Spatial resolution of x-ray tomosynthesis in relation to computed tomography for coronal/sagittal images of the knee

被引:21
作者
Flynn, Michael J. [1 ]
McGee, Robert [1 ]
Blechinger, Joseph [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiol, Detroit, MI USA
来源
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2007年 / 6510卷
关键词
resolution; tomosynthesis; computed tomography; knee;
D O I
10.1117/12.713805
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We consider in this report, a tomosynthesis (TS) system utilizing a recently developed Selenium flat panel detector (Shimadzu Safire II) capable of acquiring 30 pulsed frames per second (fps) with precise geometric registration to a moving gantry. The reconstructed TS resolution achieved with this system is reported in relation to the resolution obtained with modern volumetric computed tomography (vCT) systems. Computed tomography resolution is assessed using a sphere phantom. To, describe the resolution of coronal/sagittal re-formatted planes, we average the transverse and axial response to express typical vCT performance as 1.00 mm (FWHM PISF) and 0.83 cycles/mm (10% MTF). Tomosynthesis response is assessed using a wire phantom. To describe the resolution of the coronal/sagittal TS images, we use the FWHM of the LSF and the frequency at 20% of the peak spatial frequency response to express typical TS performance as 2.41 mm (FWHM LSF) and 2.62 cycles/mm (20% Peak). Cadaver images confirm that the TS resolution is about 3 times better than that for vCT systems. On the other hand, the TS slice sensitivity of 3. mm is about 3 times larger than vCT resolution (FWHM LSF).
引用
收藏
页数:9
相关论文
共 14 条
[1]   SELF-MASKING SUBTRACTION TOMOSYNTHESIS [J].
CHAKRABORTY, DP ;
YESTER, MV ;
BARNES, GT ;
LAKSHMINARAYANAN, AV .
RADIOLOGY, 1984, 150 (01) :225-229
[2]   Digital tomosynthesis of hand joints for arthritis assessment [J].
Duryea, J ;
Dobbins, JT ;
Lynch, JA .
MEDICAL PHYSICS, 2003, 30 (03) :325-333
[3]   DIGITAL TOMOGRAPHY - DESCRIPTION AND PRELIMINARY CLINICAL-EXPERIENCE [J].
FRIEDENBERG, RM ;
LIGHTFOOTE, JB ;
WANG, SP ;
SMOLIN, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (03) :639-643
[4]   Super-global distortion correction for a rotational C-arm x-ray image intensifier [J].
Liu, RR ;
Rudin, S ;
Bednarek, DR .
MEDICAL PHYSICS, 1999, 26 (09) :1802-1810
[5]   DIGITAL TOMOSYNTHESIS - TECHNIQUE FOR ELECTRONIC RECONSTRUCTIVE TOMOGRAPHY [J].
MARAVILLA, KR ;
MURRY, RC ;
HORNER, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (03) :497-502
[6]   Recent advances in chest radiography [J].
McAdams, H. Page ;
Samei, Ehsan ;
Dobbins, James, III ;
Tourassi, Georgia D. ;
Ravin, Carl E. .
RADIOLOGY, 2006, 241 (03) :663-683
[7]  
MERTELMEIER T, 2006, MED IMAGING 2006 PHY
[8]  
MORITA E, 2003, RADIOGRAPHIC APPARAT, P27
[9]   Digital Tomosynthesis in breast imaging [J].
Niklason, LT ;
Christian, BT ;
Niklason, LE ;
Kopans, DB ;
Castleberry, DE ;
OpsahlOng, BH ;
Landberg, CE ;
Slanetz, PJ ;
Giardino, AA ;
Moore, R ;
Albagli, D ;
DeJule, MC ;
Fitzgerald, PF ;
Fobare, DF ;
Giambattista, BW ;
Kwasnick, RF ;
Liu, JQ ;
Lubowski, SJ ;
Possin, GE ;
Richotte, JF ;
Wei, CY ;
Wirth, RF .
RADIOLOGY, 1997, 205 (02) :399-406
[10]  
OIKAWA S, 2003, RADIOGRAPHIC APPARAT, V24