Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time-of-flight and LTQ-Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro - amitriptyline and verapamil as model compounds

被引:79
作者
Rousu, Timo [1 ,2 ]
Herttuainen, Jukka [3 ]
Tolonen, Ari [1 ]
机构
[1] Novamass Ltd, Medipolis Ctr, Oulu 90220, Finland
[2] Univ Oulu, Dept Chem, Oulu 90014, Finland
[3] Orion Pharma, Espoo 02101, Finland
关键词
BIOTRANSFORMATION; ACQUISITION; THROUGHPUT; INDINAVIR; SYSTEM; DEFECT; URINE;
D O I
10.1002/rcm.4465
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography in combination with mass spectrometry (LC/MS) is a superior analytical technique for metabolite profiling and identification studies performed in drug discovery and development laboratories. In the early phase of drug discovery the analytical approach should be both time- and cost-effective, thus providing as much data as possible with only one visit to the laboratory, without the need for further experiments. Recent developments in mass spectrometers have created a situation where many different mass spectrometers are available for the task, each with their specific strengths and drawbacks. We compared the metabolite screening properties of four main types of mass spectrometers used in analytical laboratories, considering both the ability to detect the metabolites and provide structural information, as well as the issues related to time consumption in laboratory and thereafter in data processing. Human liver microsomal incubations with amitriptyline and verapamil were used as test samples, and early-phase 'one lab visit only' approaches were used with all instruments. In total, 28 amitriptyline and 69 verapamil metabolites were found and tentatively identified. Time-of-flight mass spectrometry (TOFMS) was the only approach detecting all of them, shown to be the most suitable instrument for elucidating as comprehensive metabolite profile as possible leading also to lowest overall time consumption together with the LTQ-Orbitrap approach. The latter however suffered from lower detection sensitivity and false negatives, and due to slow data acquisition rate required slower chromatography. Approaches with triple quadrupole mass spectrometry (QqQ) and hybrid linear ion trap triple quadrupole mass spectrometry (Q-Trap) provided the highest amount of fragment ion data for structural elucidation, but, in addition to being unable to produce very high-important accurate mass data, they suffered from many false negatives, and especially with the QqQ, from very high overall time consumption. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:939 / 957
页数:19
相关论文
共 35 条
[1]   Integration of knowledge-based metabolic predictions with liquid chromatography data-dependent tandem mass spectrometry for drug metabolism studies: Application to studies on the biotransformation of Indinavir [J].
Anari, MR ;
Sanchez, RI ;
Bakhtiar, R ;
Franklin, RB ;
Baillie, TA .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :823-832
[2]   The metabolic fate of amitriptyline, nortriptyline and amitriptylinoxide in man [J].
Breyer-Pfaff, U .
DRUG METABOLISM REVIEWS, 2004, 36 (3-4) :723-746
[3]   Pharmaceutical metabolite profiling using quadrupole/ion mobility spectrometry/time-of-flight mass spectrometry [J].
Chan, Eric C. Y. ;
New, Lee Sun ;
Yap, Chun Wei ;
Goh, Lin Tang .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (03) :384-394
[4]   Metabolism:: A bottleneck in in vitro toxicological test development -: The report and recommendations of ECVAM workshop 54 [J].
Coecke, S ;
Ahr, H ;
Blaauboer, BJ ;
Bremer, S ;
Casati, S ;
Castell, J ;
Combes, R ;
Corvi, R ;
Crespi, CL ;
Cunningham, ML ;
Elaut, G ;
Eletti, B ;
Freidig, A ;
Gennari, A ;
Ghersi-Egea, JF ;
Guillouzo, A ;
Hartung, T ;
Hoet, P ;
Ingelman-Sundberg, M ;
Munn, S ;
Janssens, W ;
Ladstetter, B ;
Leahy, D ;
Long, A ;
Meneguz, A ;
Monshouwer, M ;
Morath, S ;
Nagelkerke, F ;
Pelkonen, O ;
Ponti, J ;
Prieto, P ;
Richert, L ;
Sabbioni, E ;
Schaack, B ;
Steiling, W ;
Testai, E ;
Vericat, JA ;
Worth, A .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2006, 34 (01) :49-84
[5]   Extracting metabolite ions out of a matrix background by combined mass defect, neutral loss and isotope filtration [J].
Cuyckens, Filip ;
Hurkmans, Rob ;
Castro-Perez, Jose M. ;
Leclercq, Laurent ;
Mortishire-Smith, Russell J. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (02) :327-332
[6]  
*FDA GUID IND, 2008, SAF TEST DRUG MET
[7]   A new linear ion trap mass spectrometer [J].
Hager, JW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :512-526
[8]   Feasibility of different mass spectrometric techniques and programs for automated metabolite profiling of tramadol in human urine [J].
Hakala, Kati S. ;
Kostiainen, Risto ;
Ketola, Raimo A. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (14) :2081-2090
[9]   Automated assignment of high-resolution collisionally activated dissociation mass spectra using a systematic bond disconnection approach [J].
Hill, AW ;
Mortishire-Smith, RJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) :3111-3118
[10]   Triple quadrupole linear ion trap mass spectrometer for the analysis of small molecules and macromolecules [J].
Hopfgartner, G ;
Varesio, E ;
Tschäppät, V ;
Grivet, C ;
Bourgogne, E ;
Leuthold, LA .
JOURNAL OF MASS SPECTROMETRY, 2004, 39 (08) :845-855