Detectors for the future of X-ray imaging

被引:37
作者
Aslund, M. [1 ]
Fredenberg, E. [2 ]
Telman, M. [1 ]
Danielsson, M. [2 ]
机构
[1] Sectra Mamea AB, S-17141 Solna, Sweden
[2] Royal Inst Technol, Dept Phys, S-10691 Stockholm, Sweden
关键词
COMPUTED-TOMOGRAPHY; SUBTRACTION MAMMOGRAPHY; DIGITAL RADIOGRAPHY; EDGE; PERFORMANCE;
D O I
10.1093/rpd/ncq074
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In recent decades, developments in detectors for X-ray imaging have improved dose efficiency. This has been accomplished with for example, structured scintillators such as columnar CsI, or with direct detectors where the X rays are converted to electric charge carriers in a semiconductor. Scattered radiation remains a major noise source, and fairly inefficient anti-scatter grids are still a gold standard. Hence, any future development should include improved scatter rejection. In recent years, photon-counting detectors have generated significant interest by several companies as well as academic research groups. This method eliminates electronic noise, which is an advantage in low-dose applications. Moreover, energy-sensitive photon-counting detectors allow for further improvements by optimising the signal-to-quantum-noise ratio, anatomical background subtraction or quantitative analysis of object constituents. This paper reviews state-of-the-art photon-counting detectors, scatter control and their application in diagnostic X-ray medical imaging. In particular, spectral imaging with photon-counting detectors, pitfalls such as charge sharing and high rates and various proposals for mitigation are discussed.
引用
收藏
页码:327 / 333
页数:7
相关论文
共 35 条
[1]  
Aichinger H., 2004, Radiation exposure and image quality in x-ray diagnostic radiology: physical principles and clinical applications
[2]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[3]   Scatter rejection in multislit digital mammography [J].
Åslund, M ;
Cederström, B ;
Lundqvist, M ;
Danielsson, M .
MEDICAL PHYSICS, 2006, 33 (04) :933-940
[4]   Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors [J].
Aslund, Magnus ;
Cederstrom, Bjorn ;
Lundqvist, Mats ;
Danielsson, Mats .
MEDICAL PHYSICS, 2007, 34 (06) :1918-1925
[5]   Optimization of operating conditions in photon counting multi-slit mammography based on Si-strip detectors [J].
Aslund, Magnus ;
Cederstrom, Bjorn ;
Lundqvist, Mats ;
Danielsson, Mats .
Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 :A1420-A1420
[6]   Contrast cancellation technique applied to digital x-ray imaging using silicon strip detectors [J].
Avila, C ;
Lopez, J ;
Sanabria, JC ;
Baldazzi, G ;
Bollini, D ;
Gombia, M ;
Cabal, AE ;
Ceballos, C ;
Garcia, AD ;
Gambaccini, M ;
Taibi, A ;
Sarnelli, A ;
Tuffanelli, A ;
Giubellino, P ;
Marzari-Chiesa, A ;
Prino, F ;
Tomassi, E ;
Grybos, P ;
Idzik, M ;
Swientek, K ;
Wiacek, P ;
Montaño, LM ;
Ramello, L ;
Sitta, M .
MEDICAL PHYSICS, 2005, 32 (12) :3755-3766
[7]   Edge on silicon microstrip detectors for medical imaging [J].
Bergamaschi, A ;
Arfelli, F ;
Dreossi, D ;
Longo, R ;
Olivo, A ;
Pani, S ;
Rigon, L ;
Castelli, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3) :199-204
[8]  
BORNEFALK H, 2006, P SPIE PHYS MED IMAG, V6142
[9]   Single-shot dual-energy subtraction mammography with electronic spectrum splitting: Feasibility [J].
Bornefalk, Hans ;
Lewin, John M. ;
Danielsson, Mats ;
Lundqvist, Mats .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (02) :275-278
[10]   Detective quantum efficiency dependence on x-ray energy weighting in mammography [J].
Cahn, RN ;
Cederström, B ;
Danielsson, M ;
Hall, A ;
Lundqvist, M ;
Nygren, D .
MEDICAL PHYSICS, 1999, 26 (12) :2680-2683