共 71 条
An Experimental Study on the Validity and Reliability of a Smartphone Application to Acquire Temporal Variables during the Single Sit-to-Stand Test with Older Adults
被引:15
作者:
Marques, Diogo Luis
[1
]
Neiva, Henrique Pereira
[1
,2
]
Pires, Ivan Miguel
[3
,4
,5
]
Zdravevski, Eftim
[6
]
Mihajlov, Martin
[7
]
Garcia, Nuno M.
[3
]
Ruiz-Cardenas, Juan Diego
[8
]
Marinho, Daniel Almeida
[1
,2
]
Marques, Mario Cardoso
[1
,2
]
机构:
[1] Univ Beira Interior, Dept Sport Sci, P-6201001 Covilha, Portugal
[2] CIDESD, Hlth Sci & Human Dev, Res Ctr Sports Sci, P-6201001 Covilha, Portugal
[3] Univ Beira Interior, Inst Telecomunicacoes, P-6200001 Covilha, Portugal
[4] Polytech Inst Viseu, Comp Sci Dept, P-3504510 Viseu, Portugal
[5] Polytech Inst Viseu, Sch Hlth, Hlth Sci Res Unit Nursing, P-3504510 Viseu, Portugal
[6] Univ Ss Cyril & Methodius, Fac Comp Sci & Engn, Skopje 1000, North Macedonia
[7] Jozef Stefan Inst, Lab Open Syst & Networks, Ljubljana 1000, Slovenia
[8] Catholic Univ Murcia, Physiotherapy Dept, Fac Hlth Sci, Murcia 30107, Spain
来源:
关键词:
mobile application;
accelerometer sensor;
stand-up time;
total time;
aging;
5 TIMES SIT;
CORRELATION-COEFFICIENTS;
PERFORMANCE TESTS;
LEG POWER;
STRENGTH;
MOVEMENT;
BALANCE;
HEALTH;
SENSOR;
FALLS;
D O I:
10.3390/s21062050
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Smartphone sensors have often been proposed as pervasive measurement systems to assess mobility in older adults due to their ease of use and low-cost. This study analyzes a smartphone-based application's validity and reliability to quantify temporal variables during the single sit-to-stand test with institutionalized older adults. Forty older adults (20 women and 20 men; 78.9 +/- 8.6 years) volunteered to participate in this study. All participants performed the single sit-to-stand test. Each sit-to-stand repetition was performed after an acoustic signal was emitted by the smartphone app. All data were acquired simultaneously with a smartphone and a digital video camera. The measured temporal variables were stand-up time and total time. The relative reliability and systematic bias inter-device were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plots. In contrast, absolute reliability was assessed using the standard error of measurement and coefficient of variation (CV). Inter-device concurrent validity was assessed through correlation analysis. The absolute percent error (APE) and the accuracy were also calculated. The results showed excellent reliability (ICC = 0.92-0.97; CV = 1.85-3.03) and very strong relationships inter-devices for the stand-up time (r = 0.94) and the total time (r = 0.98). The APE was lower than 6%, and the accuracy was higher than 94%. Based on our data, the findings suggest that the smartphone application is valid and reliable to collect the stand-up time and total time during the single sit-to-stand test with older adults.
引用
收藏
页码:1 / 15
页数:15
相关论文