Mueller matrix imaging of human colon tissue for cancer diagnostics: how Monte Carlo modeling can help in the interpretation of experimental data

被引:164
作者
Antonelli, Maria-Rosaria [1 ]
Pierangelo, Angelo [1 ]
Novikova, Tatiana [1 ]
Validire, Pierre [2 ]
Benali, Abdelali [2 ]
Gayet, Brice [3 ]
De Martino, Antonello [1 ]
机构
[1] Ecole Polytech, CNRS, LPICM, F-91128 Palaiseau, France
[2] Inst Mutualiste Montsouris, Dept Anatomopathol, F-75014 Paris, France
[3] Inst Mutualiste Montsouris, Dept Medicochirurg Pathol Digest, F-75014 Paris, France
来源
OPTICS EXPRESS | 2010年 / 18卷 / 10期
关键词
POLARIZED-LIGHT; SCATTERING MEDIA; DIFFUSE BACKSCATTERING; TURBID MEDIA; PROPAGATION; REFLECTANCE; SUSPENSIONS; PHANTOMS; CELLS; SIZE;
D O I
10.1364/OE.18.010200
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Colon samples with both healthy and cancerous regions have been imaged in diffuse light and backscattering geometry by using a Mueller imaging polarimeter. The tumoral parts at the early stage of cancer are found to be less depolarizing than the healthy ones. This trend clearly shows that polarimetric imaging may provide useful contrasts for optical biopsy. Moreover, both types of tissues are less depolarizing when the incident polarization is linear rather than circular. However, to really optimize an optical biopsy technique based on polarimetric imaging a realistic model is needed for polarized light scattering by tissues. Our approach to this goal is based on numerical Monte-Carlo simulations of polarized light propagation in biological tissues modeled as suspensions of monodisperse spherical scatterers representing the cell nuclei. The numerical simulations were validated by comparison with measurements on aqueous polystyrene sphere suspensions, which are commonly used as tissue phantoms. Such systems exhibit lower depolarization for incident linear polarization in the Rayleigh scattering regime, i.e. when the sphere diameters are smaller than the wavelength, which is obviously not the case for cell nuclei. In contrast, our results show that this behaviour can also be seen for "large" scatterers provided the optical index contrast between the spheres and the surrounding medium is small enough, as it is likely to be the case in biological tissues. (C)2010 Optical Society of America
引用
收藏
页码:10200 / 10208
页数:9
相关论文
共 26 条
  • [1] Experimental validation of the reverse polar decomposition of depolarizing Mueller matrices
    Anastasiadou, Makrina
    Hatit, Sami Ben
    Ossikovski, Razvigor
    Guyot, Steve
    De Martino, Antonello
    [J]. JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2007, 2
  • [2] Monte Carlo simulations of the diffuse backscattering Mueller matrix for highly scattering media
    Bartel, S
    Hielscher, AH
    [J]. APPLIED OPTICS, 2000, 39 (10) : 1580 - 1588
  • [3] DEPOLARIZATION OF MULTIPLY SCATTERED WAVES BY SPHERICAL DIFFUSERS - INFLUENCE OF THE SIZE PARAMETER
    BICOUT, D
    BROSSEAU, C
    MARTINEZ, AS
    SCHMITT, JM
    [J]. PHYSICAL REVIEW E, 1994, 49 (02): : 1767 - 1770
  • [4] Bohren C F, 2004, ABSORPTION SCATTERIN
  • [5] Monte Carlo study of pathlength distribution of polarized light in turbid media
    Guo, Xinxin
    Wood, Michael F. G.
    Vitkin, Alex
    [J]. OPTICS EXPRESS, 2007, 15 (03): : 1348 - 1360
  • [6] Modelling and validation of spectral reflectance for the colon
    Hidovic-Rowe, D
    Claridge, E
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (06) : 1071 - 1093
  • [7] HIDOVICROWE D, 2006, MED IMAGE UNDERSTAND, V1, P66
  • [8] Influence of particle size and concentration on the diffuse backscattering of polarized light from tissue phantoms and biological cell suspensions
    Hielscher, AH
    Mourant, JR
    Bigio, IJ
    [J]. APPLIED OPTICS, 1997, 36 (01) : 125 - 135
  • [9] Diffuse backscattering Mueller matrices of highly scattering media
    Hielscher, Andreas H.
    Eick, Angelia A.
    Mourant, Judith R.
    Shen, Dan
    Freyer, James P.
    Bigio, Irving J.
    [J]. OPTICS EXPRESS, 1997, 1 (13): : 441 - 453
  • [10] Jacques S.L., 2008, Proc. of SPIE, V6842, p68420I