Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template

被引:10
|
作者
Pu, Xingwei [1 ]
Luo, Chunshan [1 ]
Lu, Tinsheng [1 ]
Yao, Shudan [1 ]
Chen, Qiling [1 ]
机构
[1] Guizhou Orthoped Hosp, Dept Spinal Surg, Guiyang 550002, Guizhou, Peoples R China
关键词
Atlantoaxial; Improvement; Navigation Template; 3D Print; Pedicle Screw; ACCURACY;
D O I
10.6061/clinics/2018/e259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: To investigate the primary clinical value of atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. METHODS: We retrospectively analyzed the cases of 17 patients treated from June 2015 to September 2016 with atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. All procedures were performed prior to surgery, including thin-slice CT scanning, medical image sampling and computerized 3D modeling of the atlantoaxial joint, optimal pedicle screw trajectory determination, and anatomical trait acquisition for the atlantoaxial pedicle, spinous process of the axis, vertebral lamina and posterior lateral mass, and design of a reverse template. During surgery, a navigation template was tightly attached to the atlantoaxial joint to assist in pedicle screw placement. Surgeons subsequently used an electric drill to remove the template through a guide channel and then placed the atlantoaxial pedicle screw. Observed indexes included the VAS score, JOA improvement rate, surgery duration, and blood loss. RESULTS: Surgery was successful in all 17 patients, with an average operation duration of 106 +/- 25 min and an average blood loss of 220 +/- 125 ml. Three days postoperatively, the VAS score decreased from 6.42 +/- 2.21 to 3.15 +/- 1.26. Six months postoperatively, the score decreased to 2.05 +/- 1.56. The postoperative JOA score increased significantly from 7.68 +/- 2.51 to 11.65 +/- 2.72 3 d after surgery and to 13.65 +/- 2.57 after 6 months. Sixtyeight pedicle screws were inserted successfully, with 34 in the atlas and 34 in the axis. According to the Kawaguchi standard, 66 screws were in grade 0 (97.06%), and 2 were in grade 1 (2.94%). The pre- and postoperative transverse and sagittal screw angles showed no significant differences. CONCLUSIONS: Atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template is worth recommending due to the improved accuracy in screw placement, improved patient safety and beneficial clinical effects.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation
    Tian, Ye
    Zhang, Jianan
    Liu, Tuanjiang
    Tang, Shi
    Chen, Hao
    Ding, Keyuan
    Hao, Dingjun
    MEDICAL SCIENCE MONITOR, 2019, 25 : 9981 - 9990
  • [22] 3D-printed navigation template in cervical spine fusion: a systematic review and meta-analysis
    Azimi, Parisa
    Yazdanian, Taravat
    Benzel, Edward C.
    Azimi, Ali
    Montazeri, Ali
    EUROPEAN SPINE JOURNAL, 2021, 30 (02) : 389 - 401
  • [23] Enhancing the Accuracy of Pedicle Screw Placement Using 3D-Printed Screw-Guiding Techniques in the Lumbosacral Region for Small Breed Dogs: A Cadaveric Study
    Kim, Jin-Yeong
    Kwak, Ho-Hyun
    Woo, Heung-Myong
    Kim, Junhyung
    ANIMALS, 2025, 15 (01):
  • [24] Design and Application of a Novel Patient-Specific Three-Dimensional Printed Drill Navigational Guiding in Atlantoaxial Pedicle Screw Placement
    Pu, Xinwei
    Yin, Mengchen
    Ma, Junming
    Liu, Yujie
    Chen, Guanghui
    Huang, Quan
    Zhao, Guoquan
    Lu, Tingsheng
    Yao, Shudan
    Chen, Qinlin
    Luo, Chunshan
    WORLD NEUROSURGERY, 2018, 114 : E1 - E10
  • [25] Accuracy Assessment of Pedicle and Lateral Mass Screw Insertion Assisted by Customized 3D-Printed Drill Guides: A Human Cadaver Study
    Pijpker, Peter A. J.
    Kraeima, Joep
    Witjes, Max J. H.
    Oterdoom, D. L. Marinus
    Coppes, Maarten H.
    Groen, Rob J. M.
    Kuijlen, Jos M. A.
    OPERATIVE NEUROSURGERY, 2019, 16 (01) : 94 - 102
  • [26] Clinical application of 3D printing in pedicle screw fixation and fusion for the treatment of old type II odontoid fractures with posterior atlantoaxial dislocation
    Xiong, Moliang
    Chen, Ruisong
    Jian, Guojian
    Xia, Tao
    Liao, Xin
    Ye, Zhiyang
    Xu, Tianrui
    Huang, Jianming
    Huang, Yanpeng
    Feng, Zhijun
    Li, Yanfang
    Zheng, Honghua
    Wang, Zimin
    Liu, Haoyuan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (07): : 11244 - 11253
  • [27] Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template
    Zhao, Yonghui
    Luo, Haotian
    Ma, Yulong
    Liang, Jinlong
    Han, Gonghai
    Xu, Yongqing
    Lu, Sheng
    WORLD NEUROSURGERY, 2021, 146 : E161 - E167
  • [28] Comparison of the Accuracy and Safety of Pedicle Screw Placement in Thoracic Spine Between 3D Printed Navigation Templates and Free Hand Technique
    Kovalenko, R. A.
    Ptashnikov, D. A.
    Cherebillo, V. Yu
    Kashin, V. A.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2020, 26 (03): : 49 - 60
  • [29] Facet Violation With Percutaneous Pedicle Screw Placement: Impact of 3D Navigation and Facet Orientation
    Cong, Ting
    Sivaganesan, Ahilan
    Mikhail, Christopher M.
    Vaishnav, Avani S.
    Dowdell, James, III
    Barbera, Joseph
    Kumagai, Hiroshi
    Markowitz, Jonathan
    Sheha, Evan
    Qureshi, Sheeraz A.
    HSS JOURNAL, 2021, 17 (03) : 281 - 288
  • [30] Accuracy of Patient-Specific, 3D-Printed Laminofacetal Based Trajectory-Guide for Pedicle Screw Placement in Subaxial Cervical and Thoracic Spine
    Kashyap, Abhishek
    Karim, Adil
    Arora, Sumit
    Singh, Keshave
    Jha, Sunil
    Maini, Lalit
    NEUROLOGY INDIA, 2023, 71 (02) : 260 - 266