Comparison of anterograde versus retrograde percutaneous screw fixation of anterior column acetabular fractures

被引:12
|
作者
Peng, Ye [1 ]
Zhang, Lihai [1 ]
Min, William [2 ]
Tang, Peifu [1 ]
机构
[1] Gen Hosp Chinese Peoples Liberat Army, Dept Orthopaed Surg, 28 Fu Xing Rd, Beijing 100853, Peoples R China
[2] Gwinnett Med Ctr, Hughston Clin, 631 Profess Dr,Suite 170, Lawrenceville, GA 30046 USA
关键词
Anterior column; Percutaneous; Acetabulum; STABILIZATION; OLDER;
D O I
10.1007/s11548-015-1308-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Percutaneous screw fixation is an effective technique in addressing minimally displaced anterior column acetabular fractures. The aim of this study is to evaluate the ease of percutaneous screw insertion for acetabular anterior column fracture, as it pertains to anterograde versus retrograde insertion techniques. From 2009 to 2013, CT imaging from 30 adult volunteers (15 males, 15 females) without history of pelvic disruption and/or morphologic abnormalities were evaluated. From these images, virtual 3D pelvic models were generated. The differences area of screw starting points, limitation position of anterior column screws, and range of screw directions were analyzed. We found in our analysis that anterograde and retrograde had not only variations in their starting points, but differences in areas of insertion. Typically, anterograde portals have a larger area for insertion. Additionally, given the limitations we noted in screw position and the severity of the acetabular fractures, this will allow the treating surgeon to determine the most optimal technique for percutaneous anterior column screw fixation. Results In our analysis, we found two areas for effective percutaneous anterograde insertion and one area for effective retrograde insertion. They both possess geometries with different shapes. Additionally, the area of anterograde insertion is larger than the retrograde area of insertion. The limitations in screw positions were shown in the AP, inlet, outlet, iliac oblique, obturator oblique, and lateral views. The direction range between superior and inferior and between medial and lateral were measured and recorded. In area of anterograde, the angle between the superior and inferior limits was 29.2. +/- 2.7., while the angle limit between medial and lateral was 18.5. +/- 1.8.. In area of retrograde, the angle between the superior and inferior limits was 8.32 degrees +/- 1.3 degrees, while the angle limit between medial and lateral was 7.5 degrees +/- 0.8 degrees.
引用
收藏
页码:635 / 639
页数:5
相关论文
共 50 条
  • [11] Percutaneous Retrograde Posterior Column Acetabular Fixation: Is the Sciatic Nerve Safe? A Cadaveric Study
    Azzam, Khalid
    Siebler, Justin
    Bergmann, Karl
    Daccarett, Miguel
    Mormino, Matthew
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (01) : 37 - 40
  • [12] Percutaneous fixation of acetabular fractures
    Caviglia, Horacio
    Mejail, Adrian
    Landro, Maria Eulalia
    Vatani, Nosratolah
    EFORT OPEN REVIEWS, 2018, 3 (05): : 326 - 334
  • [13] Management of odontoid fractures with percutaneous anterior odontoid screw fixation
    Chi, Yong-Long
    Wang, Xiang-Yang
    Xu, Hua-Zi
    Lin, Yan
    Huang, Qi-Shan
    Mao, Fang-Min
    Ni, Wen-Fei
    Wang, Sheng
    Dai, Li-Yang
    EUROPEAN SPINE JOURNAL, 2007, 16 (08) : 1157 - 1164
  • [14] Management of odontoid fractures with percutaneous anterior odontoid screw fixation
    Yong-Long Chi
    Xiang-Yang Wang
    Hua-Zi Xu
    Yan Lin
    Qi-Shan Huang
    Fang-Min Mao
    Wen-Fei Ni
    Sheng Wang
    Li-Yang Dai
    European Spine Journal, 2007, 16 : 1157 - 1164
  • [15] Fluoroscopically guided acetabular posterior column screw fixation via an anterior approach
    Krappinger, Dietmar
    Schwendinger, Peter
    Lindtner, Richard A.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2019, 31 (06): : 503 - 511
  • [16] A quantitative anatomic study of plate–screw fixation of the acetabular anterior column through an anterior approach
    Wang Xian-quan
    Cai Jin-fang
    Cao Xue-cheng
    Mu Wei-dong
    Zhang Wei
    Sun Shui
    Zhang Jin-lu
    Wang Jian
    Li Wei
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 257 - 262
  • [17] Double column acetabular fractures fixation using a novel dynamic anterior plate-screw system: A biomechanical analysis
    Wu, Haiyang
    Song, Chengjing
    Shang, Ranran
    Shao, Qipeng
    Liu, Ximing
    Zhang, Hongqi
    Cai, Xianhua
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (03): : 407 - 413
  • [18] Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus
    Zhang, Li-hai
    Zhang, Li-cheng
    Si, Qing-hua
    Gao, Yuan
    Su, Xiu-yun
    Zhao, Zhe
    Tang, Pei-fu
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [19] Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus
    Li-hai Zhang
    Li-cheng Zhang
    Qing-hua Si
    Yuan Gao
    Xiu-yun Su
    Zhe Zhao
    Pei-fu Tang
    BMC Musculoskeletal Disorders, 17
  • [20] The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study
    Liu, Zhao-jie
    Gu, Ya
    Jia, Jian
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)