Factors affecting the relationship between arterial and end-tidal carbon dioxide pressures in the anaesthetised horse

被引:6
|
作者
Rainger, J. E. [1 ]
Dart, C. M. [1 ]
Perkins, N. R. [2 ]
机构
[1] Univ Sydney, Univ Vet Teaching Hosp Camden, Camden, NSW 2570, Australia
[2] AusVet Anim Hlth Serv, Toowoomba, Qld, Australia
关键词
anaesthesia; arterial blood gas analysis; carbon dioxide; end-tidal volume; horses; recumbency; ventilation; LATERALLY RECUMBENT HORSES; ALVEOLAR DEAD SPACE; CONTROLLED VENTILATION; HALOTHANE ANESTHESIA; EMERGENCY-MEDICINE; GAS-EXCHANGE; CO2; TENSION; ISOFLURANE; MODE; DIFFERENCE;
D O I
10.1111/j.1751-0813.2009.00535.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To assess the effects of the duration of anaesthesia, position of recumbency, mode of ventilation, anaesthetic drug protocol, patient age and type of surgical procedure on the usefulness of capnometry as a measure of the partial pressure of arterial carbon dioxide (PaCO2) during general anaesthesia in horses. Design A prospective study compared the PaCO2 values with those of partial pressure of end-tidal carbon dioxide (ETCO2) in horses anaesthetised for elective or emergency surgical procedures. The difference between PaCO2 and ETCO2 (PaCO2 - ETCO2) and the physiological dead space to tidal volume ratio (V-D/V-T) were calculated. The effects of the study parameters on these variables was determined. Results The agreement between PaCO2 and ETCO2 was poor. PaCO2 - ETCO2 and V-D/V-T during the first 60 min of anaesthesia was significantly less than after 60 min of anaesthesia. Mode of ventilation, position of recumbency, anaesthetic drug protocol, patient age and type of procedure did not have a significant affect on either value. Conclusions PaCO2 - ETCO2 in anaesthetised horses can be large, making ETCO2 unreliable as a predictor Of PaCO2 and for assessment of pulmonary ventilation. For anaesthesia lasting less than 60 min at least one blood gas analysis of an arterial blood sample is required to assess PaCO2 - ETCO2. Arterial blood gas analysis should be repeated after 60 min of general anaesthesia.
引用
收藏
页码:13 / 19
页数:7
相关论文
共 50 条
  • [31] STABILITY OF ARTERIAL TO END-TIDAL CARBON-DIOXIDE GRADIENTS DURING POSTOPERATIVE CARDIORESPIRATORY SUPPORT
    RUSSELL, GB
    GRAYBEAL, JM
    STROUT, JC
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1990, 37 (05): : 560 - 566
  • [32] End-tidal carbon dioxide as a goal of early sepsis therapy
    Guirgis, Faheem W.
    Williams, Deborah J.
    Kalynych, Colleen J.
    Hardy, Mary E.
    Jones, Alan E.
    Dodani, Sunita
    Wears, Robert L.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (11) : 1351 - 1356
  • [33] End-tidal carbon dioxide measurement and breathing system filters
    Hardman, JG
    Curran, J
    Mahajan, RP
    ANAESTHESIA, 1997, 52 (07) : 646 - 648
  • [34] Comparison of the arterial blood gas, arterial oxyhaemoglobin saturation and end-tidal carbon dioxide tension during sevoflurane or isoflurane anaesthesia in rabbits
    Topal, A
    Gül, N
    IRISH VETERINARY JOURNAL, 2006, 59 (05) : 278 - 281
  • [35] SENSITIVITY OF A DISPOSABLE END-TIDAL CARBON-DIOXIDE DETECTOR
    JONES, BR
    DORSEY, MJ
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (03): : 268 - 270
  • [36] Acute breathlessness measured by clamping the end-tidal carbon dioxide
    Pickering, E
    Nazir, MS
    Guz, A
    Semple, S
    Murphy, K
    Holdcroft, A
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (03) : 400P - 401P
  • [37] End-tidal carbon dioxide monitoring during procedural sedation
    Miner, JR
    Heegaard, W
    Plummer, D
    ACADEMIC EMERGENCY MEDICINE, 2002, 9 (04) : 275 - 280
  • [38] Comparison of the arterial blood gas, arterial oxyhaemoglobin saturation and end-tidal carbon dioxide tension during sevoflurane or isoflurane anaesthesia in rabbits
    Ayse Topal
    Nihal Gül
    Irish Veterinary Journal, 59
  • [39] Initial end-tidal carbon dioxide as a prognostic indicator for inpatient PEA arrest
    Pearce, Alex K.
    Davis, Daniel P.
    Minokadeh, Anushirvan
    Sell, Rebecca E.
    RESUSCITATION, 2015, 92 : 77 - 81
  • [40] ACCURACY OF END-TIDAL CARBON-DIOXIDE TENSION ANALYZERS
    RAEMER, DB
    CALALANG, I
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 195 - 208