Ratiometric Fluorescent Lateral Flow Immunoassay for Point-of-Care Testing of Acute Myocardial Infarction

被引:221
作者
Wang, Jing [1 ]
Jiang, Chenxing [1 ]
Jin, Jiening [1 ]
Huang, Liang [1 ]
Yu, Wenbo [3 ]
Su, Bin [2 ]
Hu, Jun [1 ]
机构
[1] Zhejiang Univ Technol, Coll Chem Engn, Hangzhou 310014, Peoples R China
[2] Zhejiang Univ, Dept Chem, Inst Analyt Chem, Hangzhou 310058, Peoples R China
[3] China Agr Univ, Coll Vet Med, Beijing Key Lab Detect Technol Anim Derived Food, Beijing Lab Food Qual & Safety, Beijing 100193, Peoples R China
基金
中国国家自然科学基金;
关键词
H-FABP; immunoassays; point-of-care; ratiometric fluorescence; visual detection; ACUTE CORONARY SYNDROMES; QUANTITATIVE DETECTION; QUANTUM DOTS; IMMUNOCHROMATOGRAPHIC ASSAY; VISUAL DETECTION; TASK-FORCE; REAL-TIME; NANOPARTICLES; NANOSPHERES; GUIDELINES;
D O I
10.1002/anie.202103458
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We report the development of a highly sensitive ratiometric fluorescent lateral flow immunoassay (RFLFIA) strip for rapid and accurate detection of acute myocardial infarction biomarker, namely heart-type fatty acid binding protein (H-FABP). The RFLFIA strip works in terms of ratiometric change of fluorescence signal, arising from blending of fluorescence emitted by two composite nanostructures conjugated to capture and probe antibodies and inner filter effect of gold nanoparticles. In conjunction with using custom smartphone-based analytical device and tonality analysis, quantitative detection of H-FABP was achieved with a low limit of detection at 0.21 ng mL(-1). The RFLFIA strip can generate a visually distinguishable green-to-red color change around the threshold concentration of H-FABP (6.2 ng mL(-1)), thus allowing the semi-quantitative diagnosis by the naked eye.
引用
收藏
页码:13042 / 13049
页数:8
相关论文
共 65 条
[1]   2012 ACCF/AHA Focused Update Incorporated Into the ACCF/AHA 2007 Guidelines for the Management of Patients With Unstable Angina/Non-ST-Elevation Myocardial Infarction [J].
Anderson, Jeffrey L. ;
Adams, Cynthia D. ;
Antman, Elliott M. ;
Bridges, Charles R. ;
Califf, Robert M. ;
Casey, Donald E., Jr. ;
Chavey, William E., II ;
Fesmire, Francis M. ;
Hochman, Judith S. ;
Levin, Thomas N. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Theroux, Pierre ;
Wenger, Nanette K. ;
Wright, R. Scott ;
Jneid, Hani ;
Anderson, Jeffrey L. ;
Wright, R. Scott ;
Adams, Cynthia D. ;
Bridges, Charles R. ;
Casey, Donald E., Jr. ;
Ettinger, Steven M. ;
Fesmire, Francis M. ;
Ganiats, Theodore G. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Philippides, George J. ;
Theroux, Pierre ;
Wenger, Nanette K. ;
Anderson, Jeffrey L. ;
Jacobs, Alice K. ;
Halperin, Jonathan L. ;
Albert, Nancy M. ;
Creager, Mark A. ;
DeMets, David ;
Ettinger, Steven M. ;
Guyton, Robert A. ;
Hochman, Judith S. ;
Kushner, Frederick G. ;
Ohman, E. Magnus ;
Stevenson, William ;
Yancy, Clyde W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (23) :E179-E347
[2]  
[Anonymous], 2019, ANGEW CHEM, V131, P450
[3]  
[Anonymous], 2020, ANGEW CHEM, V132, P3155
[4]  
[Anonymous], 2012, ANGEW CHEM, V124, P7297
[5]  
[Anonymous], 2018, ANGEW CHEM, V130, P7507
[6]  
[Anonymous], 2017, ANGEW CHEM, V129, P5906
[7]  
[Anonymous], 2020, Angew. Chem, V132, P24071
[8]  
Bassand JP, 2007, EUR HEART J, V28, P1598, DOI 10.1093/eurheartj/ehm161
[9]   Door-to-balloon time with primary percutaneous coronary intervention for acute myocardial infarction impacts late cardiac mortality in high-risk patients and patients presenting early after the onset of symptoms [J].
Brodie, BR ;
Hansen, C ;
Stuckey, TD ;
Richter, S ;
VerSteeg, DS ;
Gupta, N ;
Downey, WE ;
Pulsipher, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (02) :289-295
[10]   Use of the Hue Parameter of the Hue, Saturation, Value Color Space As a Quantitative Analytical Parameter for Bitonal Optical Sensors [J].
Cantrell, K. ;
Erenas, M. M. ;
de Orbe-Paya, I. ;
Capitan-Vallvey, L. F. .
ANALYTICAL CHEMISTRY, 2010, 82 (02) :531-542