Simultaneous quantification of EVT201, a novel partial positive allosteric GABAA receptor modulator, and its two metabolites in human plasma by UHPLC/MS/MS

被引:7
作者
Zhang, Xianhua [1 ]
Zhou, Congya [1 ]
Zhang, Yuanyuan [1 ]
Zhu, Shuangpeng [2 ]
Cai, Xiaofeng [2 ]
Pan, Chunmiao [2 ]
Wang, Chuanzhen [2 ]
Zhai, Suodi [1 ]
Yang, Li [1 ]
机构
[1] Peking Univ, Third Hosp, Dept Pharm, Beijing 100191, Peoples R China
[2] Zhejiang Jingxin Pharmaceut Co LTD, Shaoxing 312500, Zhejiang, Peoples R China
关键词
UHPLC-MS/MS; EVT201; Ro46-1927; Rol; 8-5528; Human plasma; LC-MS/MS; WHOLE-BLOOD; BENZODIAZEPINES; EVT-201; DRUGS; SERUM;
D O I
10.1016/j.jpba.2018.06.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, accurate and rapid UHPLC-MS/MS method was developed and validated for the simultaneous determination of EVT201 and its two metabolites, Ro46-1927 and Ro18-5528, in human plasma. IN-EVT201 was used as the internal standard (IS). Plasma samples were extracted using ethyl acetate after being alkalized with saturated sodium carbonate solution. Chromatographic separation was carried out on an Acquity BEH C18 column (2.1 x 50 mm, 1.7 mu m) with a gradient mobile phase at a flow-rate of 0.50 mL/min. The analytical run time was 5.5 min. For mass spectrometric detection, multiple reaction monitoring (MRM) was used. The MRM ion transitions were m/z 373.2 -> 58.0 for EVT201, m/z 359.2 -> 316.1 for Ro46-1927, m/z 291.2-4 -> 274.1 for Ro18-5528 and m/z 379.3 -> 64.0 for the IS. The linear range was 0.2-200 ng/mL for each analyte, with a correlation coefficient (r) over 0.9900. The intra/inter-precision was within 7.9% and 4.5% for EVT201, 13.2% and 6.3% for Ro46-1927, 3.7% and 4.1% for Ro 18-5528. For the accuracy, the relative bias of intra-/inter-run was no more than 6.4% and 4.6% for EVT201, 9.4% and 7.9% for Ro46-1927, -6.9% and -7.5% for Ro18-5528. The validated method was successfully applied to the analysis of more than 1500 samples from a Phase I clinical trial. The incurred sample reanalysis (ISR) of 146 samples from the study was evaluated and the results met the acceptance criteria. It indicated that the method could be used for the pharmacokinetic study of EVT201. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:282 / 290
页数:9
相关论文
共 13 条
[1]   Simultaneous determination of Olanzapine and Fluoxetine in human plasma by LC-MS/MS: Its pharmacokinetic application [J].
Bonde, S. L. ;
Bhadane, R. P. ;
Gaikwad, Avinash ;
Gavali, S. R. ;
Katale, D. U. ;
Narendiran, A. S. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 :64-71
[2]  
Boyle J, 2007, SLEEP, V30, pA262
[3]   Development and validation of a fast ionic liquid-based dispersive liquid-liquid microextraction procedure combined with LC-MS/MS analysis for the quantification of benzodiazepines and benzodiazepine-like hypnotics in whole blood [J].
De Boeck, Marieke ;
Missotten, Sophie ;
Dehaen, Wim ;
Tytgat, Jan ;
Cuypers, Eva .
FORENSIC SCIENCE INTERNATIONAL, 2017, 274 :44-54
[4]  
Kemp JA, 2008, SLEEP, V31, pA34
[5]   Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS [J].
Lee, Xiao-Pen ;
Shouji, Yukiko ;
Kumazawa, Takeshi ;
Hasegawa, Chika ;
Fujishiro, Masaya ;
Sato, Junichi ;
Hasegawa, Iwao ;
Sato, Keizo .
LEGAL MEDICINE, 2017, 24 :36-55
[6]   Sensitive UPLC-MS-MS Assay for 21 Benzodiazepine Drugs and Metabolites, Zolpidem and Zopiclone in Serum or Plasma [J].
Marin, Stephanie J. ;
Roberts, Mark ;
Wood, Michelle ;
McMillin, Gwendolyn A. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (07) :472-476
[7]   Detection and quantification of benzodiazepines and Z-drugs in human whole blood, plasma, and serum samples as part of a comprehensive multi-analyte LC-MS/MS approach [J].
Montenarh, Deborah ;
Hopf, Markus ;
Maurer, Hans H. ;
Schmidt, Peter ;
Ewald, Andreas H. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (03) :803-818
[8]   International Classification of Sleep Disorders-Third Edition Highlights and Modifications [J].
Sateia, Michael J. .
CHEST, 2014, 146 (05) :1387-1394
[9]  
Schutte-Rodin S, 2008, J CLIN SLEEP MED, V4, P487
[10]  
Stanley N., 2006, SLEEP, V29