment Outcomes [J].
Christakis, Panos G. ;
Kalenak, Jeffrey W. ;
Zurakowski, David ;
Tsai, James C. ;
Kammer, Jeffrey A. ;
Harasymowycz, Paul J. ;
Ahmed, Iqbal I. K. .
OPHTHALMOLOGY, 2011, 118 (11) :2180-2189
[8]   Complications of Glaucoma Drainage Device Surgery: A Review [J].
Giovingo, Michael .
SEMINARS IN OPHTHALMOLOGY, 2014, 29 (5-6) :397-402
[9]   Long-term persistence of fascia lata patch graft in glaucoma drainage device surgery [J].
Gutiérrez-Díaz, E ;
Montero-Rodríguezi, M ;
Mencía-Gutiérrezi, E ;
Cabello, A ;
Monescillo, J .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (03) :412-414
[10]   Aqueous shunt tube erosion [J].
Heuer, DK ;
Budenz, D ;
Coleman, A .
JOURNAL OF GLAUCOMA, 2001, 10 (06) :493-496