Resonant neutral-particle emission in collisions of electrons with peptide ions in a storage ring

被引:37
|
作者
Tanabe, T [1 ]
Noda, K
Saito, M
Lee, S
Ito, Y
Takagi, H
机构
[1] KEK, High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[2] Natl Inst Radiol Sci, Chiba 2638555, Japan
[3] Kyoto Prefectural Univ, Kyoto 6068522, Japan
[4] Kitasato Univ, Ctr Nat Sci, Sagamihara, Kanagawa 2288555, Japan
关键词
D O I
10.1103/PhysRevLett.90.193201
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Electron-biomolecular ion collisions were studied using an electrostatic storage ring with a merging beam technique for singly protonated peptides (angiotensin I, II, and III). A strong neutral-particle emission at around 6.5 eV was found in addition to neutrals from recombination at low energies. The rates of the high-energy peak greatly decreased with a slight decrease in the number of amino-acid residues from angiotensin I to III. These results suggest that some peptide bonds were selectively cleaved.
引用
收藏
页码:1 / 193201
页数:4
相关论文
共 38 条
  • [21] SURFACE EMISSION OF NEGATIVE-IONS FOR LOW-ENERGY NEUTRAL PARTICLE DETECTORS
    HISKES, JR
    KARO, AM
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (05): : 702 - 702
  • [22] Interplay between emission of electrons and quasi-resonant ultrafast electron tunneling in cluster-surface collisions
    Speer, O
    Garcia, ME
    Wrenger, B
    Meiwes-Broer, KH
    SURFACE SCIENCE, 1999, 443 (03) : 195 - 211
  • [23] ASTRID - THE AARHUS DUAL-PURPOSE STORAGE-RING FOR POSITIVE/NEGATIVE IONS AND ELECTRONS
    UGGERHOJ, E
    JOURNAL DE PHYSIQUE IV, 1994, 4 (C9): : 349 - 356
  • [24] Forward electron emission in collisions of He2+ ions with Ar atoms with simultaneous capture of two electrons
    Sarkadi, L.
    Nagy, D.
    PHYSICAL REVIEW A, 2016, 94 (04)
  • [25] Electron capture induced dissociation of peptide ions: Identification of neutral fragments from secondary collisions with cesium vapor
    Hvelplund, Preben
    Liu, Bo
    Brondsted Nielsen, Steen
    Panja, Subliasis
    Poully, Jean-Christophe
    Stochkel, Kristian
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 263 (01) : 66 - 70
  • [26] Investigations of the decay of fullerene ions in a storage ring, and of delayed ionization of neutral fullerenes measured by time of flight
    Andersen, JU
    Hvelplund, P
    Nielsen, SB
    Tomita, S
    FULLERENES AND NANOTUBES: THE BUILDING BLOCKS OF NEXT GENERATION NANODEVICES, 2003, 2003 (15): : 449 - 452
  • [27] SURFACE EMISSION OF NEGATIVE-IONS FOR LOW-ENERGY NEUTRAL PARTICLE DETECTORS .2.
    HISKES, JR
    SCHNEIDER, PJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (06): : 698 - 698
  • [28] PEPTIDE SEQUENCE IONS PRODUCED BY POSTIONIZATION OF NEUTRAL MOLECULES FORMED DURING RESONANT 266-NM LASER DESORPTION
    KINSEL, GR
    LINDNER, J
    GROTEMEYER, J
    JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (07): : 3157 - 3162
  • [29] Development of particle detectors for electron-ion collision spectroscopy with highly charged ions at the storage ring
    Huang, Z. K.
    Khan, N.
    Wang, S. X.
    Wen, W. Q.
    Wang, H. B.
    Ma, W. L.
    Shao, L.
    Huang, H. K.
    Liu, X.
    Chen, D. Y.
    Zhou, X. P.
    Zhao, D. M.
    Yang, H. R.
    Mao, L. J.
    Ma, X. M.
    Li, J.
    Tang, M. T.
    Zhou, Y. B.
    Yan, K. M.
    Yin, D. Y.
    Yang, J. C.
    Yuan, Y. J.
    Zhang, S. F.
    Zhu, L. F.
    Ma, X.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [30] Particle detectors for beam diagnosis and for experiments with stable and radioactive ions in the storage-cooler ring ESR
    Klepper, O
    Kozhuharov, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 204 : 553 - 556