An Experimental Study on the Validity and Reliability of a Smartphone Application to Acquire Temporal Variables during the Single Sit-to-Stand Test with Older Adults

被引:15
作者
Marques, Diogo Luis [1 ]
Neiva, Henrique Pereira [1 ,2 ]
Pires, Ivan Miguel [3 ,4 ,5 ]
Zdravevski, Eftim [6 ]
Mihajlov, Martin [7 ]
Garcia, Nuno M. [3 ]
Ruiz-Cardenas, Juan Diego [8 ]
Marinho, Daniel Almeida [1 ,2 ]
Marques, Mario Cardoso [1 ,2 ]
机构
[1] Univ Beira Interior, Dept Sport Sci, P-6201001 Covilha, Portugal
[2] CIDESD, Hlth Sci & Human Dev, Res Ctr Sports Sci, P-6201001 Covilha, Portugal
[3] Univ Beira Interior, Inst Telecomunicacoes, P-6200001 Covilha, Portugal
[4] Polytech Inst Viseu, Comp Sci Dept, P-3504510 Viseu, Portugal
[5] Polytech Inst Viseu, Sch Hlth, Hlth Sci Res Unit Nursing, P-3504510 Viseu, Portugal
[6] Univ Ss Cyril & Methodius, Fac Comp Sci & Engn, Skopje 1000, North Macedonia
[7] Jozef Stefan Inst, Lab Open Syst & Networks, Ljubljana 1000, Slovenia
[8] Catholic Univ Murcia, Physiotherapy Dept, Fac Hlth Sci, Murcia 30107, Spain
关键词
mobile application; accelerometer sensor; stand-up time; total time; aging; 5 TIMES SIT; CORRELATION-COEFFICIENTS; PERFORMANCE TESTS; LEG POWER; STRENGTH; MOVEMENT; BALANCE; HEALTH; SENSOR; FALLS;
D O I
10.3390/s21062050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Smartphone sensors have often been proposed as pervasive measurement systems to assess mobility in older adults due to their ease of use and low-cost. This study analyzes a smartphone-based application's validity and reliability to quantify temporal variables during the single sit-to-stand test with institutionalized older adults. Forty older adults (20 women and 20 men; 78.9 +/- 8.6 years) volunteered to participate in this study. All participants performed the single sit-to-stand test. Each sit-to-stand repetition was performed after an acoustic signal was emitted by the smartphone app. All data were acquired simultaneously with a smartphone and a digital video camera. The measured temporal variables were stand-up time and total time. The relative reliability and systematic bias inter-device were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plots. In contrast, absolute reliability was assessed using the standard error of measurement and coefficient of variation (CV). Inter-device concurrent validity was assessed through correlation analysis. The absolute percent error (APE) and the accuracy were also calculated. The results showed excellent reliability (ICC = 0.92-0.97; CV = 1.85-3.03) and very strong relationships inter-devices for the stand-up time (r = 0.94) and the total time (r = 0.98). The APE was lower than 6%, and the accuracy was higher than 94%. Based on our data, the findings suggest that the smartphone application is valid and reliable to collect the stand-up time and total time during the single sit-to-stand test with older adults.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 71 条
[51]   Accuracy and concurrent validity of a sensor-based analysis of sit-to-stand movements in older adults [J].
Regterschot, G. Ruben H. ;
Zhang, Wei ;
Baldus, Heribert ;
Stevens, Martin ;
Zijlstra, Wiebren .
GAIT & POSTURE, 2016, 45 :198-203
[52]   Sensitivity of sensor-based sit-to-stand peak power to the effects of training leg strength, leg power and balance in older adults [J].
Regterschot, G. Ruben H. ;
Folkersma, Marjanne ;
Zhang, Wei ;
Baldus, Heribert ;
Stevens, Martin ;
Zijlstra, Wiebren .
GAIT & POSTURE, 2014, 39 (01) :303-307
[53]   Reliability and validity of three strength measures obtained from community-dwelling elderly persons [J].
Schaubert, KL ;
Bohannon, RW .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2005, 19 (03) :717-720
[54]   Correlation Coefficients: Appropriate Use and Interpretation [J].
Schober, Patrick ;
Boer, Christa ;
Schwarte, Lothar A. .
ANESTHESIA AND ANALGESIA, 2018, 126 (05) :1763-1768
[55]  
Sousa P.S., 2015, SPRINGER SERIES BION, V5, P265
[56]   Identifying balance impairments in people with Parkinson's disease using video and wearable sensors [J].
Stack, Emma ;
Agarwal, Veena ;
King, Rachel ;
Burnett, Malcolm ;
Tahavori, Fatemeh ;
Janko, Balazs ;
Harwin, William ;
Ashburn, Ann ;
Kunkel, Dorit .
GAIT & POSTURE, 2018, 62 :321-326
[57]   The use of functional performance tests by primary health-care providers to determine walking ability with and without awalking device in community-dwelling elderly [J].
Suwannarat, Patcharawan ;
Kaewsanmung, Supapon ;
Thaweewannakij, Thiwabhorn ;
Amatachaya, Sugalya .
PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (01) :64-72
[58]   The comparative ability of eight functional mobility tests for predicting falls in community-dwelling older people [J].
Tiedemann, Anne ;
Shimada, Hiroyuki ;
Sherrington, Catherine ;
Murray, Susan ;
Lord, Stephen .
AGE AND AGEING, 2008, 37 (04) :430-435
[59]   Automated approach for quantifying the repeated sit-to-stand using one body fixed sensor in young and older adults [J].
Van Lummel, R. C. ;
Ainsworth, E. ;
Lindemann, U. ;
Zijlstra, W. ;
Chiari, L. ;
Van Campen, P. ;
Hausdorff, J. M. .
GAIT & POSTURE, 2013, 38 (01) :153-156
[60]   The Instrumented Sit-to-Stand Test (iSTS) Has Greater Clinical Relevance than the Manually Recorded Sit-to-Stand Test in Older Adults [J].
van Lummel, Rob C. ;
Walgaard, Stefan ;
Maier, Andrea B. ;
Ainsworth, Erik ;
Beek, Peter J. ;
van Dieen, Jaap H. .
PLOS ONE, 2016, 11 (07)