Concordance of Lateral Flow and Skin Prick Tests in the Assessment of Allergen Sensitisation in the Epidemiological Field in Children

被引:2
作者
Sanchez-Bahillo, Maria [2 ,3 ,4 ]
Garcia-Marcos, Luis [1 ,3 ,4 ,5 ]
Elena Martinez-Torres, Antonia [3 ,4 ]
Perez-Fernandez, Virginia [1 ]
Sanchez-Solis, Manuel [1 ,3 ,4 ]
机构
[1] Univ Murcia, Dept Paediat, ES-30120 Murcia, Spain
[2] Hlth Educ & Res Fdn, Murcia Reg FFIS, Murcia, Spain
[3] Arrixaca Univ Childrens Hosp Murcia, Paediat Pulmonol Unit, Murcia, Spain
[4] Arrixaca Univ Childrens Hosp Murcia, Allergy Unit, Murcia, Spain
[5] CIBER Epidemiol & Publ Hlth, CIBERESP, Murcia, Spain
关键词
Atopy; Children; Diagnosis; Epidemiology; ImmunoCAP (TM) Rapid; Lateral flow test; Sensitisation; Skin prick test; CAP SYSTEM; IGE; PERFORMANCE; IMMUNOCAP; ASSAYS;
D O I
10.1159/000288291
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: A new lateral flow test (LFT) for office use provides information about sensitisation to common allergens. Concordance between LFT and skin-prick test (SPT) has not been assessed in epidemiological studies. The aim of this study is to determine LFT-SPT concordance in this field. Methods: Plasma samples (n = 270) from children aged 9-12 years previously SPT tested were used for the analysis. We selected 180 samples from children SPT positive to any of the 6 allergens which were common to SPT and LFT (cat, birch, timothy-grass, olive, pellitory and Dermatophagoides pteronyssinus), and 90 samples from children SPT negative. The intensity of the LFT colour line which indicates a positive reaction was rated from 0 to 4. Results: Only results on cat, olive and D. pteronyssinus were analysed, as only these had an acceptable number of individuals. When atopy was defined as at least 1 wheal with a mean diameter 6 3 mm, agreement was excellent (Cohen's kappa = 0.81) when a lightly visible line was considered positive in the LFT, and dropped substantially (Cohen's kappa = 0.68) when this value of LFT was considered negative. The correlation between the SPT wheal diameter and the intensity of the LFT line was 0.71 for cat, 0.81 for olive and 0.78 for D. pteronyssinus. Conclusions: As compared to SPT, LFT is a reliable method to screen for sensitisation to cat dander, olive pollen and D. pteronyssinus in the epidemiological field among schoolchildren. There is a good correlation between the SPT wheal diameter and the intensity of the LFT line. Copyright (C) 2010 S. Karger AG, Basel
引用
收藏
页码:378 / 383
页数:6
相关论文
共 14 条
[1]  
ALONSO R, 1995, J INVEST ALLERG CLIN, V5, P156
[2]   Accuracy of ImmunoCAP® Rapid in the diagnosis of allergic sensitization in children between 1 and 14 years with recurrent wheezing: The IReNE study [J].
Diaz-Vazquez, Carlos ;
Jose Torregrosa-Bertet, Maria ;
Carvajal-Uruena, Ignacio ;
Cano-Garcinuno, Alfredo ;
Fos-Escriva, Emili ;
Garcia-Gallego, Amparo ;
Lopez-Cacho, Ferran ;
Carmen Monzon-Fueyo, Ma ;
Perez-Porcuna, Xavier M. ;
Luisa Ridao-Redondo, Ma .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2009, 20 (06) :601-609
[3]   EVALUATION OF A CAPSULATED HYDROPHILIC CARRIER POLYMER (THE IMMUNOCAP) FOR MEASUREMENT OF SPECIFIC IGE ANTIBODIES [J].
EWAN, PW ;
COOTE, D .
ALLERGY, 1990, 45 (01) :22-29
[4]   A different pattern of risk factors for atopic and non-atopic wheezing in 9-12-year-old children [J].
García-Marcos, L ;
Castro-Rodríguez, JA ;
Suarez-Varela, MM ;
Garrido, JB ;
Hernandez, GG ;
Gimeno, AM ;
González, AL ;
Ruiz, TR ;
Torres, AM .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2005, 16 (06) :471-477
[5]   Phadiatop™ compared to skin-prick test as a tool for diagnosing atopy in epidemiological studies in schoolchildren [J].
Garcia-Marcos, Luis ;
Sanchez-Solis, Manuel ;
Martinez-Torres, Antonia E. ;
Moreno, Jose M. Lucas ;
Sastre, Vicente Hernando .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2007, 18 (03) :240-244
[6]  
Gleeson M, 1996, CLIN EXP ALLERGY, V26, P697, DOI 10.1111/j.1365-2222.1996.tb00596.x
[7]  
KAM KL, 1994, ANN ALLERGY, V73, P329
[8]   COMPARISON BETWEEN MAGIC LITE(R)-SYSTEM AND CAP(R)-SYSTEM - 2 AUTOMATED SPECIFIC IGE ANTIBODY-ASSAYS [J].
KLEINETEBBE, J ;
EICKHOLT, M ;
GATJEN, M ;
BRUNNEE, T ;
OCONNOR, A ;
KUNKEL, G .
CLINICAL AND EXPERIMENTAL ALLERGY, 1992, 22 (04) :475-484
[9]  
Nepper-Christensen S, 2003, ALLERGY ASTHMA PROC, V24, P253
[10]   Performance characteristics of a new automated enzyme immunoassay for the measurement of allergen-specific IgE - Summary of the probability outcomes comparing results of allergen skin testing to results obtained with the HYTEC system and CAP system [J].
Nolte, H ;
DuBuske, LM .
ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 1997, 79 (01) :27-34