Comparison of Diffusion Kurtosis Imaging and Amide Proton Transfer Imaging in the Diagnosis and Risk Assessment of Prostate Cancer

被引:21
作者
Yin, Huijia [1 ]
Wang, Dongdong [2 ]
Yan, Ruifang [1 ]
Jin, Xingxing [1 ]
Hu, Ying [1 ]
Zhai, Zhansheng [1 ]
Duan, Jinhui [1 ]
Zhang, Jian [1 ]
Wang, Kaiyu [3 ]
Han, Dongming [1 ]
机构
[1] Xinxiang Med Univ, Affiliated Hosp 1, Dept MR, Weihui, Peoples R China
[2] Peoples Hosp Zhengzhou, Dept Radiol, Zhengzhou, Peoples R China
[3] GE Healthcare, MR Res China, Beijing, Peoples R China
关键词
diffusion kurtosis imaging; amide proton transfer; prostate cancer; Gleason score; benign prostatic hyperplasia;
D O I
10.3389/fonc.2021.640906
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives This study aims to evaluate and compare the diagnostic value of DKI and APT in prostate cancer (PCa), and their correlation with Gleason Score (GS). Materials and Methods DKI and APT imaging of 49 patients with PCa and 51 patients with benign prostatic hyperplasia (BPH) were collected and analyzed, respectively. According to the GS, the patients with PCa were divided into high-risk, intermediate-risk and low-risk groups. The mean kurtosis (MK), mean diffusion (MD) and magnetization transfer ratio asymmetry (MTRasym, 3.5 ppm) values among PCa, BPH, and different GS groups of PCa were compared and analyzed respectively. The diagnostic accuracy of each parameter was evaluated by using the receiver operating characteristic (ROC) curve. The correlation between each parameter and GS was analyzed by using Spearman's rank correlation. Results The MK and MTRasym (3.5 ppm) values were significantly higher in PCa group than in BPH group, while the MD value was significantly lower than in BPH group. The differences of MK/MD/MTRasym (3.5 ppm) between any two of the low-risk, intermediate-risk, and high-risk groups were all statistically significant (p <0.05). The MK value showed the highest diagnostic accuracy in differentiating PCa and BPH, BPH and low-risk, low-risk and intermediate-risk, intermediate-risk and high-risk (AUC = 0.965, 0.882, 0.839, 0.836). The MK/MD/MTRasym (3.ppm) values showed good and moderate correlation with GS (r = 0.844, -0.811, 0.640, p <0.05), respectively. Conclusion DKI and APT imaging are valuable in the diagnosis of PCa and demonstrate strong correlation with GS, which has great significance in the risk assessment of PCa.
引用
收藏
页数:10
相关论文
共 43 条
[1]   Interobserver Variability of Selective Region-of-Interest Measurement Protocols for Quantitative Diffusion Weighted Imaging in Soft Tissue Masses: Comparison with Whole Tumor Volume Measurements [J].
Ahlawat, Shivani ;
Khandheria, Paras ;
Del Grande, Filippo ;
Morelli, John ;
Subhawong, Ty K. ;
Demehri, Shadpour ;
Fayad, Laura M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (02) :446-454
[2]   Diagnostic evaluation of magnetization transfer and diffusion kurtosis imaging for prostate cancer detection in a re-biopsy population [J].
Barrett, Tristan ;
McLean, Mary ;
Priest, Andrew N. ;
Lawrence, Edward M. ;
Patterson, Andrew J. ;
Koo, Brendan C. ;
Patterson, Ilse ;
Warren, Anne Y. ;
Doble, Andrew ;
Gnanapragasam, Vincent J. ;
Kastner, Christof ;
Gallagher, Ferdia A. .
EUROPEAN RADIOLOGY, 2018, 28 (08) :3141-3150
[3]   Apparent diffusion coefficient ratio correlates significantly with prostate cancer gleason score at final pathology [J].
Boesen, Lars ;
Chabanova, Elizaveta ;
Logager, Vibeke ;
Balslev, Ingegerd ;
Thomsen, Henrik S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) :446-453
[4]  
Bostwick D G, 1999, Semin Urol Oncol, V17, P222
[5]   An overview of current and emerging diagnostic, staging and prognostic markers for prostate cancer [J].
Broenimann, Stephan ;
Pradere, Benjamin ;
Karakiewicz, Pierre ;
Abufaraj, Mohammad ;
Briganti, Alberto ;
Shariat, Shahrokh F. .
EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2020, 20 (08) :841-850
[6]   A semi-automated method for rapid detection of ripple events on interictal voltage discharges in the scalp electroencephalogram [J].
Chu, Catherine J. ;
Chan, Arthur ;
Song, Dan ;
Staley, Kevin J. ;
Stufflebeam, Steven M. ;
Kramer, Mark A. .
JOURNAL OF NEUROSCIENCE METHODS, 2017, 277 :46-55
[7]   Apparent Diffusion Coefficient Value and Ratio as Noninvasive Potential Biomarkers to Predict Prostate Cancer Grading: Comparison With Prostate Biopsy and Radical Prostatectomy Specimen [J].
De Cobelli, Francesco ;
Ravelli, Silvia ;
Esposito, Antonio ;
Giganti, Francesco ;
Gallina, Andrea ;
Montorsi, Francesco ;
Del Maschio, Alessandro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) :550-557
[8]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[9]   Assessment of diffusion tensor imaging metrics in differentiating low-grade from high-grade gliomas [J].
El-Serougy, Lamiaa ;
Razek, Ahmed Abdel Khalek Abdel ;
Ezzat, Amani ;
Eldawoody, Hany ;
El-Morsy, Ahmad .
NEURORADIOLOGY JOURNAL, 2016, 29 (05) :400-407
[10]   The 2005 International Society of Urological Pathology (ISUP) Consensus Conference on Gleason Grading of Prostatic Carcinoma [J].
Epstein, JI ;
Allsbrook, WC ;
Amin, MB ;
Egevad, LL ;
Bastacky, S ;
Beltrán, AL ;
Berner, A ;
Billis, A ;
Boccon-Gibod, L ;
Cheng, L ;
Civantos, F ;
Cohen, C ;
Cohen, MB ;
Datta, M ;
Davis, C ;
Delahunt, B ;
Delprado, W ;
Eble, JN ;
Foster, CS ;
Furusato, M ;
Gaudin, PB ;
Grignon, DJ ;
Humphrey, PA ;
Iczkowski, KA ;
Jones, EC ;
Lucia, S ;
McCue, PA ;
Nazeer, T ;
Oliva, E ;
Pan, CC ;
Pizov, G ;
Reuter, V ;
Samaratunga, H ;
Sebo, T ;
Sesterhenn, I ;
Shevchuk, M ;
Srigley, JR ;
Suzigan, S ;
Takahashi, H ;
Tamboli, P ;
Tan, PH ;
Têtu, B ;
Tickoo, S ;
Tomaszewski, JE ;
Troncoso, P ;
Tsuzuki, T ;
True, LD ;
van der Kwast, T ;
Wheeler, TM ;
Wojno, KJ .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 2005, 29 (09) :1228-1242