Quality of EHR data extractions for studies of preterm birth in a tertiary care center: guidelines for obtaining reliable data

被引:32
|
作者
Knake, Lindsey A. [1 ]
Ahuja, Monika [3 ]
McDonald, Erin L. [1 ]
Ryckman, Kelli K. [2 ]
Weathers, Nancy [1 ]
Burstain, Todd [3 ]
Dagle, John M. [1 ]
Murray, Jeffrey C. [1 ]
Nadkarni, Prakash [3 ]
机构
[1] Univ Iowa Hosp & Clin, Dept Pediat, 200 Hawkins Dr,276 MRF, Iowa City, IA 52240 USA
[2] Univ Iowa, Dept Epidemiol, Iowa City, IA USA
[3] Univ Iowa, Inst Clin & Translat Sci, Iowa City, IA USA
来源
BMC PEDIATRICS | 2016年 / 16卷
基金
美国国家卫生研究院;
关键词
Prematurity; Neonatology; Bioinformatics; Data quality; Quality assurance; PEDs data registry; EHR and manual chart abstraction comparison; EHR vs. Manual chart abstraction; and difference in data quality; ELECTRONIC HEALTH RECORDS; CLINICAL-RESEARCH;
D O I
10.1186/s12887-016-0592-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The use of Electronic Health Records (EHR) has increased significantly in the past 15 years. This study compares electronic vs. manual data abstractions from an EHR for accuracy. While the dataset is limited to preterm birth data, our work is generally applicable. We enumerate challenges to reliable extraction, and state guidelines to maximize reliability. Methods: An Epic (TM) EHR data extraction of structured data values from 1,772 neonatal records born between the years 2001-2011 was performed. The data were directly compared to a manually-abstracted database. Specific data values important to studies of perinatology were chosen to compare discrepancies between the two databases. Results: Discrepancy rates between the EHR extraction and the manual database were calculated for gestational age in weeks (2.6 %), birthweight (9.7 %), first white blood cell count (3.2 %), initial hemoglobin (11.9 %), peak total and direct bilirubin (11.4 % and 4.9 %), and patent ductus arteriosus (PDA) diagnosis (12.8 %). Using the discrepancies, errors were quantified in both datasets using chart review. The EHR extraction errors were significantly fewer than manual abstraction errors for PDA and laboratory values excluding neonates transferred from outside hospitals, but significantly greater for birth weight. Reasons for the observed errors are discussed. Conclusions: We show that an EHR not modified specifically for research purposes had discrepancy ranges comparable to a manually created database. We offer guidelines to minimize EHR extraction errors in future study designs. As EHRs become more research-friendly, electronic chart extractions should be more efficient and have lower error rates compared to manual abstractions.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] Quality of EHR data extractions for studies of preterm birth in a tertiary care center: guidelines for obtaining reliable data
    Lindsey A. Knake
    Monika Ahuja
    Erin L. McDonald
    Kelli K. Ryckman
    Nancy Weathers
    Todd Burstain
    John M. Dagle
    Jeffrey C. Murray
    Prakash Nadkarni
    BMC Pediatrics, 16
  • [2] Guidelines for Health IT Addressing the Quality of Data in EHR Information Systems
    Badr, Nabil Georges
    HEALTHINF: PROCEEDINGS OF THE 12TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES - VOL 5: HEALTHINF, 2019, : 169 - 181
  • [3] Improving the quality of EHR recording in primary care: a data quality feedback tool
    van der Bij, Sjoukje
    Khan, Nasra
    ten Veen, Petra
    de Bakker, Dinny H.
    Verheij, Robert A.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2017, 24 (01) : 81 - 87
  • [4] Impact of Electronic versus Paper-Based Record in before EHR Implementation on Health Care Professionals' Perceptions of EHR Use, Data Quality, and Data Reuse
    Joukes, Erik
    de Keizerl, Nicolette F.
    de Bruijne, Martine C.
    Abu-Hanna, Ameen
    Cornett, Ronald
    APPLIED CLINICAL INFORMATICS, 2019, 10 (02): : 199 - 209
  • [5] Data quality assessment for studies investigating microplastics and nanoplastics in food products: Are current data reliable?
    Pang, Lihua
    Lin, Qianhui
    Zhao, Shasha
    Zheng, Hao
    Li, Chenguang
    Zhang, Jing
    Sun, Cuizhu
    Chen, Lingyun
    Li, Fengmin
    FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING, 2023, 17 (08)
  • [6] Data quality assessment for studies investigating microplastics and nanoplastics in food products: Are current data reliable?
    Pang Lihua
    Lin Qianhui
    Zhao Shasha
    Zheng Hao
    Li Chenguang
    Zhang Jing
    Sun Cuizhu
    Chen Lingyun
    Li Fengmin
    Frontiers of Environmental Science & Engineering, 2023, 17 (08)
  • [7] Identified themes of interactive visualizations overlayed onto EHR data: an example of improving birth center operating room efficiency
    Stirling, Andrew
    Tubb, Tracy
    Reiff, Emily S.
    Grotegut, Chad A.
    Gagnon, Jennifer
    Li, Weiyi
    Bradley, Gail
    Poon, Eric G.
    Goldstein, Benjamin A.
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2020, 27 (05) : 783 - 787
  • [8] Data quality in diffusion tensor imaging studies of the preterm brain: a systematic review
    Kay Pieterman
    Annemarie Plaisier
    Paul Govaert
    Alexander Leemans
    Maarten H. Lequin
    Jeroen Dudink
    Pediatric Radiology, 2015, 45 : 1372 - 1381
  • [9] Data quality in diffusion tensor imaging studies of the preterm brain: a systematic review
    Pieterman, Kay
    Plaisier, Annemarie
    Govaert, Paul
    Leemans, Alexander
    Lequin, Maarten H.
    Dudink, Jeroen
    PEDIATRIC RADIOLOGY, 2015, 45 (09) : 1372 - 1381
  • [10] Higher Incidence Rates of Hypothyroidism and Late TSH Rise in Preterm Very-Low-Birth-Weight Infants at a Tertiary Care Center
    Tfayli, Hala
    Charafeddine, Lama
    Tamim, Hani
    Saade, Joanne
    Daher, Rose T.
    Yunis, Khalid
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 89 (04): : 224 - 232