A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone

被引:148
作者
Mahajan, RK [1 ]
Kaur, I [1 ]
Lobana, TS [1 ]
机构
[1] Guru Nanak Dev Univ, Dept Chem, Amritsar 143005, Punjab, India
关键词
sensor; mercury(II); potentiometry; thiosemicarbazone;
D O I
10.1016/S0039-9140(02)00473-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new ion-selective PVC membrane electrode based on salicylaldehyde thiosemicarbazone as an ionophore is developed successfully as sensor for mercury(II) ions. The electrode shows excellent potentiometric response characteristics and displays a linear log[Hg2+] versus EMF response over a wide concentration range of 1.778 x 10(-6)-1.0 x 10(-1) M with Nernstian slope of 29 mV per decade with the detection limit of 1.0 x 10(-6) M. The response time of the electrode is less than 30 s and the membrane electrode operates well in the pH range of 1.0-3.0. The lifetime of the sensor is about 2 months. The electrode shows better selectivity towards Hg2+ ions in comparison with the alkali, alkaline and some heavy metal ions; most of these metal ions do not show significant interference (K-Hg,M(Pot) values of the order of 10(-3)-10(-4)). The present sensor showed comparable or even better performance vis-A-vis similar PVC based ion-selective electrodes reported-in literature. The sensor was also applied as an indicator electrode for potentiometric titration of Hg2+ ions with I- and Cr2O72-. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 105
页数:5
相关论文
共 17 条
[11]   Silver(I) ion selective PVC membrane based on bis-pyridine tetramide macrocycle [J].
Mahajan, RK ;
Parkash, O .
TALANTA, 2000, 52 (04) :691-693
[12]   Silver(I) ion-selective membrane based on Schiff base-p-tert-butylcalix[4]arene [J].
Mahajan, RK ;
Kumar, M ;
Sharma, V ;
Kaur, I .
ANALYST, 2001, 126 (04) :505-507
[13]   General description of the simultaneous response of potentiometric ionophore-based sensors to ions of different charge [J].
Nägele, M ;
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1041-1048
[14]   LEAD(II) ION-SELECTIVE ELECTRODES BASED ON CROWN ETHERS [J].
SHEEN, SR ;
SHIH, JS .
ANALYST, 1992, 117 (11) :1691-1695
[15]   DETERMINATION OF LEAD USING A POLY(VINYL CHLORIDE)-BASED CROWN-ETHER MEMBRANE [J].
SRIVASTAVA, SK ;
GUPTA, VK ;
JAIN, S .
ANALYST, 1995, 120 (02) :495-498
[16]   PVC-based 2,2,2-cryptand sensor for zinc ions [J].
Srivastava, SK ;
Gupta, VK ;
Jain, S .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1272-1275
[17]   DESIGN AND SYNTHESIS OF HIGHLY SELECTIVE IONOPHORES FOR LITHIUM ION BASED ON 14-CROWN-4 DERIVATIVES FOR AN ION-SELECTIVE ELECTRODE [J].
SUZUKI, K ;
YAMADA, H ;
SATO, K ;
WATANABE, K ;
HISAMOTO, H ;
TOBE, Y ;
KOBIRO, K .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3404-3410