Brain shift estimation in image-guided neurosurgery using 3-D ultrasound

被引:99
作者
Letteboer, MMJ
Willems, PWA
Viergever, MA
Niessen, WJ
机构
[1] Univ Utrecht, Med Ctr, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Dept Neurosurg, NL-3584 CX Utrecht, Netherlands
关键词
brain shift; computer-assisted surgery; neuronavigation; neurosurgery; 3-D ultrasound;
D O I
10.1109/TBME.2004.840186
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intraoperative brain deformation is one of the most important causes affecting the overall accuracy of image-guided neurosurgical procedures. One option for correcting for this deformation is to acquire three-dimensional (3-D) ultrasound data during the operation and use this data to update the information provided by the preoperatively acquired MR data. For 12 patients 3-D ultrasound images have been reconstructed from freehand sweeps acquired during neurosurgical procedures. Ultrasound data acquired prior to and after opening the dura, but prior to surgery, have been quantitatively compared to the preoperatively acquired MR data to estimate the rigid component of brain shift at the first stages of surgery. Prior to opening the dura the average brain shift measured was 3.0 mm parallel to the direction of gravity, with a maximum of 7.5 mm, and 3.9 mm perpendicular to the direction of gravity, with a maximum of 8.2 mm. After opening the dura the shift increased on average 0.2 mm parallel to the direction of gravity and 1.4 mm perpendicular to the direction of gravity. Brain shift can, be detected by acquiring 3-D ultrasound data during image-guided neurosurgery. Therefore, it can be used as a basis for correcting image data and preoperative planning for intraoperative deformations.
引用
收藏
页码:268 / 276
页数:9
相关论文
共 52 条
[11]   Preliminary clinical experience with intraoperative stereotactic ultrasound imaging [J].
Giorgi, C ;
Casolino, DS .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 68 (1-4) :54-58
[12]  
GOBBI DG, 2002, LECT NOTES COMPUTER, V2489, P15
[13]   SonoWand, an ultrasound-based neuronavigation system [J].
Gronningsaeter, A ;
Kleven, A ;
Ommedal, S ;
Aarseth, TE ;
Lie, T ;
Lindseth, F ;
Lango, T ;
Unsgard, G .
NEUROSURGERY, 2000, 47 (06) :1373-1379
[14]   Biomechanical modeling of the human head for physically based, nonrigid image registration [J].
Hagemann, A ;
Rohr, K ;
Stiehl, HS ;
Spetzger, U ;
Gilsbach, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :875-884
[15]   Use of intraoperative ultrasound for localizing tumors and determining the extent of resection: A comparative study with magnetic resonance imaging [J].
Hammoud, MA ;
Ligon, BL ;
ElSouki, R ;
Shi, WM ;
Schomer, DF ;
Sawaya, R .
JOURNAL OF NEUROSURGERY, 1996, 84 (05) :737-741
[16]   Measurement and analysis of brain deformation during neurosurgery [J].
Hartkens, T ;
Hill, DLG ;
Castellano-Smith, AD ;
Hawkes, DJ ;
Maurer, CR ;
Martin, AJ ;
Hall, WA ;
Liu, H ;
Truwit, CL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (01) :82-92
[17]   Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration [J].
Hata, N ;
Dohi, T ;
Iseki, H ;
Takakura, K .
NEUROSURGERY, 1997, 41 (03) :608-613
[18]   Three-dimensional optical flow method for measurement of volumetric brain deformation from intraoperative MR images [J].
Hata, N ;
Nabavi, A ;
Wells, WM ;
Warfield, SK ;
Kikinis, R ;
Black, PM ;
Jolesz, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (04) :531-538
[19]  
Hernes TAN, 2003, MINIM INVAS NEUROSUR, V46, P129
[20]   Measurement of intraoperative brain surface deformation under a craniotomy [J].
Hill, DLG ;
Maurer, CR ;
Maciunas, RJ ;
Barwise, JA ;
Fitzpatrick, JM ;
Wang, MY .
NEUROSURGERY, 1998, 43 (03) :514-526