Treatment of comminuted intraarticular distal femur fractures with limited internal and external tensioned wire fixation

被引:49
|
作者
Hutson, JJ [1 ]
Zych, GA [1 ]
机构
[1] Univ Miami, Sch Med, Dept Orthoped, Miami, FL USA
关键词
intraarticular femur fracture; limited internal fixation; hybrid circular wire; Ilizarov fixator;
D O I
10.1097/00005131-200008000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Evaluate the treatment of C3 distal femur fractures with limited internal fixation and tensioned wire circular external fixation. Design: Prospective cohort study, from June 1992 to July 1996. Setting: Urban Level 1 trauma center. Patients: Sixteen fractures in sixteen patients: nine male, seven female. Fractures: C3.1 one, C3.2 one, C3.3 fourteen. Twelve fractures were open: one GI, seven Oil, two GIIIA, one GIIIB, and one GIIIC. Intervention: Fractures were treated with limited open fixation of the condylar joint surface and tensioned wire circular external fixation of the metaphysis and shaft for axial alignment. Three fractures had acute autologous bone grafts. Main Outcome Measurements: The patient's extremity function was evaluated by the authors by using the Sanders et al. Distal Femur Functional Evaluation. Results: Sixteen of sixteen fractures healed. Two patients had delayed bone grafting for delayed union. Average frame time was twenty-five weeks. Average range of motion was 0 to 92 degrees. Five patients had less than 90 degrees of flexion. Five patients required a quadricepsplasty. Average follow-up was thirty-five months. One patient developed a pintract infection. One patient developed septic arthritis, and another developed osteomyelitis. The average Sanders et al, Function knee score was twenty-eight, with a maximum possible score of forty. Conclusions: C3 fractures of the distal femur are associated with severe soft tissue injuries and bone loss. Loss of function appears to be directly related to these factors. Treatment with limited internal fixation and tensioned wire external fixation has equivalent results to other methods but has a higher incidence of infection and complications. Joint motion is retarded by binding of the soft tissues with fixation wires and pins. The technique is recommended only for salvage of severely comminuted and open fractures of the distal femur with extensive soft tissue injury. Distal femur fractures with moderate comminution and soft tissue injury should be treated with alternate methods.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 9 条
  • [1] Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation
    Catagni, Maurizio A.
    Ottaviani, Giulia
    Maggioni, Massimiliano
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (05): : 1043 - 1053
  • [2] Study on the application of external fixator and limited internal fixation in combined treatment of limbs fractures
    Yang, Yong
    Ma, Yonghui
    Lu, Ning
    Xu, Dong
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (15): : 6773 - 6776
  • [3] Treatment of open tibial diaphyseal fractures by external fixation combined with limited internal fixation versus simple external fixation: a retrospective cohort study
    Zi-Chen Hao
    Yan Xia
    De-Meng Xia
    Yun-Tong Zhang
    Shuo-Gui Xu
    BMC Musculoskeletal Disorders, 20
  • [4] Treatment of open tibial diaphyseal fractures by external fixation combined with limited internal fixation versus simple external fixation: a retrospective cohort study
    Hao, Zi-Chen
    Xia, Yan
    Xia, De-Meng
    Zhang, Yun-Tong
    Xu, Shuo-Gui
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [5] LIMITED INTERNAL-FIXATION OF THE TIBIA WITH EXTERNAL FIXATION - AN IN-VIVO CANINE STUDY
    OSTRUM, RF
    LITSKY, AS
    ANSON, LW
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (01) : 50 - 53
  • [6] Post-Operative Outcomes of Circular External Fixation in the Definitive Treatment of Tibial Plafond Fractures: A Systematic Review
    Legg, Peter, I
    Malik-Tabassum, Khalid
    Ibrahim, Yasser H.
    Dhinsa, Baljinder S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
  • [7] RETRACTED: A randomised prospective study of two different combined internal and external fixation techniques for distal tibia shaft fractures (Retracted article. See vol. 46, pg. 1700, 2015)
    Sun, Liao-Jun
    Yu, Xian-Bin
    Dai, Cheng-Qian
    Hu, Wei
    Guo, Xiao-Shan
    Chen, Hua
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12): : 1990 - 1995
  • [8] Comparative Outcome of Hybrid External Fixator Versus Primary Ilizarov Fixator in the Treatment of Open Distal Tibia Extra-Articular Fractures
    Borah, Pranab Jyoti
    Patowary, Chandan
    Das, Abhijit
    Shirdinayak, Tirupati Shivanand
    Roy, Jyoti Prakash
    Kumar, Sourabh
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (11) : 2006 - 2012
  • [9] Comparative Outcome of Hybrid External Fixator Versus Primary Ilizarov Fixator in the Treatment of Open Distal Tibia Extra-Articular Fractures
    Pranab Jyoti Borah
    Chandan Patowary
    Abhijit Das
    Tirupati Shivanand Shirdinayak
    Jyoti Prakash Roy
    Sourabh Kumar
    Indian Journal of Orthopaedics, 2022, 56 : 2006 - 2012