Simulation Response of He-3 Filled Proportional Counter for Thermal Neutrons

被引:0
|
作者
Jamil, M. [1 ]
Rhee, J. T. [2 ]
Kim, H. G. [2 ]
机构
[1] Konkuk Univ, Div Int Studies, Seoul 143701, South Korea
[2] Konkuk Univ, Inst Adv Phys, Dept Phys, Seoul 143701, South Korea
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
He-3 filled proportional counter is very useful detector for thermal and low energy neutron detection. The proportional counter filled with He-3 is considered an ideal detector for the thermal neutron detection, as He-3 has a large neutron cross-section and it is relatively insensitive to gamma-rays. Further, such a counter can be operated at a lower voltage, and it can withstand extreme radiation environments. In the present work, the response of a He-3 proportional counter evaluated via the simulation approach has been reported. For the test, a tube with 5 cm diameter and 5 cm length has been designed and filled with He-3 gas. The response of the detector has been evaluated for the thermal neutrons in the energy ranges of 1.0 meV to 100 meV ranges. The higher obtained response confirmed that such a counter can utilized for the thermal neutron detection.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] SPHERICAL PROPORTIONAL COUNTER FILLED WITH HE-3
    KOROLEV, VI
    SAVINSKI.AK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (01): : 71 - &
  • [2] NEUTRON RESPONSE OF AN HE-3 PROPORTIONAL COUNTER
    DIETZ, E
    MATZKE, M
    SOSAAT, W
    URBACH, G
    WEYRAUCH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (03): : 521 - 528
  • [3] LOW VOLTAGE HE3-FILLED PROPORTIONAL COUNTER FOR EFFICIENT DETECTION OF THERMAL AND EPITHERMAL NEUTRONS
    MILLS, WR
    CALDWELL, RL
    MORGAN, IL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (08): : 866 - &
  • [4] DEVELOPMENT OF POSITION-SENSITIVE HE-3 PROPORTIONAL COUNTER FOR THERMAL-NEUTRONS WITH NOVEL SIGNAL READOUT
    URITANI, A
    MORI, C
    WATANABE, T
    MIYAHARA, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1990, 27 (08) : 712 - 717
  • [6] PULSE RISETIME ANALYSIS OF A HE-3 PROPORTIONAL COUNTER
    IZUMI, S
    MURATA, Y
    NUCLEAR INSTRUMENTS & METHODS, 1971, 94 (01): : 141 - &
  • [7] Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters
    Kudo, K
    Takeda, N
    Uritani, A
    Koshikawa, S
    Shibata, Y
    Kobayashi, K
    Yoshimoto, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 305 - 309
  • [8] HE-3 FILLED PROPORTIONAL COUNTERS AS NEUTRON SPECTROMETERS
    DELAUNE, CI
    NELSON, JW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (04): : 650 - &
  • [9] 3HE-NE-CH4 MIXTURES IN PROPORTIONAL COUNTER FOR THERMAL NEUTRONS
    KROHN, VE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 853 - &
  • [10] RADIATION-DAMAGE TO HE-3 PROPORTIONAL COUNTER TUBES
    EVANS, AE
    MENLOVE, HO
    WALTON, RB
    SMITH, DB
    NUCLEAR INSTRUMENTS & METHODS, 1976, 133 (03): : 577 - 578