Na18F accumulates on the compressive side of peri-implant bone under immediate loading

被引:3
|
作者
Yamamoto, Miou [1 ]
Ogawa, Toru [1 ]
Yokoyama, Masayoshi [1 ]
Funaki, Yoshihito [2 ]
Shobara, Kenta [1 ]
Shibamoto, Aya [1 ]
Saenz, Juan Ramon Vanegas [1 ]
Sasaki, Keiichi [1 ]
机构
[1] Tohoku Univ, Grad Sch Dent, Div Adv Prosthet Dent, Aoba Ku, 4-1 Seiryo Machi, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Ctr Cyclotron & Radioisotope, Sendai, Miyagi, Japan
关键词
Bone metabolism; Peri-implant bone; (NaF)-F-18-PET; Immediate loading; Animal study; METABOLIC-ACTIVITY; DENTAL IMPLANTS; PET; SCINTIGRAPHY; RESOLUTION; ION;
D O I
10.1007/s10266-017-0327-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to examine the dynamic change in bone metabolism by immediate loading in several sites around implants using high-resolution (NaF)-F-18-PET scan. Two titanium implants ( 1.2 mm) were inserted parallel to each other in the right tibiae of Wistar rats (n = 4). The left tibia was set as control side. One day after insertion, closed coil springs of 4.0 N were attached to the expose superior portions of the implants to apply a continuous mechanical stress. The rats with fluorine-18 (F-18) ion (5 mCi/rat) intravenously injected were scanned by PET scanner at 4, 7, 14, 28 days after load application. Round region of interests (ROIs) were set around the distal implant of the right tibia (loaded side) and same site (control) of the left tibia. Furthermore, four rectangular ROIs were set at the superior and inferior parts of traction side (mesial) and opposite side (distal) of the distal implant. Longitudinal dynamic changes in bone metabolism were evaluated by examination of the accumulation count of F-18 ion at each ROI. The uptake values of ROIs (loaded side) initially increased until 7 days, and they gradually decreased from the peak level to the pre-loading level despite a static force being applied to the implants. In cancellous bone, the uptake values at the superior part of traction side and inferior part of opposite side showed significantly high value compared with those at other parts. In conclusion, immediate loading to the implant initially enhanced bone metabolism around it, especially at the part with compressive stress. Peri-implant bone metabolism varies according to different loading conditions.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 50 条
  • [1] Na18F accumulates on the compressive side of peri-implant bone under immediate loading
    Miou Yamamoto
    Toru Ogawa
    Masayoshi Yokoyama
    Yoshihito Funaki
    Kenta Shobara
    Aya Shibamoto
    Juan Ramón Vanegas Sáenz
    Keiichi Sasaki
    Odontology, 2018, 106 : 232 - 237
  • [2] Evaluation of peri-implant bone metabolism under immediate loading using high-resolution Na18F-PET
    Matsuo, Yutaka
    Ogawa, Toru
    Yamamoto, Miou
    Shibamoto, Aya
    Saenz, Juan Ramon Vanegas
    Yokoyama, Masayoshi
    Kanda, Yoshiaki
    Toyohara, Jun
    Sasaki, Keiichi
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (06) : 2029 - 2037
  • [3] Evaluation of peri-implant bone metabolism under immediate loading using high-resolution Na18F-PET
    Yutaka Matsuo
    Toru Ogawa
    Miou Yamamoto
    Aya Shibamoto
    Juan Ramón Vanegas Sáenz
    Masayoshi Yokoyama
    Yoshiaki Kanda
    Jun Toyohara
    Keiichi Sasaki
    Clinical Oral Investigations, 2017, 21 : 2029 - 2037
  • [4] Influence of controlled immediate loading and implant design on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Geris, Liesbet
    Vander Sloten, Jozef
    Puers, Robert
    Duyck, Joke
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (02) : 172 - 181
  • [5] Influence of immediate implant loading on peri-implant soft tissue morphology in the edentulous maxilla
    Gallucci, German O.
    Mavropoulos, Anestis
    Bernard, Jean-Pierre
    Belser, Urs C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (04) : 595 - 602
  • [6] Peri-Implant Bone Organization under Immediate Loading Conditions: Collagen Fiber Orientation and Mineral Density Analyses in the Minipig Model
    Traini, Tonino
    Neugebauer, Jorg
    Thams, Ulf
    Zoeller, Joachim E.
    Caputi, Sergio
    Piattelli, Adriano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (01) : 41 - 51
  • [7] Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla
    Barbier, Lieven
    Abeloos, Johan
    De Clercq, Calix
    Jacobs, Reinhilde
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (04) : 1061 - 1070
  • [8] The influence of immediate occlusal loading on micro/nano-structure of peri-implant jaw bone in rats
    Yorioka, Hiroaki
    Otsu, Yuto
    Suzuki, Ryu
    Matsunaga, Satoru
    Nakano, Takayoshi
    Abe, Shinichi
    Sasaki, Hodaka
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [9] Peri-implant bone organization under immediate loading state.: Circularly polarized light analyses:: A minipig study
    Neugebauer, Joerg
    Traini, Tonino
    Thams, Ulf
    Piattelli, Adriano
    Zoeller, Joachim E.
    JOURNAL OF PERIODONTOLOGY, 2006, 77 (02) : 152 - 160
  • [10] Effect of implant surface roughness and loading on peri-implant bone formation
    Vandamme, Katleen
    Naert, Ignace
    Sloten, Jozef Vander
    Puers, Robert
    Duyck, Joke
    JOURNAL OF PERIODONTOLOGY, 2008, 79 (01) : 150 - 157