Push-out tests on three innovative shear connectors for composite cold-formed steel concrete beams

被引:31
作者
Bamaga, S. O. [1 ]
Tahir, M. M. [2 ]
Tan, C. S. [2 ]
Shek, P. N. [2 ]
Aghlara, R. [2 ]
机构
[1] Univ Bisha, Coll Engn, Dept Civil Engn, Bisha 61922, Saudi Arabia
[2] Univ Teknol Malaysia, ISIIC, CRC, Sch Civil Engn, Johor Baharu 81310, Johor, Malaysia
关键词
Cold-formed steel section; Composite beam; Push test; Shear connector; Ductility; Composite action; FEASIBILITY; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2019.06.223
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The composite action between concrete and steel makes the use of composite beams in buildings more economical than the use of typical hot-rolled steel beams. This can be attributed to the beam's lower depth, which significantly reduces the weight of steel. Composite beams can be constructed by lipped C-channels made from cold-formed steel, concrete, and different shear connectors (which exhibit behaviours that are not yet well understood). In this study, the behaviour of three innovative shear connectors used in composite cold-formed steel concrete beams made of lipped C-channels with profiled metal decking was experimentally examined. Experimental tests aimed to determine the maximum resistance of the proposed shear connectors; these results were then compared with the predicted values and the values for other shear connectors investigated in other studies. Likewise, the ductility and the strength capacity of the shear connectors were investigated. Twelve push-out test specimens were prepared and tested in accordance with Eurocode 4. It was found that a shear connector's strength capacity considerably depends on its deformation and on the crushing of concrete. The ductile behaviour of all the tested shear connectors satisfied the ductility requirements of Eurocode 4. In this study, it is concluded that the proposed shear connectors were suitable for use in the construction of composite beams, as they were stronger than the standard headed studs and the other available shear connectors; they were also sufficiently strong to perform composite actions. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 298
页数:11
相关论文
共 29 条
[1]  
Allen David., 2006, Stars and Stripes, P1, DOI DOI 10.1061/40889(201)54
[2]  
[Anonymous], 2004, 199411 EN T TELF LTD, DOI [10.1680/dgte4.31517, DOI 10.1680/DGTE4.31517]
[3]  
[Anonymous], 2003, ELECT J STRUCT ENG
[4]  
Bakri A., 2018, ADV SCI LETT, DOI [10.1166/as1.2018.11597, DOI 10.1166/AS1.2018.11597]
[5]   Feasibility of developing composite action between concrete and cold-formed steel beam [J].
Bamaga, S. O. ;
Tahir, M. Md ;
Tan, T. C. ;
Mohammad, S. ;
Yahya, N. ;
Saleh, A. L. ;
Mustaffar, M. ;
Osman, M. H. ;
Rahman, A. B. A. .
JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2013, 20 (12) :3689-3696
[6]  
Bezerra CG, 2016, IEEE CONF EVOL ADAPT, P162
[7]  
E. Standard, 2005, EUR 3 DES STEEL ST 1
[8]  
Easterling W.S., 1993, ENG J
[9]   Tests of composite beams with cold-formed sections [J].
Hanaor, A .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2000, 54 (02) :245-264
[10]  
Hicks Stephen, 2009, Structural Engineering International, V19, P415, DOI 10.2749/101686609789846975