Shear bond strength fatigue limit of rest seats made with dental restoratives

被引:0
作者
Scarelli Lopes, Jose Fernando
Vergani, Carlos Eduardo
Giampaolo, Eunice Teresinha
Pavarina, Ana Claudia
Machado, Ana Lucia
机构
[1] Univ Estadual Paulista, Fac Odontol Araraquara, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 Sao Paulo, Brazil
[2] Univ Sagrado Coracao, Dept Prosthodont, Bauru, Brazil
关键词
glass-ionomer cements; composite resins; fatigue; shear bond strength; dental bonding;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study compared the shear bond strength (SBS) to enamel of rest seats made with a glass-ionomer cement (Fuji IX GP Fast), a resin-modified glass-ionomer cement (Fuji 11 LC), and a composite resin (Z100 MP) under monotonic and cyclic loading. Materials and Methods: Rest seats were built up onto the lingual surfaces of 80 intact human mandibular incisors. Specimens (n=10) were stored in distilled water at 37 degrees C for 30 days and subjected to shear forces in a universal testing machine (0.5 mm/min) until fracture. The SBS values were calculated (MPa) using the bonding area (9.62 mm(2)) delimited by adhesive tags. A staircase approach was used to determine the SBS fatigue limit of each material. Specimens were submitted to either 10,000 cycles (5 Hz) or until specimen fracture. A minimum of 15 specimens was tested for each material. Scanning electron microscopy was used to examine the mode of failure. Data were statistically analyzed with one-way ANOVA and Tukey HSD tests (alpha = 0.05). Results: Z100 MP yielded higher (p < 0.05) SBS (12.25 MPa) than Fuji IX GP Fast (7.21 MPa). No differences were found between Fuji 11 LC (10.29 MPa) and the other two materials (p > 0.05). Fuji 11 LC (6.54 MPa) and Z100 MP (6.26 MPa) had a similar SBS limit. Fuji IX GP Fast promoted the lowest (p < 0.05) SBS fatigue limit (2.33 MPa). All samples showed cohesive failure patterns. Conclusion: Fatigue testing can provide a better means of estimating the performance of rest seats made with dental restoratives.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 43 条
  • [1] The relationship between water absorption characteristics and the mechanical strength of resin-modified glass-ionomer cements in long-term water storage
    Akashi, A
    Matsuya, Y
    Unemori, M
    Akamine, A
    [J]. BIOMATERIALS, 1999, 20 (17) : 1573 - 1578
  • [2] Bates J F, 1976, J Oral Rehabil, V3, P57, DOI 10.1111/j.1365-2842.1976.tb00929.x
  • [3] CARIES, PERIODONTAL AND PROSTHETIC FINDINGS IN PATIENTS WITH REMOVABLE PARTIAL DENTURES - A 10-YEAR LONGITUDINAL-STUDY
    BERGMAN, B
    HUGOSON, A
    OLSSON, CO
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1982, 48 (05) : 506 - 514
  • [4] IN-VITRO FATIGUE BEHAVIOR OF RESTORATIVE COMPOSITES AND GLASS IONOMERS
    BRAEM, MJA
    LAMBRECHTS, P
    GLADYS, S
    VANHERLE, G
    [J]. DENTAL MATERIALS, 1995, 11 (02) : 137 - 141
  • [5] COLLINS JA, 1993, FAILURE MAT MECH DES, P383
  • [6] COURY TL, 1982, OPER DENT, V7, P2
  • [7] Bond strength of Bis-GMA and glass ionomer pit and fissure sealants using cyclic fatigue
    Dewji, HR
    Drummond, JL
    Fadavi, S
    Punwani, I
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (01) : 594 - 599
  • [8] DIETER GE, 1961, MECH METALLURGY, P446
  • [9] A METHOD FOR OBTAINING AND ANALYZING SENSITIVITY DATA
    DIXON, WJ
    MOOD, AM
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1948, 43 (241) : 109 - 126
  • [10] COMPRESSIVE FATIGUE LIMITS OF COMPOSITE RESTORATIVE MATERIALS
    DRAUGHN, RA
    [J]. JOURNAL OF DENTAL RESEARCH, 1979, 58 (03) : 1093 - 1096