Evaluation of anterior segment parameter changes using the Pentacam after uneventful phacoemulsification

被引:43
作者
Doganay, Selim [1 ]
Bozgul Firat, Penpegul
Emre, Sinan
Yologlu, Saim [2 ]
机构
[1] Inonu Univ, Sch Med, Turgut Ozal Med Ctr, Dept Ophthalmol, TR-44280 Malatya, Turkey
[2] Inonu Univ, Sch Med, Dept Biostat, TR-44280 Malatya, Turkey
关键词
anterior segment parameters; cataract surgery; Pentacam; phacoemulsification; INTRAOCULAR-LENS IMPLANTATION; OPTICAL COHERENCE TOMOGRAPHY; CLEAR CORNEAL PHACOEMULSIFICATION; ANGLE-CLOSURE GLAUCOMA; CHAMBER DEPTH; CATARACT-SURGERY; PRESSURE CONTROL; CELL-DENSITY; EYES; VOLUME;
D O I
10.1111/j.1755-3768.2008.01446.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: This study set out to evaluate the influences of uneventful phacoemulsification on the anterior segment parameters obtained with the Pentacam rotating Scheimpflug camera and intraocular pressure (IOP). Methods: A total of 42 eyes of 34 patients (26 men, eight women) were evaluated preoperatively, and at 1, 3 and 6 months postoperatively with the Pentacam. Intraocular pressure was measured with the Goldmann applanation tonometer. The non-parametric paired t-test was used to compare preoperative and 1-, 3- and 6-month postoperative measurements of anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA) width, central corneal thickness (CCT), the central 3-, 5- and 7-mm corneal volume (CV), pupil size, and IOP. Pearson's correlation test was used to evaluate the relationships between IOP and ACD, ACV and ACA width. Results: The differences between ACD, ACV, ACA and IOP values taken preoperatively and those taken postoperatively at 1, 3 and 6 months were statistically significant (p < 0.05). The differences between CCT, central 3-, 5- and 7-mm CV, and pupil size measurements taken preoperatively and those taken postoperatively at 1, 3 and 6 months were not statistically significant (p > 0.05). The decrease in IOP was not correlated with the changes in ACD, ACV and ACA (p > 0.05). Conclusions: Uneventful phacoemulsification significantly reduced IOP, increased ACD and ACV, and widened the ACA. However, alterations in CV, CCT and pupil size values were not statistically significant. Alterations in ACD, ACV, ACA and IOP remain stable after the first month of surgery.
引用
收藏
页码:601 / 606
页数:6
相关论文
共 35 条
[1]  
ALPAR JJ, 1985, J GLAUCOMA, V5, P241
[2]   Anterior chamber depth, iridocorneal angle width, and intraocular pressure changes after uneventful phacoemulsification in eyes without glaucoma and with open iridocorneal angles [J].
Altan, C ;
Bayraktar, S ;
Altan, T ;
Eren, H ;
Yilmaz, OF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04) :832-838
[3]   Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry [J].
Barkana, Y ;
Gerber, Y ;
Elbaz, U ;
Schwartz, S ;
Ken-Dror, G ;
Avni, I ;
Zadok, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1729-1735
[4]   CORNEAL ENDOTHELIAL DAMAGE ASSOCIATED WITH PHACOEMULSIFICATION [J].
BINDER, PS ;
STERNBERG, H ;
WICKHAM, MG ;
WORTHEN, DM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 82 (01) :48-54
[5]   Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment [J].
Dada, Tanuj ;
Sihota, Ramanjit ;
Gadia, Ritu ;
Aggarwal, Anand ;
Mandal, Subrata ;
Gupta, Viney .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :837-840
[6]   Anterior segment optical coherence tomography for evaluation of changes in anterior chamber angle and depth after intraocular lens implantation in eyes with glaucoma [J].
Dawczynski, J. ;
Koenigsdoerffer, E. ;
Augsten, R. ;
Strobel, J. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (03) :363-367
[7]   Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system [J].
Emre, Sinan ;
Doganay, Selim ;
Yologlu, Saim .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10) :1708-1712
[8]   Pupil size before and after phacoemulsification in nondiabetic and diabetic patients [J].
Hayashi, K ;
Hayashi, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (12) :2543-2550
[9]   Changes in anterior chamber angle width and depth after intraocular lens implantation in eyes with glaucoma [J].
Hayashi, K ;
Hayashi, H ;
Nakao, F ;
Hayashi, F .
OPHTHALMOLOGY, 2000, 107 (04) :698-703
[10]   Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations [J].
Holladay, JT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1356-1370