Dosimetry of high dose skeletal targeted radiotherapy (STR) with 166Ho-DOTMP

被引:37
作者
Breitz, H
Wendt, R
Stabin, M
Bouchet, L
Wessels, B
机构
[1] NEORX Corp, Seattle, WA 98119 USA
[2] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
[3] Vanderbilt Univ, Nashville, TN USA
[4] Univ Florida, Gainesville, FL USA
[5] Case Western Reserve Univ, Cleveland, OH 44106 USA
关键词
Ho-166-DOTMP; dosimetry; skeletal targeted radiotherapy;
D O I
10.1089/108497803765036391
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A study was undertaken to determine the maximum tolerated dose of Ho-166-DOTMP that could be administered safely, without negatively impacting marrow re-engraftment, in patients with multiple myeloma treated with melphalan prior to transplant. Ho-166 DOTMP is a tetraphosphonate that localizes rapidly to bone surface. The Ho-166 physical half-life is 26.8 hr and the maximum beta energy is 1.8 MeV. Standard dosimetry models were adapted for radiation absorbed dose estimates using data obtained from whole body counting of the low abundance photons emitted by Ho-166. Eighty-three patients received high dose Ho-166-DOTMP followed by melphalan and transplant of peripheral blood stem cells. Twenty-five patients also received 8 Gy total body radiation (TBI). Dosages administered ranged from 460 to 4476 MCi Ho-166-DOTMP. Marrow dose was derived using the assumption that all radioactivity not excreted by 20 hours was localized to the bone surfaces, and applying the Eckerman bone and marrow dose model to the calculated bone residence times. The dosimetry of the urinary bladder and kidneys was important because of the rapid excretion of the non-targeted radioactivity via the urinary pathway. The dynamic bladder model was used for bladder wall surface dose, and the ICRP 53 kinetic model was used to model kidney kinetics with an additional blood component included. Marrow doses ranged from 13 to 59 Gy and successful hematapoietic recovery occurred. Bladder doses ranged from 4.7 to 157 Gy. Hemorrhagic cystitis occurred in some patients who received more than 40 Gy to the bladder wall surface. Bladder irrigation was successful in protecting patients from bladder toxicity. Kidney doses ranged from 0.5-7.9 Gy. Kidney toxicity, in the form of thrombotic microangiopathy with renal dysfunction was observed, with the severity being related to Ho-166-DOTMP radiation dose and probably the dose rate as well. In a future trial, kidney dosimetry will be assessed using early serial gamma camera imaging and modifications will be implemented to reduce renal toxicity.
引用
收藏
页码:225 / 230
页数:6
相关论文
共 4 条
  • [1] 166Ho-DOTMP radiation-absorbed dose estimation for skeletal targeted radiotherapy
    Breitz, Hazel B.
    Wendt, Richard E.
    Stabin, Michael S.
    Shen, Sui
    Erwin, William D.
    Rajendran, Joseph G.
    Eary, Janet F.
    Durack, Lawrence
    Delpassand, Ebrahim
    Martin, William
    Meredith, Ruby F.
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (03) : 534 - 542
  • [2] High-dose 166Ho-DOTMP in myeloablative treatment of multiple myeloma:: Pharmacokinetics, biodistribution, and absorbed dose estimation
    Rajendran, JG
    Eary, JF
    Bensinger, W
    Durack, LD
    Vernon, C
    Fritzberg, A
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (10) : 1383 - 1390
  • [3] Response of diamond detectors in ultra-high dose-per-pulse electron beams for dosimetry at FLASH radiotherapy
    Kranzer, R.
    Schueller, A.
    Bourgouin, A.
    Hackel, T.
    Poppinga, D.
    Lapp, M.
    Looe, H. K.
    Poppe, B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (07)
  • [4] Time-resolved dosimetry of pulsed electron beams in very high dose-rate, FLASH irradiation for radiotherapy preclinical studies
    Favaudon, Vincent
    Lentz, Jean-Michel
    Heinrich, Sophie
    Patriarca, Annalisa
    de Marzi, Ludovic
    Fouillade, Charles
    Dutreix, Marie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 944