A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system:: Validation in a heterogeneous phantom

被引:76
作者
Gellermann, J
Wlodarczyk, W
Ganter, H
Nadobny, J
Fähling, H
Seebass, M
Felix, R
Wust, P
机构
[1] Charite, Sch Med, Dept Radiat Med, D-13353 Berlin, Germany
[2] Indeed Visual Concepts, Berlin, Germany
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 61卷 / 01期
关键词
magnetic resonance; thermography; regional hyperthermia; proton frequency shift method; phantom; annular phased array;
D O I
10.1016/j.ijrobp.2004.05.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study investigates the feasibility and accuracy of noninvasive magnetic resonance (MR) monitoring for a-system that includes a multiantenna applicator for part-body hyperthermia (SIGMA-Eye applicator, BSD-2000/3D) and a 1.5 Testa MR tomograph (Siemens Magnetom Symphony). Methods: A careful electrical decoupling enabled simultaneous operation of both systems, the hyperthermia system (100 MHz, up to 1600 W) and the MR tomograph (63.9 MHz). We used the phase data sets of a gradient echo sequence (long echo time TE = 20 ms) according to the proton frequency shift (PFS) method to determine MR temperature changes. Data postprocessing and visualization was conducted in the software platform AMIRA-HyperPlan. Heating was evaluated in an elliptical Lucite cylinder of 50 cm length filled with tissue-equivalent agarose and a skeleton made from low-dielectric material to simulate the heterogeneity of a real patient. Multiple catheters were included longitudinally for direct thermometry (using Bowman high-impedance thermistors). The phantom was positioned in the 24-antenna applicator SIGMA-Eye employing the integrated water bolus (filled with deionized water) both for coupling the radiated power into the lossy medium and to enable a correction procedure based on direct temperature measurements. Results: In eight phantom experiments we monitored the heating in the applicator not only by repetitive acquisition of three-dimensional MR datasets, but also by measuring temperature-time curves directly at selected spatial positions. For the correction, we specified regions in the bolus. Direct bolus temperatures at fixed positions were taken to aim at best possible agreement between MR temperatures and these direct temperature-time curves. Then we compared additional direct temperature-position scans (thermal maps) for each experiment with the MR temperatures along these probes, which agreed satisfactorily (averaged accuracy of +/- 0.4-0.5degreesC). The deviations decreased with decreasing observation time, temperature increase, and thermal load to the surroundings (corresponding to bolus heating)-estimating a resolution of, at best, +/- 0.2-0.3degreesC. The acquired MR temperature distributions give also insight into limitations and control possibilities of regional hyperthermia (annular phased array technology) for various tumor sites. Conclusions: On-line MR monitoring of regional hyperthermia by using the PFS method is feasible in a phantom setup and can be further developed for clinical applications. (C) 2005 Elsevier Inc.
引用
收藏
页码:267 / 277
页数:11
相关论文
共 12 条
  • [1] Estimation the tumor temperature in magnetic nanoparticle hyperthermia by infrared thermography: Phantom and numerical studies
    Ma, Ming
    Zhang, Yu
    Gu, Ning
    JOURNAL OF THERMAL BIOLOGY, 2018, 76 : 89 - 94
  • [2] Non-invasive thermography of laser-induced hyperthermia using magnetic resonance
    Maswadi, SM
    Glickman, RD
    Dodd, SJ
    Gao, JH
    LASER INTERACTION WITH TISSUE AND CELLS XV, 2004, 5319 : 301 - 312
  • [3] Biomimetic Phantom for the Validation of Diffusion Magnetic Resonance Imaging
    Hubbard, Penny L.
    Zhou, Feng-Lei
    Eichhorn, Stephen J.
    Parker, Geoffrey J. M.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 299 - 305
  • [4] A standard system phantom for magnetic resonance imaging
    Stupic, Karl F.
    Ainslie, Maureen
    Boss, Michael A.
    Charles, Cecil
    Dienstfrey, Andrew M.
    Evelhoch, Jeffrey L.
    Finn, Paul
    Gimbutas, Zydrunas
    Gunter, Jeffrey L.
    Hill, Derek L. G.
    Jack, Clifford R.
    Jackson, Edward F.
    Karaulanov, Todor
    Keenan, Kathryn E.
    Liu, Guoying
    Martin, Michele N.
    Prasad, Pottumarthi, V
    Rentz, Nikki S.
    Yuan, Chun
    Russek, Stephen E.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1194 - 1211
  • [5] Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
    Keenan, Kathryn E.
    Ainslie, Maureen
    Barker, Alex J.
    Boss, Michael A.
    Cecil, Kim M.
    Charles, Cecil
    Chenevert, Thomas L.
    Clarke, Larry
    Evelhoch, Jeffrey L.
    Finn, Paul
    Gembris, Daniel
    Gunter, Jeffrey L.
    Hill, Derek L. G.
    Jack, Clifford R., Jr.
    Jackson, Edward F.
    Liu, Guoying
    Russek, Stephen E.
    Sharma, Samir D.
    Steckner, Michael
    Stupic, Karl F.
    Trzasko, Joshua D.
    Yuan, Chun
    Zheng, Jie
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 48 - 61
  • [6] An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System
    Shurche, Sadegh
    Sooteh, Mohammad Yousefi
    Iranian Journal of Medical Physics, 2024, 21 (01) : 53 - 63
  • [7] Magnetic Resonance-Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation
    Chu, William
    Staruch, Robert M.
    Pichardo, Samuel
    Tillander, Matti
    Kohler, Max O.
    Huang, Yuexi
    Ylihautala, Mika
    McGuffin, Merrylee
    Czarnota, Gregory
    Hynynen, Kullervo
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (04): : 1259 - 1267
  • [8] A new thermography-based approach to early detection of cancer utilizing magnetic nanoparticles theory simulation and in vitro validation
    Levy, Arie
    Dayan, Abraham
    Ben-David, Moshe
    Gannot, Israel
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2010, 6 (06) : 786 - 796
  • [9] Use of a virtual phantom to assess the capability of a treatment planning system to perform magnetic resonance image distortion correction
    Moreno, Rogelio Manuel Diaz
    Nunez, Gonzalo
    Venencia, C. Daniel
    Isoardi, Roberto A.
    Almada, Maria Jose
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2025, : 317 - 327
  • [10] Development of a novel task-based functional magnetic resonance imaging phantom based on a bubble-compression approach
    Yamashiro, Akihiro
    Saito, Takaaki
    Miyati, Tosiaki
    MEDICAL PHYSICS, 2022, 49 (06) : 3717 - 3728